Biomechanical Properties of the Cornea Measured With the Dynamic Scheimpflug Analyzer in Young Healthy Adults

被引:5
|
作者
Lee, Hun [1 ,2 ]
Kang, David Sung Yong [3 ]
Ha, Byoung Jin [3 ]
Choi, Jin Young [2 ]
Kim, Eung Kweon [2 ,4 ]
Seo, Kyoung Yul [2 ]
Kim, Ha Yan [5 ]
Kim, Tae-im [2 ]
机构
[1] Catholic Kwandong Univ, Coll Med, Int St Marys Hosp, Dept Ophthalmol, Inchon, South Korea
[2] Yonsei Univ, Coll Med, Inst Vis Res, Dept Ophthalmol, Seoul, South Korea
[3] Eyereum Eye Clin, Seoul, South Korea
[4] Yonsei Univ, Coll Med, Corneal Dystrophy Res Inst, Dept Ophthalmol, Seoul, South Korea
[5] Yonsei Univ, Coll Med, Biostat Collaborat Unit, Seoul, South Korea
关键词
corneal biomechanical property; dynamic Scheimpflug analyzer; young healthy adults; normal value database; OCULAR RESPONSE ANALYZER; IN-SITU KERATOMILEUSIS; INTRAOCULAR-PRESSURE; CROSS-LINKING; NORMAL EYES; PARAMETERS; KERATOCONUS; NONCONTACT;
D O I
10.1097/ICO.0000000000001001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the biomechanical properties of the cornea using the dynamic Scheimpflug analyzer in young healthy adults. Methods: This prospective cross-sectional population study included 944 eyes of 472 participants aged 20 to 40 years. Participants underwent ophthalmic investigations, including evaluation of biomechanical properties of the cornea using the dynamic Scheimpflug analyzer, manifest refraction, and measurements of keratometric values by autokeratometry, intraocular pressure (IOP) by noncontact tonometer, central corneal thickness (CCT) by ultrasound, and white-to-white distance by Scheimpflug tomography. Statistical analyses included determination of the reference interval with a bootstrapping method, linear quantile mixed-effects model, and Spearman correlation analysis between the corneal biomechanical parameters and other variables (age, manifest refraction spherical equivalent, CCT, IOP, white-to-white, and keratometric values). Results: The 90% CIs of all corneal biomechanical parameters demonstrated that the ranges of the 90% CIs for the reference data were almost identical with and without bootstrapping. Quantile regression to determine the fifth, 50th, and 95th percentiles of each corneal biomechanical parameter supported the findings from the nonparametric method with the 90% CIs. Correlation analysis showed significant correlations between the parameters and variables, but there was a relatively high Spearman correlation coefficient in the case of the correlations with the CCT and IOP. Conclusions: Using data from a large population of young healthy adults, we developed a database of normal values for multiple corneal biomechanical parameters obtained from the dynamic Scheimpflug analyzer. We conclude that the biomechanical properties of the cornea are influenced by the CCT and IOP.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [21] Identification of Biomechanical Properties of the Cornea: The Ocular Response Analyzer
    Terai, Naim
    Raiskup, Frederik
    Haustein, Michael
    Pillunat, Lutz E.
    Spoerl, Eberhard
    CURRENT EYE RESEARCH, 2012, 37 (07) : 553 - 562
  • [22] Measurement of Orbital Biomechanical Properties in Patients with Thyroid Orbitopathy Using the Dynamic Scheimpflug Analyzer (Corvis ST)
    Leszczynska, Anna
    Moehler, Karolin
    Spoerl, Eberhard
    Ramm, Lisa
    Herber, Robert
    Pillunat, Lutz E.
    Terai, Naim
    CURRENT EYE RESEARCH, 2018, 43 (03) : 289 - 292
  • [23] Factors Associated With Corneal Deformation Responses Measured With a Dynamic Scheimpflug Analyzer
    Miki, Atsuya
    Maeda, Naoyuki
    Ikuno, Yasushi
    Asai, Tomoko
    Hara, Chikako
    Nishida, Kohji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (01) : 538 - 544
  • [24] Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer
    Kotecha, Aachal
    Elsheikh, Ahmed
    Roberts, Cynthia R.
    Zhu, Haogang
    Garway-Heath, David F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (12) : 5337 - 5347
  • [25] Biomechanical properties of the cornea measured by the Ocular Response Analyzer and their association with intraocular pressure and the central corneal curvature
    Franco, Sandra
    Lira, Madalena
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (06) : 469 - 475
  • [26] Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer
    Oddone, F
    Kotecha, A
    Shewry, J
    White, ET
    Garway-Heath, DF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [27] Birefringent properties of the cornea measured by a Mueller type polarimeter in healthy adults and children
    Sobczak, Marcelina
    Asejczyk, Magdalena
    BIOMEDICAL OPTICS EXPRESS, 2021, 12 (12) : 7872 - 7885
  • [28] Evaluation of the biomechanical properties of the cornea in different glaucoma types with Corvis Scheimpflug technology
    Harbiyeli, Ibrahim Inan
    Erdem, Elif
    Uysal, Anil
    Binokay, Hulya
    Yagmur, Meltem
    CUKUROVA MEDICAL JOURNAL, 2022, 47 (01): : 426 - 435
  • [29] Biomechanical properties of the cornea measurement using Scheimpflug noncontact tonometry in aniridia patients
    Wowra, Bogumil
    Dobrowolski, Dariusz
    Tarnawska, Dorota
    Wylegala, Edward
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [30] Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
    Luce, DA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01): : 156 - 162