Fourier analysis of videokeratography data: Clinical usefulness in grade I and subclinical keratoconus

被引:13
|
作者
Sideroudi, Haris [1 ]
Labiris, Georgios [1 ,2 ]
Georgatzoglou, Kimon [1 ]
Ditzel, Fienke [4 ]
Siganos, Charalambos [3 ]
Kozobolis, Vassilios [1 ,2 ]
机构
[1] Democritus Univ, Eye Inst Thrace, Iraklion, Greece
[2] Univ Hosp Alexandroupolis, Dept Ophthalmol, Iraklion, Greece
[3] Univ Crete, Inst Vis & Opt, Iraklion, Greece
[4] Univ Groningen, Univ Med Ctr Groningen, Groningen, Netherlands
来源
关键词
FORME-FRUSTE KERATOCONUS; UNILATERAL KERATOCONUS; VISUAL-ACUITY; CORNEAL; ANTERIOR; EYES; KERATOPLASTY; KERATECTOMY; PROGRESSION;
D O I
10.1016/j.jcrs.2016.01.049
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the contribution of Fourier analysis of videokeratographic data in the diagnosis of subclinical keratoconus and keratoconus. SETTING: Eye Institute of Thrace, Democritus University, Alexandroupolis, Greece. DESIGN: Observational case series. METHODS: The following Pentacam-derived parameters, resulting from Fourier decomposition of keratometric data, were evaluated for their diagnostic capacity using receiver operating curves: spherical component and eccentricity, maximum decentration, regular astigmatism in the center and in the periphery, mean astigmatism, irregularities, regular astigmatism in the center plus the irregularities, and total astigmatism. Logistic regression was performed to identify a combined diagnostic model. RESULTS: The study comprised 80 keratoconus eyes, 55 eyes diagnosed with subclinical keratoconus, and 50 normal eyes. Significant differences were detected in spherical eccentricity, maximum decentration, irregularities, regular astigmatism in the center and in the periphery, regular astigmatism in the center plus the irregularities, mean astigmatism, and total astigmatism parameters between the groups. Almost all parameters had high diagnostic ability in both study groups (area under the curve >90%). Among individual parameters, those with the highest predictive accuracy were the regular astigmatism in the center plus the irregularities (subclinical keratoconus 97.6%, keratoconus 98.8%) and the maximum decentration (subclinical keratoconus 91.4%, keratoconus 98.5%). Sufficient predictive accuracy (subclinical keratoconus 99.4, keratoconus 100%) was identified in a diagnostic model that combined the regular astigmatism in the center plus the irregularities and the maximum decentration. CONCLUSION: Fourier decomposition of keratometric data provided parameters with high accuracy in differentiating corneas with subclinical keratoconus from normal corneas and should be included to allow prompt diagnosis of keratoconus. (C) 2016 ASCRS and ESCRS
引用
收藏
页码:731 / 737
页数:7
相关论文
共 50 条
  • [1] Progression of keratoconus assessed by fourier analysis of videokeratography data
    Oshika, T
    Tanabe, T
    Tomidokoro, A
    Amano, S
    OPHTHALMOLOGY, 2002, 109 (02) : 339 - 342
  • [2] Fourier analysis algorithm for the posterior corneal keratometric data: clinical usefulness in keratoconus
    Sideroudi, Haris
    Labiris, Georgios
    Georgantzoglou, Kimon
    Ntonti, Panagiota
    Siganos, Charalambos
    Kozobolis, Vassilios
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2017, 37 (04) : 460 - 466
  • [3] Quantitative evaluation of irregular astigmatism by Fourier series harmonic analysis of videokeratography data
    Oshika, T
    Tomidokoro, A
    Maruo, K
    Tokunaga, T
    Miyata, N
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1998, 39 (05) : 705 - 709
  • [4] Corneal astigmatism after scleral buckling surgery assessed by Fourier analysis of videokeratography data
    Tomidokoro, A
    Oshika, T
    Kojima, T
    CORNEA, 1998, 17 (05) : 517 - 521
  • [5] Fourier analysis of corneal Scheimpflug imaging: clinical use in keratoconus
    Dorukcan Akincioglu
    Gokhan Ozge
    Onder Ayyildiz
    Gokcen Gokce
    Umut Karaca
    Fatih Mehmet Mutlu
    International Journal of Ophthalmology, 2021, 14 (12) : 1963 - 1969
  • [6] Fourier analysis of corneal Scheimpflug imaging: clinical use in keratoconus
    Akincioglu, Dorukcan
    Ozge, Gokhan
    Ayyildiz, Onder
    Gokce, Gokcen
    Karaca, Umut
    Mutlu, Fatih Mehmet
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (12) : 1963 - 1969
  • [7] Corneal regular and irregular astigmatism assessed by Fourier analysis of videokeratography data in normal and pathologic eyes
    Tanabe, T
    Tomidokoro, A
    Samejima, T
    Miyata, K
    Sato, M
    Kaji, Y
    Oshika, T
    OPHTHALMOLOGY, 2004, 111 (04) : 752 - 757
  • [8] Visual acuity measurements using Fourier series harmonic analysis of videokeratography data in eyes after penetrating keratoplasty
    Miyai, T
    Miyata, K
    Nejima, R
    Samejima, T
    Hiraoka, T
    Kiuchi, T
    Kaji, Y
    Oshika, T
    OPHTHALMOLOGY, 2005, 112 (03) : 420 - 424
  • [9] Usefulness Analysis of a Clinical Data Repository Design
    Ong, Daphne E.
    Frize, Monique
    Gilchrist, Jeff
    Bariciak, Erika
    Ennett, Colleen M.
    2013 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS PROCEEDINGS (MEMEA), 2013, : 86 - 90
  • [10] CLINICAL USEFULNESS OF VECTORCARDIOGRAPHY - IMPORTANCE OF THE METHOD OF DATA ANALYSIS
    WHIPPLE, GH
    LEVINE, HD
    CIRCULATION, 1957, 16 (05) : 951 - 951