Evaluation of Abbott RealTime CT/NG Assay for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Cervical Swabs from Female Sex Workers in China

被引:9
|
作者
Han, Yan
Yin, Yue-ping [1 ]
Shi, Mei-qin
Zheng, Bing-jie
Zhong, Ming-ying
Jiang, Ning
Chen, Shao-chun
Chen, Xiang-sheng
机构
[1] China Chinese CDC, Natl Ctr STD Control, Nanjing, Jiangsu, Peoples R China
来源
PLOS ONE | 2014年 / 9卷 / 03期
关键词
SEXUALLY-TRANSMITTED INFECTIONS; POPULATION-BASED SURVEY; PREVALENCE; DISEASES; VARIANT; SYSTEM; WOMEN;
D O I
10.1371/journal.pone.0089658
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: To evaluate the performance of the Abbott RealTime CT/NG assay for detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) among female sex workers (FSWs) in China. Methods: Cervical swabs from 997 participants were blindly detected by the Abbott RealTime CT/NG assay on the automated m2000 molecular platform and Roche Cobas Amplicor CT/NG assay. Discrepant analysis were confirmed by the Qiagen care CT PCR assay. The sample was defined as candidate nvCT-positive if it was CT positive in the Abbott m2000 assay, but CT negative in the other two assays. Results: 25 specimens that were discordant for CT and 26 specimens that were discordant for NG between the two assays were resolved by Qiagen care CT & NG PCR assays. The sensitivity and specificity, respectively, for Abbott m2000 assay were 92.59% and 100% for CT and 95.45% and 99.90% for NG. The positive predictive value (PPV) and negative predictive value (NPV) of Abbott m2000 assay were 100% and 98.52% for CT and 95.5% and 99.90% for NG, respectively. No candidate new-variant CT(nvCT) specimens were identified. Conclusion: Abbott RealTime CT/NG assay were more specify for CT and NG detection, however, its sensitivity for CT and NG were a little bit lower than Roche Cobas Amplicor CT/NG assay. Abbott RealTime CT/NG assay had higher PPV for NG detection than Roche Cobas Amplicor CT/NG assay; it would be more suitable for screening for population with low-prevalence NG. There is currently no evidence that nvCT is present in FSWs in China.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Comparison of the Abbott m2000 RealTime CT Assay and the Cepheid GeneXpert CT/NG Assay to the Roche Amplicor CT Assay for Detection of Chlamydia trachomatis in Ocular Samples from Tanzania
    Dize, Laura
    West, Sheila
    Williams, James A.
    Van der Pol, Barbara
    Quinn, Thomas C.
    Gaydos, Charlotte A.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (05) : 1611 - 1613
  • [42] Evaluation of a screening algorithm for the diagnosis of genital infections with Neisseria gonorrhoeae and Chlamydia trachomatis among female sex workers in Benin
    Germain, M
    Alary, M
    Guedeme, A
    Padonou, F
    Davo, N
    Adjovi, C
    vanDyck, E
    Joly, JR
    Mahony, JB
    SEXUALLY TRANSMITTED DISEASES, 1997, 24 (02) : 109 - 115
  • [43] Evaluation of the APTIMA Combo 2 assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.
    Boyadzhyan, B
    Yashina, T
    Yatabe, JAH
    Patnaik, M
    CLINICAL CHEMISTRY, 2001, 47 (11) : 2082 - 2082
  • [44] Performance of the Cepheid CT/NG Xpert Rapid PCR Test for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Gaydos, Charlotte A.
    Van der Pol, Barbara
    Jett-Goheen, Mary
    Barnes, Mathilda
    Quinn, Nicole
    Clark, Carey
    Daniel, Grace E.
    Dixon, Paula B.
    Hook, Edward W., III
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (06) : 1666 - 1672
  • [45] Evaluation of the Siemens VERSANT® CT/GC DNA 1.0 Assay (kPCR) for detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Bongaerts, Maarten
    van de Bovenkamp, Jeroen H. B.
    Morre, Servaas A.
    Manders, Monique E. L. M.
    Heddema, Edou R.
    JOURNAL OF MICROBIOLOGICAL METHODS, 2011, 87 (02) : 139 - 142
  • [46] High prevalence of Chlamydia trachomatis, Neisseria gonorrhoeae and Mycoplasma genitalium in female commercial sex workers in Japan
    Tsunoe, H
    Tanaka, M
    Nakayama, H
    Sano, M
    Nakamura, G
    Shin, T
    Kanayama, A
    Kobayashi, I
    Mochida, O
    Kumazawa, J
    Naito, S
    INTERNATIONAL JOURNAL OF STD & AIDS, 2000, 11 (12) : 790 - 794
  • [47] Molecular detection and confirmation of Neisseria gonorrhoeae in urogenital and extragenital specimens using the Abbott CT/NG RealTime assay and an in-house assay targeting the porA pseudogene
    Walsh, A.
    Rourke, F. O.
    Crowley, B.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2011, 30 (04) : 561 - 567
  • [48] Molecular detection and confirmation of Neisseria gonorrhoeae in urogenital and extragenital specimens using the Abbott CT/NG RealTime assay and an in-house assay targeting the porA pseudogene
    A. Walsh
    F. O. Rourke
    B. Crowley
    European Journal of Clinical Microbiology & Infectious Diseases, 2011, 30 : 561 - 567
  • [49] Novel cost-effective quality control approach for the Cepheid Xpert CT/NG assay for the detection of Chlamydia Trachomatis and Neisseria Gonorrhoeae
    Chan, Maurice
    Jiang, Boran
    Ng, Siew Yong Lily
    Tan, Thean Yen
    JOURNAL OF MICROBIOLOGICAL METHODS, 2016, 125 : 87 - 90
  • [50] Despite Excellent Test Characteristics of the cobas 4800 CT/NG Assay, Detection of Oropharyngeal Chlamydia trachomatis and Neisseria gonorrhoeae Remains Challenging
    van Niekerk, J. M.
    van der Veer, B. M. J. W.
    Hoebe, C. J. P. A.
    van de Bovenkamp, J.
    van Herk, C.
    van Loo, I. H. M.
    van Alphen, L. B.
    Wolffs, P. F. G.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (02)