Feasibility study of ion-chromatography microwave assisted on-line species conversion hydride generation atomic absorption spectrometry for selenium speciation analysis of biological material
被引:27
|
作者:
Johansson, M
论文数: 0引用数: 0
h-index: 0
机构:
Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, BelgiumCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
Johansson, M
[1
]
Bordin, G
论文数: 0引用数: 0
h-index: 0
机构:
Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, BelgiumCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
Bordin, G
[1
]
Rodriguez, AR
论文数: 0引用数: 0
h-index: 0
机构:
Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, BelgiumCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
Rodriguez, AR
[1
]
机构:
[1] Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
A method for selenium speciation based on ion-chromatography (IC) microwave (MW) assisted on-line species conversion hydride generation (HG) atomic absorption spectrometry (AAS) is described. The conversion of selenium species into selenite was achieved by using hydrobromic acid and bromate. A potential interferent originating from the reagents was identified. Multivariate optimization of the IC-MW-HGAAS system was undertaken and the results show that the HBr/BrO3- ratio is a very important parameter, which should be carefully controlled both to obtain a high conversion efficiency and to diminish the interferent. The feasibility of the IC-MW-HGAAS system for real samples is demonstrated by the application of selenium speciation in extracts of the certified reference material CRM 402. The system is shown to be sensitive to interferences but the detection capability is good, relative detection limits being 1.0-1.6 ng g(-1) (based on a 50 mu L injection volume) for the species investigated: selenomethionine, selenite, selenate and selenocystine. Selenate was quantified in the CRM 402 extract at a level of approximate to 1.5 mu g g(-1) corresponding to approximate to 22% of the total selenium content in the material. The method described is concluded to be operationally defined because of the extraction procedure used.
机构:
Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, BelgiumCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
Johansson, M
Bordin, G
论文数: 0引用数: 0
h-index: 0
机构:
Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, BelgiumCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
Bordin, G
Rodriguez, AR
论文数: 0引用数: 0
h-index: 0
机构:
Commiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, BelgiumCommiss European Communities, Joint Res Ctr, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
Rodriguez, AR
TRACE ELEMENTS IN MAN AND ANIMALS 10,
2000,
: 169
-
172
机构:Nankai Univ, State Key Lab Funct Polymer Mat Adsorpt & Separat, Tianjin 300071, Peoples R China
Lu, CY
Yan, XP
论文数: 0引用数: 0
h-index: 0
机构:
Nankai Univ, State Key Lab Funct Polymer Mat Adsorpt & Separat, Tianjin 300071, Peoples R ChinaNankai Univ, State Key Lab Funct Polymer Mat Adsorpt & Separat, Tianjin 300071, Peoples R China