Corneal regular and irregular astigmatism assessed by Fourier analysis of videokeratography data in normal and pathologic eyes

被引:49
|
作者
Tanabe, T
Tomidokoro, A
Samejima, T
Miyata, K
Sato, M
Kaji, Y
Oshika, T
机构
[1] Univ Tsukuba, Inst Clin Med, Dept Ophthalmol, Tsukuba, Ibaraki 3058575, Japan
[2] Univ Tokyo, Sch Med, Dept Ophthalmol, Tokyo, Japan
[3] Miyata Eye Hosp, Meiwakai Med Fdn, Miyazaki, Japan
[4] Univ Tsukuba, Inst Clin Med, Dept Ophthalmol, Tsukuba, Ibaraki, Japan
关键词
D O I
10.1016/j.ophtha.2003.06.019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess corneal regular and irregular astigmatism using Fourier series harmonic analysis of videokeratography data in normal subjects, as well as in subjects with pathologic and postsurgical conditions. Study Design: Retrospective, case-control study. Participants: Two hundred normal eyes, 58 eyes with keratoconus, 24 eyes with suspect keratoconus, 100 eyes that underwent LASIK, 101 eyes that underwent photorefractive keratectomy (PRK), and 79 eyes that underwent penetrating keratoplasty (PK). Methods: Videokeratography data were decomposed, using Fourier analysis, into spherical power, regular astigmatism, asymmetry, and higher order irregularity. Results: The normal range of the Fourier indices was defined as the mean +/-2xstandard deviation in the normal eyes, which were 40.81-47.13 diopters (D) for spherical power, 0-1.04 D for regular astigmatism, 0.02-0.68 D for asymmetry, and 0.05-0.17 for higher order irregularity. The keratoconus and suspect keratoconus groups showed significantly greater values in all indices than did the normal group (P<0.001 or 0.0001, Mann-Whitney test with Bonferroni correction). Eyes that had undergone LASIK and PRK had significantly smaller spherical power and regular astigmatism (P<0.0001) and significantly larger asymmetry (P<0.0001) than the normal eyes. All indices were significantly greater in the PK group than in the normal group (P<0.0001). Among the eyes tested in this study, eyes with keratoconus had the largest asymmetry, whereas eyes that had undergone PK had the most irregular corneas. Conclusions: The normal range was defined for the corneal irregular astigmatism index (asymmetry and higher order irregularity) to support future studies in this field. Eyes with ocular pathologic and postsurgical conditions were evaluated using the normal range. (C) 2004 by the American Academy of Ophthalmology.
引用
收藏
页码:752 / 757
页数:6
相关论文
共 50 条
  • [31] Comparison of corneal power and astigmatism in normal eyes using 4 different devices
    Han, K. E.
    Lee, H. K.
    Hwang, H. S.
    Shin, M. C.
    [J]. ACTA OPHTHALMOLOGICA, 2014, 92
  • [32] FOURIER-ANALYSIS OF VIDEO-KERATOGRAPHIC DATA - A TOOL FOR SEPARATION OF SPHERICAL, REGULAR ASTIGMATIC AND IRREGULAR ASTIGMATIC CORNEAL POWER COMPONENTS
    HJORTDAL, JO
    ERDMANN, L
    BEK, T
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1995, 15 (03) : 171 - 185
  • [33] Fourier analysis of anterior and posterior corneal surface astigmatism.
    Proano, CE
    Proano, JC
    Azar, DT
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S680 - S680
  • [34] Fourier analysis of corneal irregular astigmatism after small-incision lenticule extraction and transepithelial photorefractive keratectomy: A comparative study
    Ning, Jiliang
    Zhang, Lijun
    [J]. MEDICINE, 2024, 103 (09) : E37340
  • [35] Fourier analysis of irregular astigmatism after implantation of 3 types of intraocular lenses
    Hayashi, K
    Hayashi, H
    Oshika, T
    Hayashi, F
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (10): : 1510 - 1516
  • [36] Correction of irregular and induced regular corneal astigmatism with toric IOL after posterior segment surgery: a case series
    Kolozsvari, Bence L.
    Losonczy, Gergely
    Pasztor, Dorottya
    Fodor, Mariann
    [J]. BMC OPHTHALMOLOGY, 2017, 17 : 1 - 6
  • [37] Correction of irregular and induced regular corneal astigmatism with toric IOL after posterior segment surgery: a case series
    Bence L. Kolozsvári
    Gergely Losonczy
    Dorottya Pásztor
    Mariann Fodor
    [J]. BMC Ophthalmology, 17
  • [38] Vector analysis of corneal astigmatism in cataractous eyes based on IOLMaster 700 biometry
    Langenbucher, Achim
    Wendelstein, Jascha
    Cayless, Alan
    Hoffmann, Peter
    Szentmary, Nora
    [J]. PLOS ONE, 2024, 19 (04):
  • [39] Fourier analysis of videokeratography data: Clinical usefulness in grade I and subclinical keratoconus
    Sideroudi, Haris
    Labiris, Georgios
    Georgatzoglou, Kimon
    Ditzel, Fienke
    Siganos, Charalambos
    Kozobolis, Vassilios
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (05): : 731 - 737
  • [40] Fourier Analysis of Corneal Irregular Astigmatism After Small Incision Lenticule Extraction and Comparison to Femtosecond Laser-Assisted Laser In Situ Keratomileusis
    Sideroudi, Haris
    Sekundo, Walter
    Kozobolis, Vassilios
    Messerschmidt-Roth, Anke
    Lazaridis, Apostolos
    [J]. CORNEA, 2019, 38 (12) : 1536 - 1542