A learning-based automatic segmentation and quantification method on left ventricle in gated myocardial perfusion SPECT imaging: A feasibility study

被引:82
|
作者
Wang, Tonghe [1 ,2 ]
Lei, Yang [1 ,2 ]
Tang, Haipeng [3 ]
He, Zhuo [3 ]
Castillo, Richard [1 ,2 ]
Wang, Cheng [4 ]
Li, Dianfu [4 ]
Higgins, Kristin [1 ,2 ]
Liu, Tian [1 ,2 ]
Curran, Walter J. [1 ,2 ]
Zhou, Weihua [3 ]
Yang, Xiaofeng [1 ,2 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
[2] Emory Univ, Winship Canc Inst, Atlanta, GA 30322 USA
[3] Univ Southern Mississippi, Sch Comp, 730 Beach Blvd E, Long Beach, MS 39560 USA
[4] Nanjing Med Univ, Dept Cardiol, Affiliated Hosp 1, Nanjing, Jiangsu, Peoples R China
关键词
Myocardial perfusion; SPECT; segmentation; machine learning; EJECTION FRACTION; QUANTITATIVE-ANALYSIS; QUALITY-CONTROL; INFARCTION; IMAGES; HEART; MASS;
D O I
10.1007/s12350-019-01594-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The performance of left ventricular (LV) functional assessment using gated myocardial perfusion SPECT (MPS) relies on the accuracy of segmentation. Current methods require manual adjustments that are tedious and subjective. We propose a novel machine-learning-based method to automatically segment LV myocardium and measure its volume in gated MPS imaging without human intervention. Methods We used an end-to-end fully convolutional neural network to segment LV myocardium by delineating its endocardial and epicardial surface. A novel compound loss function, which encourages similarity and penalizes discrepancy between prediction and training dataset, is utilized in training stage to achieve excellent performance. We retrospectively investigated 32 normal patients and 24 abnormal patients, whose LV myocardial contours automatically segmented by our method were compared with those delineated by physicians as the ground truth. Results The results of our method demonstrated very good agreement with the ground truth. The average DSC metrics and Hausdorff distance of the contours delineated by our method are larger than 0.900 and less than 1 cm, respectively, among all 32 + 24 patients of all phases. The correlation coefficient of the LV myocardium volume between ground truth and our results is 0.910 +/- 0.061 (P < 0.001), and the mean relative error of LV myocardium volume is - 1.09 +/- 3.66%. Conclusion These results strongly indicate the feasibility of our method in accurately quantifying LV myocardium volume change over the cardiac cycle. The learning-based segmentation method in gated MPS imaging has great promise for clinical use.
引用
收藏
页码:976 / 987
页数:12
相关论文
共 50 条
  • [21] QCard-NM: Developing a semiautomatic segmentation method for quantitative analysis of the right ventricle in non-gated myocardial perfusion SPECT imaging
    Entezarmahdi, Seyed Mohammad
    Faghihi, Reza
    Yazdi, Mehran
    Shahamiri, Negar
    Geramifar, Parham
    Haghighatafshar, Mahdi
    EJNMMI PHYSICS, 2023, 10 (01)
  • [22] QCard-NM: Developing a semiautomatic segmentation method for quantitative analysis of the right ventricle in non-gated myocardial perfusion SPECT imaging
    Seyed Mohammad Entezarmahdi
    Reza Faghihi
    Mehran Yazdi
    Negar Shahamiri
    Parham Geramifar
    Mahdi Haghighatafshar
    EJNMMI Physics, 10
  • [23] Segmentation of the left ventricle in myocardial perfusion SPECT using variational level set formulation
    Choi, Seokyoon
    Kim, Hochul
    Oh, Jangseok
    Kang, Teahoon
    Sun, Kyung
    Kim, Mingi
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3060 - +
  • [24] Deep Learning-based Method for Fully Automatic Quantification of Left Ventricle Function from Cine MR Images: A Multivendor, Multicenter Study
    Tao, Qian
    Yan, Wenjun
    Wang, Yuanyuan
    Paiman, Elisabeth H. M.
    Shamonin, Denis P.
    Garg, Pankaj
    Plein, Sven
    Huang, Lu
    Xia, Liming
    Sramko, Marek
    Tintera, Jarsolav
    de Roos, Albert
    Lamb, Hildo J.
    van der Geest, Rob J.
    RADIOLOGY, 2019, 290 (01) : 81 - 88
  • [25] Development of quantification software using model-based segmentation of left ventricular myocardium in gated myocardial SPECT
    Lee, Byeong-Il
    Lee, Jae Sung
    Lee, Dong Soo
    Nam, Sang Hee
    Choi, Hyun Ju
    Choi, Heung Kook
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2006, 83 (01) : 43 - 49
  • [26] Quantifying the effect of vertical motion of patient during gated myocardial perfusion SPECT on indices of perfusion and function of left ventricle
    Ahmadi, R.
    Qutbi, M.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2023, 42 (04): : 238 - 248
  • [27] Assessment of Left Ventricular Synchrony in Patients with Normal Gated SPECT Myocardial Perfusion Imaging
    Diaz Gonzalez, L. G.
    Ruano Perez, R.
    Diego Dominguez, M.
    Rosero Enriquez, A. S.
    Perdiguero, P.
    Merchan, S.
    Garcia-Talavera, J. R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S332 - S333
  • [28] Comparison of gated myocardial perfusion SPECT, echocardiography and equilibrium radionuclide ventriculography in the evaluation of left ventricle contractility
    Hatipoglu, Filiz
    Burak, Zeynep
    Omur, Ozgur
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2014, 42 (02): : 349 - 357
  • [29] Quantification of myocardial perfusion reserve using CZT-based dynamic SPECT: a feasibility study
    Slouwerhof, I.
    Jager, P.
    van Osch, J.
    Timmer, J.
    Slump, K.
    van Dalen, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S230 - S231
  • [30] The effect of renal transplantation on left ventricular mechanical dyssynchrony and remodeling: A prospective study based on gated SPECT myocardial perfusion imaging
    Sood, Ashwani
    Vadi, Shelvin
    Singh, Sarbpreet
    Parmar, Madan
    Malik, Dharmender
    Kaur, Komalpreet
    Sharma, Ashish
    Mittal, Bhagwant
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61