A learning-based automatic segmentation and quantification method on left ventricle in gated myocardial perfusion SPECT imaging: A feasibility study

被引:82
|
作者
Wang, Tonghe [1 ,2 ]
Lei, Yang [1 ,2 ]
Tang, Haipeng [3 ]
He, Zhuo [3 ]
Castillo, Richard [1 ,2 ]
Wang, Cheng [4 ]
Li, Dianfu [4 ]
Higgins, Kristin [1 ,2 ]
Liu, Tian [1 ,2 ]
Curran, Walter J. [1 ,2 ]
Zhou, Weihua [3 ]
Yang, Xiaofeng [1 ,2 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
[2] Emory Univ, Winship Canc Inst, Atlanta, GA 30322 USA
[3] Univ Southern Mississippi, Sch Comp, 730 Beach Blvd E, Long Beach, MS 39560 USA
[4] Nanjing Med Univ, Dept Cardiol, Affiliated Hosp 1, Nanjing, Jiangsu, Peoples R China
关键词
Myocardial perfusion; SPECT; segmentation; machine learning; EJECTION FRACTION; QUANTITATIVE-ANALYSIS; QUALITY-CONTROL; INFARCTION; IMAGES; HEART; MASS;
D O I
10.1007/s12350-019-01594-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The performance of left ventricular (LV) functional assessment using gated myocardial perfusion SPECT (MPS) relies on the accuracy of segmentation. Current methods require manual adjustments that are tedious and subjective. We propose a novel machine-learning-based method to automatically segment LV myocardium and measure its volume in gated MPS imaging without human intervention. Methods We used an end-to-end fully convolutional neural network to segment LV myocardium by delineating its endocardial and epicardial surface. A novel compound loss function, which encourages similarity and penalizes discrepancy between prediction and training dataset, is utilized in training stage to achieve excellent performance. We retrospectively investigated 32 normal patients and 24 abnormal patients, whose LV myocardial contours automatically segmented by our method were compared with those delineated by physicians as the ground truth. Results The results of our method demonstrated very good agreement with the ground truth. The average DSC metrics and Hausdorff distance of the contours delineated by our method are larger than 0.900 and less than 1 cm, respectively, among all 32 + 24 patients of all phases. The correlation coefficient of the LV myocardium volume between ground truth and our results is 0.910 +/- 0.061 (P < 0.001), and the mean relative error of LV myocardium volume is - 1.09 +/- 3.66%. Conclusion These results strongly indicate the feasibility of our method in accurately quantifying LV myocardium volume change over the cardiac cycle. The learning-based segmentation method in gated MPS imaging has great promise for clinical use.
引用
收藏
页码:976 / 987
页数:12
相关论文
共 50 条
  • [41] A new method incorporating deep learning with shape priors for left ventricular segmentation in myocardial perfusion SPECT images
    Zhu, Fubao
    Li, Longxi
    Zhao, Jinyu
    Zhao, Chen
    Tang, Shaojie
    Nan, Jiaofen
    Li, Yanting
    Zhao, Zhongqiang
    Shi, Jianzhou
    Chen, Zenghong
    Han, Chuang
    Jiang, Zhixin
    Zhou, Weihua
    COMPUTERS IN BIOLOGY AND MEDICINE, 2023, 160
  • [42] Deep learning-based attenuation map generation for myocardial perfusion SPECT
    Luyao Shi
    John A. Onofrey
    Hui Liu
    Yi-Hwa Liu
    Chi Liu
    European Journal of Nuclear Medicine and Molecular Imaging, 2020, 47 : 2383 - 2395
  • [43] Feasibility and diagnostic accuracy of ECG-gated spect myocardial perfusion imaging by a two hours protocol: The myofast study
    Dunet, V.
    Costro, S.
    Sabatier, R.
    Grollier, G.
    Bouvard, G.
    Agostini, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S312 - S312
  • [44] Deep Learning-based Myocardium Segmentation using Non-Contrast-Enhanced Low-Dose CT for Myocardial Perfusion Imaging: A Feasibility Study
    Yang, Jaewon
    Chon, Kwon Su
    Akafzade, Hussein
    Bowen, Spencer
    Agusala, Kartik
    Park, Mi-Ae
    JOURNAL OF NUCLEAR MEDICINE, 2023, 64
  • [45] Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT
    Federico Caobelli
    James T. Thackeray
    Alberto Soffientini
    Frank M. Bengel
    Claudio Pizzocaro
    Ugo Paolo Guerra
    European Journal of Nuclear Medicine and Molecular Imaging, 2015, 42 : 1920 - 1928
  • [46] Feasibility of one-eighth time gated myocardial perfusion SPECT functional imaging using IQ-SPECT
    Caobelli, Federico
    Thackeray, James T.
    Soffientini, Alberto
    Bengel, Frank M.
    Pizzocaro, Claudio
    Guerra, Ugo Paolo
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 (12) : 1920 - 1928
  • [47] Feasibility of an eighth-time gated myocardial perfusion SPECT functional imaging using IQ-SPECT system
    Caobelli, F.
    Thackeray, J. T.
    Soffientini, A.
    Bengel, F. M.
    Pizzocaro, C.
    Guerra, U. P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S229 - S230
  • [48] Clinical Feasibility of Deep Learning-Based Attenuation Correction Models for Tl-201 Myocardial Perfusion SPECT
    Lim, Sungjoo
    Park, Yong-Jin
    Lee, Su Jin
    An, Young-Sil
    Yoon, Joon-Kee
    CLINICAL NUCLEAR MEDICINE, 2024, 49 (05) : 397 - 403
  • [49] Impact of imaging protocol on left ventricular ejection fraction using gated-SPECT myocardial perfusion imaging
    Marcassa, C.
    Giubbini, R.
    Acampa, W.
    Cittanti, C.
    Djepaxhija, O.
    Gimelli, A.
    Kokomani, A.
    Medolago, G.
    Milan, E.
    Sciagra, R.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (04) : 1292 - 1301
  • [50] Impact of imaging protocol on left ventricular ejection fraction using gated-SPECT myocardial perfusion imaging
    C. Marcassa
    R. Giubbini
    W. Acampa
    C. Cittanti
    O. Djepaxhija
    A. Gimelli
    A. Kokomani
    G. Medolago
    E. Milan
    R. Sciagrà
    Journal of Nuclear Cardiology, 2017, 24 : 1292 - 1301