Composite slice-selective adiabatic excitation for prostate MRSI

被引:9
|
作者
de Castro, C. S. Arteaga [1 ]
Luttje, M. P. [1 ]
van Vulpen, M. [1 ]
Luijten, P. R. [1 ]
van der Heide, U. A. [1 ]
Klomp, D. W. J. [1 ]
机构
[1] Univ Med Ctr, Imaging Div, NL-3584 CX Utrecht, Netherlands
关键词
composite; adiabatic; MRSI; prostate; 7T; CONTRAST-ENHANCED MRI; CANCER; PULSES; TISSUE; POWER; 3-T;
D O I
10.1002/nbm.2881
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Higher magnetic field strengths, such as 7T, offer increased spectral resolution and higher signal-to-noise ratio. These properties can be very advantageous for MRSI. In particular, signals that generally overlap at lower fields, such as choline, polyamines and creatine, can be resolved at 7T. However, higher magnetic field strengths suffer from strong radiofrequency (RF) field nonuniformities. These nonuniformities become even stronger when using surface transceivers, such as an endorectal coil for prostate imaging. In order to obtain uniform excitations for accurate MRSI measurements, adiabatic sequences are therefore recommended. Conventional adiabatic MRS sequences (i.e. localization by adiabatic selective refocusing, LASER) have relatively long TEs, especially when optimized to measure the strongly coupled spins of citrate in the prostate. The semi-LASER (sLASER) sequence has a significantly shorter TE, although it does not provide adiabatic excitation. Therefore, we propose an adiabatic sLASER sequence that either has a composite adiabatic slice-selective excitation (cLASER) or a non-slice-selective adiabatic excitation (nsLASER), allowing for shorter TEs, whilst maintaining the adiabatic spin excitation. Furthermore, the spatial properties of the composite adiabatic excitation allow for a high slice excitation bandwidth, resulting in negligible chemical shift displacement artifacts. Exclusion of the slice selection can be considered once the field of view extends beyond the transmit field of the RF coil. The use of a transceiver at high magnetic field strengths has shown that the cLASER and nsLASER sequences are suitable for MRSI of the prostate in both phantom and in vivo validations. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:436 / 442
页数:7
相关论文
共 50 条
  • [21] Ultrafast multi-slice spatiotemporally encoded MRI with slice-selective dimension segmented
    Zhang, Ting
    Chen, Lin
    Huang, Jianpan
    Li, Jing
    Cai, Shuhui
    Cai, Congbo
    Chen, Zhong
    JOURNAL OF MAGNETIC RESONANCE, 2016, 269 : 138 - 145
  • [22] A loop resonator for slice-selective in vivo EPR imaging in rats
    Hirata, Hiroshi
    He, Guanglong
    Deng, Yuanmu
    Salikhov, Ildar
    Petryakov, Sergey
    Zweier, Jay L.
    JOURNAL OF MAGNETIC RESONANCE, 2008, 190 (01) : 124 - 134
  • [23] Fast cardiac T1ρ,adiab mapping using slice-selective adiabatic spin-lock preparation pulses
    Tyler, Andrew
    Kunze, Karl
    Neji, Radhouene
    Masci, Pier Giorgio
    Razavi, Reza
    Chiribiri, Amedeo
    Roujol, Sebastien
    MAGNETIC RESONANCE IN MEDICINE, 2024, : 2607 - 2615
  • [24] Slice-selective implementation of an adiabatic T2Prep sequence increases coronary artery conspicuity at 3T
    Sahar Soleimanifard
    Michael Schär
    Jerry L Prince
    Robert G Weiss
    Matthias Stuber
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [25] Slice-selective single scan proton COSY with dynamic nuclear polarisation
    Panek, Rafal
    Granwehr, Josef
    Leggett, James
    Koeckenberger, Walter
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2010, 12 (22) : 5771 - 5778
  • [26] A SINGLE-SHOT LOCALIZATION PULSE SEQUENCE SUITED FOR COILS WITH INHOMOGENEOUS RF FIELDS USING ADIABATIC SLICE-SELECTIVE RF PULSES
    SLOTBOOM, J
    MEHLKOPF, AF
    BOVEE, WMMJ
    JOURNAL OF MAGNETIC RESONANCE, 1991, 95 (02): : 396 - 404
  • [27] A CHEMICAL-SHIFT-INSENSITIVE SLICE-SELECTIVE RF PULSE (CHISS)
    WILLIAMS, DS
    LOWE, IJ
    JOURNAL OF MAGNETIC RESONANCE, 1991, 91 (01): : 57 - 64
  • [28] Sensitivity enhancement in slice-selective NMR experiments through polarization sharing
    Lokesh
    Suryaprakash, N.
    CHEMICAL COMMUNICATIONS, 2014, 50 (62) : 8550 - 8553
  • [29] Slice-selective FID acquisition, localized by outer volume suppression (FIDLOVS) for 1H-MRSI of the human brain at 7 T with minimal signal loss
    Henning, Anke
    Fuchs, Alexander
    Murdoch, James B.
    Boesiger, Peter
    NMR IN BIOMEDICINE, 2009, 22 (07) : 683 - 696
  • [30] The effects of slice-selective excitation/refocusing in localized spectral editing with gradient-selected double-quantum coherence transfer
    Lei, H
    Dunn, J
    JOURNAL OF MAGNETIC RESONANCE, 2001, 150 (01) : 17 - 25