Corneal regular and irregular astigmatism assessed by Fourier analysis of videokeratography data in normal and pathologic eyes

被引:49
|
作者
Tanabe, T
Tomidokoro, A
Samejima, T
Miyata, K
Sato, M
Kaji, Y
Oshika, T
机构
[1] Univ Tsukuba, Inst Clin Med, Dept Ophthalmol, Tsukuba, Ibaraki 3058575, Japan
[2] Univ Tokyo, Sch Med, Dept Ophthalmol, Tokyo, Japan
[3] Miyata Eye Hosp, Meiwakai Med Fdn, Miyazaki, Japan
[4] Univ Tsukuba, Inst Clin Med, Dept Ophthalmol, Tsukuba, Ibaraki, Japan
关键词
D O I
10.1016/j.ophtha.2003.06.019
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess corneal regular and irregular astigmatism using Fourier series harmonic analysis of videokeratography data in normal subjects, as well as in subjects with pathologic and postsurgical conditions. Study Design: Retrospective, case-control study. Participants: Two hundred normal eyes, 58 eyes with keratoconus, 24 eyes with suspect keratoconus, 100 eyes that underwent LASIK, 101 eyes that underwent photorefractive keratectomy (PRK), and 79 eyes that underwent penetrating keratoplasty (PK). Methods: Videokeratography data were decomposed, using Fourier analysis, into spherical power, regular astigmatism, asymmetry, and higher order irregularity. Results: The normal range of the Fourier indices was defined as the mean +/-2xstandard deviation in the normal eyes, which were 40.81-47.13 diopters (D) for spherical power, 0-1.04 D for regular astigmatism, 0.02-0.68 D for asymmetry, and 0.05-0.17 for higher order irregularity. The keratoconus and suspect keratoconus groups showed significantly greater values in all indices than did the normal group (P<0.001 or 0.0001, Mann-Whitney test with Bonferroni correction). Eyes that had undergone LASIK and PRK had significantly smaller spherical power and regular astigmatism (P<0.0001) and significantly larger asymmetry (P<0.0001) than the normal eyes. All indices were significantly greater in the PK group than in the normal group (P<0.0001). Among the eyes tested in this study, eyes with keratoconus had the largest asymmetry, whereas eyes that had undergone PK had the most irregular corneas. Conclusions: The normal range was defined for the corneal irregular astigmatism index (asymmetry and higher order irregularity) to support future studies in this field. Eyes with ocular pathologic and postsurgical conditions were evaluated using the normal range. (C) 2004 by the American Academy of Ophthalmology.
引用
收藏
页码:752 / 757
页数:6
相关论文
共 50 条
  • [1] Corneal astigmatism after scleral buckling surgery assessed by Fourier analysis of videokeratography data
    Tomidokoro, A
    Oshika, T
    Kojima, T
    [J]. CORNEA, 1998, 17 (05) : 517 - 521
  • [2] Quantitative evaluation of irregular astigmatism by Fourier series harmonic analysis of videokeratography data
    Oshika, T
    Tomidokoro, A
    Maruo, K
    Tokunaga, T
    Miyata, N
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1998, 39 (05) : 705 - 709
  • [3] Effect of Pterygium Surgery on Corneal Regular and Irregular Astigmatism: Evaluation with Fourier Analysis
    Adiguzel, Ufuk
    Yesilli, Munevver
    Sari, Ayca
    Kervanci, Tulin
    Oz, Ozay
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2008, 38 (01): : 4 - 8
  • [4] Fourier Analysis on Regular and Irregular Astigmatism of Anterior and Posterior Corneal Surfaces in Fuchs Endothelial Corneal Dystrophy
    Oie, Yoshinori
    Yasukura, Yuichi
    Nishida, Nozomi
    Koh, Shizuka
    Kawasaki, Ryo
    Maeda, Naoyuki
    Jhanji, Vishal
    Nishida, Kohji
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 223 : 33 - 41
  • [5] Comparison of corneal irregular astigmatism by the type of corneal regular astigmatism
    Yuta Ueno
    Risa Nomura
    Takahiro Hiraoka
    Katsuhito Kinoshita
    Mutsuko Ohara
    Tetsuro Oshika
    [J]. Scientific Reports, 11
  • [6] Comparison of corneal irregular astigmatism by the type of corneal regular astigmatism
    Ueno, Yuta
    Nomura, Risa
    Hiraoka, Takahiro
    Kinoshita, Katsuhito
    Ohara, Mutsuko
    Oshika, Tetsuro
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [7] Progression of keratoconus assessed by fourier analysis of videokeratography data
    Oshika, T
    Tanabe, T
    Tomidokoro, A
    Amano, S
    [J]. OPHTHALMOLOGY, 2002, 109 (02) : 339 - 342
  • [8] The association between central and peripheral corneal astigmatism based on Fourier analysis in normal eyes
    Maseedupally, Vinod
    Ho, Kerry
    Tran, Kevin
    Swarbrick, Helen A.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [9] Fourier Analysis of Corneal Irregular Astigmatism Due to the Anterior Corneal Surface in Dry Eye
    Koh, Shizuka
    Maeda, Naoyuki
    Ogawa, Mai
    Asonuma, Sanae
    Takai, Yoshihiro
    Maruyama, Kazuichi
    Klyce, Stephen D.
    Nishida, Kohji
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2019, 45 (03): : 188 - 194
  • [10] Repeatability and Agreement of 4 Biometers Measuring Corneal Astigmatism in Eyes With Irregular Corneal Astigmatism Component
    Wang, Lan
    Shao, Xu
    Fu, Jin-Ling
    Hu, Jing-Jing
    Zhou, Kai-Jing
    Li, Ran
    Yu, A-Yong
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 265 : 200 - 212