Small-volume fiber-optic evanescent-wave absorption sensor for nitrite determination

被引:35
|
作者
Xiong, Yan [1 ]
Zhu, Dao-qian [1 ]
Duan, Chun-feng [1 ]
Wang, Jian-wei [1 ]
Guan, Ya-feng [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Dept Instrumentat & Analyt Chem, Dalian 116023, Peoples R China
关键词
Fiber-optic sensor; Nitrite determination; Evanescent wave; Small volume; WATER SAMPLES; NITRATE; SYSTEM; IONS; TRACES;
D O I
10.1007/s00216-009-3246-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel small-volume fiber-optic evanescent-wave absorption sensor based on the Griess-Ilosvay reaction has been developed and evaluated for nitrite determination. The sensor was constructed by inserting a decladded optical fiber into a transparent capillary to form an annular column microchannel. The Evanescent wave (EW) field produced on the optical fiber core surface penetrated into the surrounding medium and interacted with the azo dye, which was generated by the reaction of nitrite and nitrite-sensitive reagents. The detector was designed to be parallel to the axis of the optical fiber. The defined absorbance was linear with the concentration of nitrite in the range from 0.05 to 10 mg L-1, and the detection limit was 0.02 mg L-1 (3 sigma) with the relative standard deviation (RSD) of 2.6% (n=8). The present sensor was successfully used to determine nitrite in real samples of mineral water, tap water, rain water, and seawater. The results were consistent with the data obtained by standard spectrophotometric method, showing potential of the proposed sensor for practical application.
引用
收藏
页码:943 / 948
页数:6
相关论文
共 50 条
  • [11] Optical sensor for fluoride determination in tea sample based on evanescent-wave interaction and fiber-optic integration
    Xiong, Yan
    Wu, Jiayi
    Wang, Qing
    Xu, Jing
    Fang, Shenwen
    Chen, Jie
    Duan, Ming
    TALANTA, 2017, 174 : 372 - 379
  • [12] Evanescent-wave spectroscopic fiber optic pH sensor
    Egami, C
    Takeda, K
    Isai, M
    Ogita, M
    OPTICS COMMUNICATIONS, 1996, 122 (4-6) : 122 - 126
  • [13] A fiber-optic evanescent-wave hydrogen gas sensor using palladium supported tungsten oxide
    Sekimoto, S
    Okazaki, S
    Nakagawa, H
    Fukuda, K
    Asakura, S
    Sigemori, T
    Takahasi, S
    TECHNICAL DIGEST OF THE SEVENTH INTERNATIONAL MEETING ON CHEMICAL SENSORS, 1998, : 365 - 367
  • [14] Investigation of fiber-optic evanescent-wave sensors for detection of liquid hydrocarbons
    Tobiska, Petr
    Chomat, Miroslav
    Matejec, Vlastimil
    Berkova, Daniela
    Huttel, Ivan
    Sensors and Actuators, B: Chemical, 1998, B51 (1-3): : 152 - 158
  • [15] Investigation of fiber-optic evanescent-wave sensors for detection of liquid hydrocarbons
    Tobiska, P
    Chomát, M
    Matejec, V
    Berková, D
    Hüttel, I
    SENSORS AND ACTUATORS B-CHEMICAL, 1998, 51 (1-3) : 152 - 158
  • [16] Fiber-optic evanescent-wave absorption copper(II) sensor based on sol-gel-derived organofunctionalized silica cladding
    Yeh, TC
    Tien, P
    Chau, LK
    APPLIED SPECTROSCOPY, 2001, 55 (10) : 1320 - 1326
  • [17] Numerical evaluation of fiber-optic evanescent wave sensor
    Ruan, H
    Chen, YS
    Chen, SW
    Xue, MQ
    FIBER OPTIC SENSORS V, 1996, 2895 : 346 - 349
  • [18] Fiber-optic evanescent wave sensor with a segmented structure
    Lou, Jun
    Xu, Hong-zhi
    Xu, Ben
    Huang, Jie
    Li, Ben-chong
    Shen, Wei-min
    APPLIED OPTICS, 2014, 53 (19) : 4200 - 4205
  • [19] Launching the excitation light to a taper externally: Comprehensive performance improvement of fiber-optic evanescent-wave sensor
    Chen, Huacai
    Ma, Jianjun
    Bock, Wojtek J.
    21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753
  • [20] A fiber-optic evanescent-wave hydrogen gas sensor using palladium-supported tungsten oxide
    Sekimoto, S
    Nakagawa, H
    Okazaki, S
    Fukuda, K
    Asakura, S
    Shigemori, T
    Takahashi, S
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 66 (1-3) : 142 - 145