A learning-based automatic segmentation and quantification method on left ventricle in gated myocardial perfusion SPECT imaging: A feasibility study

被引:82
|
作者
Wang, Tonghe [1 ,2 ]
Lei, Yang [1 ,2 ]
Tang, Haipeng [3 ]
He, Zhuo [3 ]
Castillo, Richard [1 ,2 ]
Wang, Cheng [4 ]
Li, Dianfu [4 ]
Higgins, Kristin [1 ,2 ]
Liu, Tian [1 ,2 ]
Curran, Walter J. [1 ,2 ]
Zhou, Weihua [3 ]
Yang, Xiaofeng [1 ,2 ]
机构
[1] Emory Univ, Dept Radiat Oncol, Atlanta, GA 30322 USA
[2] Emory Univ, Winship Canc Inst, Atlanta, GA 30322 USA
[3] Univ Southern Mississippi, Sch Comp, 730 Beach Blvd E, Long Beach, MS 39560 USA
[4] Nanjing Med Univ, Dept Cardiol, Affiliated Hosp 1, Nanjing, Jiangsu, Peoples R China
关键词
Myocardial perfusion; SPECT; segmentation; machine learning; EJECTION FRACTION; QUANTITATIVE-ANALYSIS; QUALITY-CONTROL; INFARCTION; IMAGES; HEART; MASS;
D O I
10.1007/s12350-019-01594-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The performance of left ventricular (LV) functional assessment using gated myocardial perfusion SPECT (MPS) relies on the accuracy of segmentation. Current methods require manual adjustments that are tedious and subjective. We propose a novel machine-learning-based method to automatically segment LV myocardium and measure its volume in gated MPS imaging without human intervention. Methods We used an end-to-end fully convolutional neural network to segment LV myocardium by delineating its endocardial and epicardial surface. A novel compound loss function, which encourages similarity and penalizes discrepancy between prediction and training dataset, is utilized in training stage to achieve excellent performance. We retrospectively investigated 32 normal patients and 24 abnormal patients, whose LV myocardial contours automatically segmented by our method were compared with those delineated by physicians as the ground truth. Results The results of our method demonstrated very good agreement with the ground truth. The average DSC metrics and Hausdorff distance of the contours delineated by our method are larger than 0.900 and less than 1 cm, respectively, among all 32 + 24 patients of all phases. The correlation coefficient of the LV myocardium volume between ground truth and our results is 0.910 +/- 0.061 (P < 0.001), and the mean relative error of LV myocardium volume is - 1.09 +/- 3.66%. Conclusion These results strongly indicate the feasibility of our method in accurately quantifying LV myocardium volume change over the cardiac cycle. The learning-based segmentation method in gated MPS imaging has great promise for clinical use.
引用
收藏
页码:976 / 987
页数:12
相关论文
共 50 条
  • [1] A learning-based automatic segmentation and quantification method on left ventricle in gated myocardial perfusion SPECT imaging: A feasibility study
    Tonghe Wang
    Yang Lei
    Haipeng Tang
    Zhuo He
    Richard Castillo
    Cheng Wang
    Dianfu Li
    Kristin Higgins
    Tian Liu
    Walter J. Curran
    Weihua Zhou
    Xiaofeng Yang
    Journal of Nuclear Cardiology, 2020, 27 : 976 - 987
  • [2] A Learning-based Automatic Segmentation Method on Left Ventricle in SPECT Imaging
    Wang, Tonghe
    Yang, Lei
    Tang, Haipeng
    Harms, Joseph
    Wang, Cheng
    Liu, Tian
    Curran, Walter J.
    Zhou, Weihua
    Li, Dianfu
    Yang, Xiaofeng
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [3] A deep learning-based automatic segmentation method on left ventricle in dynamic myocardial perfusion using a CZT-SPECT
    Xu, Z.
    Ko, C.
    Chen, C.
    Wu, Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S350 - S350
  • [4] An Improved Method for Automatic Segmentation of the Left Ventricle in Myocardial Perfusion SPECT
    Soneson, Helen
    Ubachs, Joey F. A.
    Ugander, Martin
    Arheden, Hakan
    Heiberg, Einar
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (02) : 205 - 213
  • [5] Myocardial perfusion imaging SPECT left ventricle segmentation with graphs
    Szucs, adam Istvan
    Kari, Bela
    Partos, Oszkar
    EJNMMI PHYSICS, 2025, 12 (01):
  • [6] An automatic segmentation method with self-attention mechanism on left ventricle in gated PET/CT myocardial perfusion imaging
    Zhang, Yangmei
    Wang, Fanghu
    Wu, Huiqin
    Yang, Yuling
    Xu, Weiping
    Wang, Shuxia
    Chen, Wufan
    Lu, Lijun
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 229
  • [7] Spatial-temporal V-Net for automatic segmentation and quantification of right ventricle on gated myocardial perfusion SPECT images
    Zhao, Chen
    Shi, Shi
    He, Zhuo
    Malhotra, Saurabh
    Wang, Cheng
    Zhao, Zhongqiang
    Li, Xinli
    Wen, Haixing
    Tang, Shaojie
    Zhou, Yanli
    Zhou, Weihua
    MEDICAL PHYSICS, 2023, 50 (12) : 7415 - 7426
  • [8] Dynamic model of the left ventricle for use in simulation of myocardial perfusion SPECT and gated SPECT
    Bullich, S
    Ros, D
    Cot, A
    Falcón, C
    Muxí, A
    Pavia, J
    MEDICAL PHYSICS, 2003, 30 (08) : 1968 - 1975
  • [9] AUTOMATIC QUANTIFICATION OF EJECTION FRACTION FROM GATED MYOCARDIAL PERFUSION SPECT
    GERMANO, G
    KIAT, H
    KAVANAGH, PB
    MORIEL, M
    MAZZANTI, M
    SU, HT
    VANTRAIN, KF
    BERMAN, DS
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (11) : 2138 - 2147
  • [10] Effect of Methamphetamine on perfusion and functional indices of the left ventricle using gated myocardial perfusion SPECT
    Dabbagh, V.
    Dadpour, B.
    Afshari, R.
    Mohajeri, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S535 - S535