Reliability assessment of passive containment isolation system using APSRA methodology

被引:10
|
作者
Nayak, A. K. [1 ]
Jain, Vikas [1 ]
Gartia, M. R. [1 ]
Srivastava, A. [2 ]
Prasad, Hari [2 ]
Anthony, A. [1 ]
Gaikwad, A. J. [2 ]
Bhatia, S. [1 ]
Sinha, R. K. [1 ]
机构
[1] Bhabha Atom Res Ctr, Reactor Design Dev Grp, Bombay 400085, Maharashtra, India
[2] Bhabha Atom Res Ctr, Reactor Safety Div, Bombay 400085, Maharashtra, India
关键词
D O I
10.1016/j.anucene.2008.08.011
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this paper, a methodology known as APSRA (Assessment of Passive System ReliAbility) has been employed for evaluation of the reliability of passive systems. The methodology has been applied to the passive containment isolation system (PCIS) of the Indian advanced heavy water reactor (AHWR). In the APSRA methodology, the passive system reliability evaluation is based on the failure probability of the system to carryout the desired function. The methodology first determines the operational characteristics of the system and the failure conditions by assigning a predetermined failure criterion. The failure surface is predicted using a best estimate code considering deviations of the operating parameters from their nominal states, which affect the PCIS performance. APSRA proposes to compare the code predictions with the test data to generate the uncertainties on the failure parameter prediction, which is later considered in the code for accurate prediction of failure surface of the system. Once the failure surface of the system is predicted, the cause of failure is examined through root diagnosis, which occurs mainly due to failure of mechanical components. The failure probability of these components is evaluated through a classical PSA treatment using the generic data. The reliability of the PCIS is evaluated from the probability of availability of the components for the success of the passive containment isolation system. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2270 / 2279
页数:10
相关论文
共 50 条
  • [31] THE PASSIVE CONTAINMENT SYSTEM - AN INHERENTLY SAFE REACTOR SYSTEM
    FALLS, OB
    KLEIMOLA, FW
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1984, 47 : 302 - 304
  • [32] Methodology for Assessment of the Impact of Smart Transformers on Power System Reliability
    Chen, Junru
    Nouri, Alireza
    Keane, Andrew
    O'Donnell, Terence
    45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 6701 - 6706
  • [33] Design Methodology of a Passive Vibration Isolation System for an Optical System With Sensitive Line-of-Sight
    Keqi Qi
    Lei Dai
    Shaoxin Wang
    Yongming Yang
    Yalin Ding
    Chao Fang
    Chao Lin
    Photonic Sensors, 2021, 11 : 435 - 447
  • [34] Design Methodology of a Passive Vibration Isolation System for an Optical System With Sensitive Line-of-Sight
    Qi, Keqi
    Dai, Lei
    Wang, Shaoxin
    Yang, Yongming
    Ding, Yalin
    Fang, Chao
    Lin, Chao
    PHOTONIC SENSORS, 2021, 11 (04) : 435 - 447
  • [35] Analysis of a passive containment cooling system for NPPs
    Huang, Zheng
    Hedongli Gongcheng/Nuclear Power Engineering, 2014, 35 (06): : 31 - 36
  • [36] Research on Containment Passive Heat Sink System
    Sheng M.
    Zhang X.
    Liang X.
    Qiu J.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2023, 57 (10): : 1928 - 1937
  • [37] The modeling of passive containment cooling system and sensitivity analysis using the SPRUCE code
    Zhang Z.
    Zhao Z.
    Yang F.
    Guo C.
    Chen P.
    International Journal of Advanced Nuclear Reactor Design and Technology, 2023, 5 (02): : 72 - 76
  • [38] Water Distribution Network Reliability Assessment and Isolation Valve System
    Giustolisi, Orazio
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2020, 146 (01)
  • [39] RELIABILITY ASSESSMENT OF REACTOR AP1000 PASSIVE ERVC SYSTEM
    Cui Chengxin
    Huang Ting
    Chen Lian
    Chen Ying
    Zhang Lei
    PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 4, 2017,
  • [40] Reliability of Passive Physical Activity Assessment for Inpatients Using Marker-Free Motion Tracking System
    Biao Yang
    Kewei Duan
    Wanxia Yao
    JournalofHarbinInstituteofTechnology(NewSeries), 2021, 28 (02) : 21 - 27