Composite slice-selective adiabatic excitation for prostate MRSI

被引:9
|
作者
de Castro, C. S. Arteaga [1 ]
Luttje, M. P. [1 ]
van Vulpen, M. [1 ]
Luijten, P. R. [1 ]
van der Heide, U. A. [1 ]
Klomp, D. W. J. [1 ]
机构
[1] Univ Med Ctr, Imaging Div, NL-3584 CX Utrecht, Netherlands
关键词
composite; adiabatic; MRSI; prostate; 7T; CONTRAST-ENHANCED MRI; CANCER; PULSES; TISSUE; POWER; 3-T;
D O I
10.1002/nbm.2881
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Higher magnetic field strengths, such as 7T, offer increased spectral resolution and higher signal-to-noise ratio. These properties can be very advantageous for MRSI. In particular, signals that generally overlap at lower fields, such as choline, polyamines and creatine, can be resolved at 7T. However, higher magnetic field strengths suffer from strong radiofrequency (RF) field nonuniformities. These nonuniformities become even stronger when using surface transceivers, such as an endorectal coil for prostate imaging. In order to obtain uniform excitations for accurate MRSI measurements, adiabatic sequences are therefore recommended. Conventional adiabatic MRS sequences (i.e. localization by adiabatic selective refocusing, LASER) have relatively long TEs, especially when optimized to measure the strongly coupled spins of citrate in the prostate. The semi-LASER (sLASER) sequence has a significantly shorter TE, although it does not provide adiabatic excitation. Therefore, we propose an adiabatic sLASER sequence that either has a composite adiabatic slice-selective excitation (cLASER) or a non-slice-selective adiabatic excitation (nsLASER), allowing for shorter TEs, whilst maintaining the adiabatic spin excitation. Furthermore, the spatial properties of the composite adiabatic excitation allow for a high slice excitation bandwidth, resulting in negligible chemical shift displacement artifacts. Exclusion of the slice selection can be considered once the field of view extends beyond the transmit field of the RF coil. The use of a transceiver at high magnetic field strengths has shown that the cLASER and nsLASER sequences are suitable for MRSI of the prostate in both phantom and in vivo validations. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:436 / 442
页数:7
相关论文
共 50 条
  • [1] Improved Slice-Selective Adiabatic Excitation
    Balchandani, Priti
    Glover, Gary
    Pauly, John
    Spielman, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 75 - 82
  • [2] Adiabatic Slice-Selective Excitation for Surface Coils
    Magnetic Resonance Center, Dept. Molec. Biophys. and Biochem., Yale University School of Medicine, New Haven, CT 06510, United States
    不详
    J. Magn. Reson., 1 (72-79):
  • [3] Adiabatic slice-selective excitation for surface coils
    Shen, J
    Rothman, DL
    JOURNAL OF MAGNETIC RESONANCE, 1997, 124 (01) : 72 - 79
  • [4] Velocity sensitivity of slice-selective excitation
    Lewis, DP
    Tsui, BMW
    Moran, PR
    MAGNETIC RESONANCE IMAGING, 1998, 16 (08) : 907 - 916
  • [5] Slice-selective excitation with B1+-insensitive composite pulses
    Moore, Jay
    Jankiewicz, Marcin
    Anderson, Adam W.
    Gore, John C.
    JOURNAL OF MAGNETIC RESONANCE, 2012, 214 : 200 - 211
  • [6] Towards 1H-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulses
    Tom W. J. Scheenen
    Arend Heerschap
    Dennis W. J. Klomp
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2008, 21
  • [7] Towards 1H-MRSI of the human brain at 7T with slice-selective adiabatic refocusing pulses
    Scheenen, Tom W. J.
    Heerschap, Arend
    Klomp, Dennis W. J.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2008, 21 (1-2) : 95 - 101
  • [8] Slice-selective tunable-flip adiabatic low peak-power excitation pulse
    Balchandani, Priti
    Pauly, John
    Spielman, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) : 1072 - 1078
  • [9] ADIABATIC SLICE-SELECTIVE RF PULSES AND A SINGLE-SHOT ADIABATIC LOCALIZATION PULSE SEQUENCE
    SLOTBOOM, J
    BOVEE, WMMJ
    CONCEPTS IN MAGNETIC RESONANCE, 1995, 7 (03): : 193 - 217
  • [10] Sparsity-enforced slice-selective MRI RF excitation pulse design
    Zelinski, Adam C.
    Wald, Lawrence L.
    Setsompop, Kawin
    Goyal, Vivek K.
    Adalsteinsson, Elfar
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (09) : 1213 - 1229