Launching the excitation light to a taper externally: Comprehensive performance improvement of fiber-optic evanescent-wave sensor

被引:0
|
作者
Chen, Huacai [1 ]
Ma, Jianjun [2 ]
Bock, Wojtek J. [2 ]
机构
[1] China Jiliang Univ, Coll Opt & Elect Technol, Xueyuan St, Hangzhou 310018, Zhejiang, Peoples R China
[2] Univ Quebec, Ctr Rech photon, Dept Informat Engn, Hull, PQ J8X 3X7, Canada
来源
21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS | 2011年 / 7753卷
基金
加拿大自然科学与工程研究理事会;
关键词
Fiber-optic sensor; fiber taper; evanescent wave; signal collection efficiency; fluorescence; spectroscopy;
D O I
10.1117/12.884737
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A taper at one end of the fiber serving as the sensing element is widely used to enhance the performance of evanescent-wave (EW) fiber-optic sensors. However, almost all sensors of this type launch the excitation light into the core at the opposite end and the entire taper has to be immersed into the bulky sample volume. This paper introduces a new way of injecting excitation light: from the outside of the taper perpendicularly. As a result, several desirable features are achieved simultaneously, including a dramatic increase of collectable EW signal, elimination of stray excitation light, easy system construction and reduction of the sample volume to mere microliters.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Fiber-optic evanescent-wave sensor
    Rodríguez-Rodríguez, E
    Guadarrama, RB
    Torres, RQ
    Eighth International Symposium on Laser Metrology: MACRO-, MICRO-, AND NANO-TECHNOLOGIES APPLIED IN SCIENCE, ENGINEERING, AND INDUSTRY, 2005, 5776 : 443 - 447
  • [2] Model of a fiber-optic evanescent-wave fluorescence sensor
    Woerdeman, DL
    Parnas, RS
    APPLIED SPECTROSCOPY, 2001, 55 (03) : 331 - 337
  • [3] Experiments study on fiber-optic evanescent-wave hydrogen sensor
    Zhao, Yu
    Liu, Yongzhi
    Yan, Qifa
    Chen, Dejun
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2007, 28 (SUPPL. 2): : 366 - 369
  • [4] Determination of bacterial activity by use of an evanescent-wave fiber-optic sensor
    John, M. Shelly
    Kishen, Anil
    Sing, Lim Chu
    Asundi, Anand
    Applied Optics, 2002, 41 (34): : 7334 - 7338
  • [5] Determination of bacterial activity by use of an evanescent-wave fiber-optic sensor
    John, MS
    Kishen, A
    Sing, LC
    Asundi, A
    APPLIED OPTICS, 2002, 41 (34) : 7334 - 7338
  • [6] Theory of fiber-optic, evanescent-wave spectroscopy and sensors
    Messica, A
    Greenstein, A
    Katzir, A
    APPLIED OPTICS, 1996, 35 (13): : 2274 - 2284
  • [7] Fiber-optic evanescent-wave immunosensor for large molecules
    Shriver-Lake, Lisa C.
    Ogert, Robert A.
    Ligler, Frances S.
    Sensors and Actuators, B: Chemical, 1993, B11 (1-3) : 239 - 243
  • [8] Enhancing signal quality of evanescent-wave multimode fiber optic sensor using diffuse excitation light
    Ma, Jianjun
    Bock, Wojtek J.
    ICEPT: 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONICS PACKAGING TECHNOLOGY, PROCEEDINGS, 2007, : 508 - 512
  • [9] Evanescent-wave spectroscopic fiber optic pH sensor
    Egami, C
    Takeda, K
    Isai, M
    Ogita, M
    OPTICS COMMUNICATIONS, 1996, 122 (4-6) : 122 - 126
  • [10] Small-volume fiber-optic evanescent-wave absorption sensor for nitrite determination
    Yan Xiong
    Dao-qian Zhu
    Chun-feng Duan
    Jian-wei Wang
    Ya-feng Guan
    Analytical and Bioanalytical Chemistry, 2010, 396 : 943 - 948