Assessment of matrix effects associated with Fe isotope analysis using 266 nm femtosecond and 193 nm nanosecond laser ablation multi-collector inductively coupled plasma mass spectrometry

被引:48
|
作者
Zheng, Xin-Yuan [1 ,2 ]
Beard, Brian L. [1 ,2 ]
Johnson, Clark M. [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Geosci, 1215 W Dayton St, Madison, WI 53706 USA
[2] NASA, Astrobiol Inst, Washington, DC 20546 USA
关键词
MC-ICP-MS; LANGMUIR PROBE MEASUREMENTS; HIGH-PRECISION FE; IN-SITU; ELECTRON-DENSITY; SPACE-CHARGE; NONTRADITIONAL ISOTOPES; ELEMENTAL FRACTIONATION; ANALYTICAL-CHEMISTRY; IRON-METEORITES;
D O I
10.1039/c7ja00272f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study evaluated matrix effects during Fe isotope analysis using a 266 nm femtosecond (fs) laser and a 193 nm nanosecond (ns) laser coupled to a multi-collector ICP-MS. During 150 second spot analysis on pyrite, Fe isotope fractionation was not observed for fs-laser ablation (fs-LA), but was evident for ns-LA. The observed downhole Fe isotope fractionation during ns-LA is caused by multiple processes comprising ablation, transport, and ionization in the ICP. Contrary to the common perception of "matrix-free" analysis, matrix effects clearly exist during fs-LA analysis; small deviations of up to similar to 0.2 parts per thousand in the measured Fe-56/Fe-54 ratios from the true value of magnetite grains with >=similar to 8 wt% impurities were resolved using a nearly pure magnetite as the bracketing standard. Moreover, inaccurate and imprecise Fe-56/Fe-54 results were obtained when magnetite and pyrrhotite was measured against a non-matrix-matchedl standard (pyrite or Fe metal). The observed matrix effects during fs-LA cannot be explained by formation of a large heat-affected zone during ablation, but result from the influence of different chemical compositions of samples and standards on space-charge effects in the ICP-MS. Such matrix effects can be largely suppressed by water addition during analysis at a price of reduced sensitivity, so that precise and accurate Fe isotope analysis to a similar to 0.1 parts per thousand level can be routinely achieved under "wet" conditions without matrix-matching between sample and standard. These results may reconcile dramatically different precisions previously reported for Fe isotope analysis by fs-lasers, and also highlight fs-LA-MC-ICP-MS as an appealing option for in situ Fe isotope analysis on samples with complex matrices and high-symmetry minerals, both of which encounter significant analytical difficulties using secondary ion mass spectrometry (SIMS). For ns-LA, in addition to similar composition-related matrix effects experienced by fs-LA in the ICP, matrix effects also originate from ablation-related processes that produce sample particles with matrix-dependent size distributions and, often, larger aerodynamic sizes, resulting in highly inaccurate Fe-56/Fe-54 results during non-matrix-matched analysis under "dry" conditions. The collective matrix effects during Fe isotope analysis by ns-LA cannot be fully suppressed by water addition, therefore, matrix matching is required for accurate Fe isotope analysis by ns-LA.
引用
收藏
页码:68 / 83
页数:16
相关论文
共 50 条
  • [41] Capabilities of an Argon Fluoride 193 nm excimer laser for laser ablation inductively coupled plasma mass spectrometry microanalysis of geological materials
    Swiss Federal Inst of Technology, Zurich, Zurich, Switzerland
    J Anal At Spectrom, 9 (939-944):
  • [42] Characterization of Four Copper Materials for Application as Reference Materials for High Precision Copper Isotope Analysis by Laser Ablation Inductively Coupled Plasma Multi-Collector Mass Spectrometry
    Yang, Zhaoping
    Jackson, Simon Edward
    Skulski, Thomas
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [43] Analysis of In situ Pb Isotope in Sulfides by Laser Ablation Multiple Collector Inductively Coupled Plasma Mass Spectrometry
    Zhang Wen
    Hu Zhao-Chu
    Jin Zhen-Min
    Liu Yong-Sheng
    Ling Wen-Li
    Hu Qing-Hai
    Fu Jia-Li
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (01) : 14 - 22
  • [44] Optimization of ablation protocol for 200 nm UV femtosecond laser in precise U-Pb age dating coupled to multi-collector ICP mass spectrometry
    Kimura, Jun-Ichi
    Chang, Qing
    Tani, Kenichiro
    GEOCHEMICAL JOURNAL, 2011, 45 (04) : 283 - 296
  • [45] Matrix-independent boron isotope analysis of silicate and carbonate reference materials by ultraviolet femtosecond laser ablation multi-collector inductively coupled plasma mass spectrometry with application to the cold-water coral Desmophyllum dianthus
    Steinhoefel, Grit
    Beck, Kristina K. K.
    Benthien, Albert
    Richter, Klaus-Uwe
    Schmidt-Grieb, Gertraud M. M.
    Bijma, Jelle
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2023, 37 (13) : e9508
  • [46] Trace element analysis of synthetic mono- and poly-crystalline CaF2 by ultraviolet laser ablation inductively coupled plasma mass spectrometry at 266 and 193 nm
    Koch, J
    Feldmann, I
    Hattendorf, B
    Günther, D
    Engel, U
    Jakubowski, N
    Bolshov, M
    Niemax, K
    Hergenröder, R
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (06) : 1057 - 1070
  • [47] A re-assessment of nickel-doping method in iron isotope analysis on rock samples using multi-collector inductively coupled plasma mass spectrometry
    Gong, Hongmei
    Guo, Pengyuan
    Chen, Shuo
    Duan, Meng
    Sun, Pu
    Wang, Xiaohong
    Niu, Yaoling
    ACTA GEOCHIMICA, 2020, 39 (3) : 355 - 364
  • [48] A re-assessment of nickel-doping method in iron isotope analysis on rock samples using multi-collector inductively coupled plasma mass spectrometry
    Hongmei Gong
    Pengyuan Guo
    Shuo Chen
    Meng Duan
    Pu Sun
    Xiaohong Wang
    Yaoling Niu
    Acta Geochimica, 2020, 39 (03) : 355 - 364
  • [49] A re-assessment of nickel-doping method in iron isotope analysis on rock samples using multi-collector inductively coupled plasma mass spectrometry
    Hongmei Gong
    Pengyuan Guo
    Shuo Chen
    Meng Duan
    Pu Sun
    Xiaohong Wang
    Yaoling Niu
    Acta Geochimica, 2020, 39 : 355 - 364
  • [50] Comparison of ultraviolet femtosecond and nanosecond laser ablation inductively coupled plasma mass spectrometry analysis in glass, monazite, and zircon
    Poitrasson, F
    Mao, XL
    Mao, SS
    Freydier, R
    Russo, RE
    ANALYTICAL CHEMISTRY, 2003, 75 (22) : 6184 - 6190