On-line focused microwave digestion hydride generation of inorganic and organic selenium: Total determination and inorganic selenium speciation by atomic absorption spectrometry

被引:0
|
作者
LaFuente, JMG [1 ]
Sanchez, MLF [1 ]
MarchanteGayon, JM [1 ]
Uria, JES [1 ]
SanzMedel, A [1 ]
机构
[1] UNIV OVIEDO,DEPT PHYS & ANALYT CHEM,E-33006 OVIEDO,SPAIN
关键词
total selenium determination; selenium speciation; on-line focused microwave digestion; hydride generation; atomic absorption spectrometry;
D O I
10.1016/S0584-8547(96)01538-8
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
An on-line FIA pretreatment with HBr/KBrO3, assisted by on-line focused microwave-induced digestion, has been coupled with hydride generation-atomic absorption spectrometry (HG-AAS) for final detection for total selenium determination. This total selenium determination is virtually independent of the different Se species investigated (selenite, selenate, selenomethionine, selenoethionine and selenocystine). Detection limits of 0.8 mu g l(-1) of Se can be achieved by AAS with precisions better than 5%. This continuous flow system for selenium determination allows a high sample throughput (about 30 samples h(-1) can be analyzed) in which high automation can be achieved and constitutes a convenient real-time continuous detector for the different selenocompounds tested. Direct non-chromatographic speciation of inorganic selenium (selenite and selenate in their mixtures) is demonstrated by simple on-off operation of the focused microwaves connected in the flow system. Validation of this simple on-line FIA system has been carried out by analyzing total Se recovered from spiked tap waters and by speciating mixtures of Se(IV) and Se(VI) spiked to the same samples. The fast conversion of Se compounds into volatile selenium could be considered as a sort of specific ''general'' detector for Se compounds which can be extremely useful for Se speciation by hybrid chromatographic techniques.
引用
收藏
页码:1849 / 1857
页数:9
相关论文
共 50 条
  • [41] Feasibility study of ion-chromatography microwave assisted on-line species conversion hydride generation atomic absorption spectrometry for selenium speciation analysis of biological material
    Johansson, M
    Bordin, G
    Rodriguez, AR
    ANALYST, 2000, 125 (02) : 273 - 279
  • [42] On-line organoselenium interference removal for inorganic selenium species by flow injection coprecipitation preconcentration coupled with hydride generation atomic fluorescence spectrometry
    Wu, Hong
    Jin, Yan
    Shi, Yanqing
    Bi, Shuping
    TALANTA, 2007, 71 (04) : 1762 - 1768
  • [43] DETERMINATION OF TRACES OF ARSENIC AND SELENIUM BY HYDRIDE GENERATION-ATOMIC ABSORPTION SPECTROMETRY
    NARASAKI, H
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 321 (05): : 464 - 466
  • [44] Determination of Trace Selenium in Urine by Derivative Hydride Generation Atomic Absorption Spectrometry
    Han Wen Sun
    Jing Ha
    De Qiang Zhang
    Li Li Yang
    Jian Min Sun
    Analytical Sciences, 2002, 18 : 603 - 605
  • [45] DETERMINATION OF SELENIUM IN FORAGE SAMPLES BY HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY
    SCHNITGER, H
    LIECK, G
    LANDWIRTSCHAFTLICHE FORSCHUNG, 1981, 34 (1-2): : 1 - 7
  • [46] Determination of trace selenium in urine by derivative hydride generation atomic absorption spectrometry
    Sun, HW
    Ha, J
    Zhang, DQ
    Yang, LL
    Sun, JM
    ANALYTICAL SCIENCES, 2002, 18 (05) : 603 - 605
  • [47] Determination of arsenic(III) and total inorganic arsenic in water samples using an on-line sequential insertion system and hydride generation atomic absorption spectrometry
    Anthemidis, AN
    Zachariadis, GA
    Stratis, JA
    ANALYTICA CHIMICA ACTA, 2005, 547 (02) : 237 - 242
  • [48] Determination of As(III) and total inorganic As in water samples using an on-line solid phase extraction and flow injection hydride generation atomic absorption spectrometry
    Sigrist, Mirna
    Albertengo, Antonela
    Beldomenico, Horacio
    Tudino, Mabel
    JOURNAL OF HAZARDOUS MATERIALS, 2011, 188 (1-3) : 311 - 318
  • [49] DETERMINATION OF SELENIUM IN FISH FLESH BY HYDRIDE GENERATION ATOMIC-ABSORPTION SPECTROMETRY
    HANSSON, L
    PETTERSSON, J
    OLIN, A
    ANALYST, 1989, 114 (04) : 527 - 528
  • [50] Determination of trace arsenic and selenium in jellyfish by microwave digestion-hydride generation-atomic fluorescence spectrometry
    Liu, XG
    Yu, HH
    Zhao, ZQ
    Li, ZE
    Xu, ZH
    Li, PC
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (06) : 964 - 967