On the verification of the incident energy fluence in tomotherapy IMRT

被引:24
|
作者
Kapatoes, JM
Olivera, GH
Ruchala, KJ
Mackie, TR
机构
[1] TomoTherapy Inc, Middleton, WI 53562 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Wisconsin, Dept Human Oncol, Madison, WI 53706 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 11期
关键词
D O I
10.1088/0031-9155/46/11/313
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For any radiotherapy verification technique, it is desirable that issues with the accelerator, multileaf collimator and patient position be detected. In previous works, an effective method for this level of verification was presented. This paper identifies second-order issues affecting the part of the process in which the incident energy fluence is verified. These problems will affect any rotational intensity-modulated radiotherapy delivery that divides each rotation or arc into projections; however the solutions offered in this paper are specific to the method previously developed. The issues affecting the energy fluence verification method include leaf bouncing, delivery implementation and leaf latency. All three matters were found to introduce small errors in the verified energy fluence values for a small fraction of leaf states. The overall effect on the deposited dose over the course of a rotational delivery involving thousands of beam pulses per rotation is negligible. Regardless, effective correction strategies are presented; these are utilized in order to characterize both the delivered energy fluence and deposited dose as accurately as possible.
引用
下载
收藏
页码:2953 / 2965
页数:13
相关论文
共 50 条
  • [1] Uncertainties in tomotherapy IMRT verification measurements
    Cattaneo, G. M.
    Broggi, S.
    Hartmann, G.
    Pena, J.
    Fazio, F.
    Sanchez-Doblado, F.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S200 - S200
  • [2] Comparison of film based IMRT verification with EPID based fluence verification
    Depuydt, T.
    Vanstraelen, B.
    Verstraete, J.
    van den Heuvel, J. F.
    MEDICAL PHYSICS, 2006, 33 (06) : 2248 - 2248
  • [3] A spiral phantom for IMRT and tomotherapy treatment delivery verification
    Paliwal, B
    Tomé, W
    Richardson, S
    Mackie, TR
    MEDICAL PHYSICS, 2000, 27 (11) : 2503 - 2507
  • [4] IMRT fluence verification with an aSi portal imaging system
    Albrecht, C.
    Merz, T.
    Deissler, T.
    Ghilescu, V.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 102 - 102
  • [5] A new software tool for quantitative verification of IMRT fluence maps
    Gong, Jason
    Burmeister, Jay
    MEDICAL PHYSICS, 2006, 33 (06) : 2168 - 2168
  • [6] Dose verification of helical tomotherapy IMRT treatment using ArcCHECK device
    Rodriguez Romero, R.
    Sanchez Rubio, P.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (10) : 682 - 682
  • [7] Daily'in-vivo'verification of dynamically delivered IMRT fluence profiles
    Dirkx, M.
    van Zijtveld, M.
    Vermoen, R.
    Heijmen, B.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S305 - S305
  • [8] Is tomotherapy the future of IMRT?
    Beavis, AW
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (916): : 285 - 295
  • [9] Fluence is unequal to incident energy density or radiant exposure
    van Gemert, Martin J. C.
    van Leeuwen, Ton G.
    LASERS IN SURGERY AND MEDICINE, 2024, 56 (02) : 125 - 125
  • [10] Dosimetric verification of step-and-shoot and tomotherapy delivery methods for IMRT. (WIP)
    Kapulsky, A
    Rebo, I
    Ndlovu, A
    Gejerman, G
    Pipman, Y
    Hanley, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1496 - 1496