Cooling and condensation heat transfer and pressure drop of a refrigerant at high pressures in a chevron-type plate heat exchanger with high chevron angle

被引:6
|
作者
Miyata, Kazushi [1 ]
Yamasaki, Yuki [2 ]
Kurose, Kizuku [2 ]
Hamamoto, Yoshinori [1 ]
Mori, Hideo [1 ]
Umezawa, Shuichi [3 ]
机构
[1] Kyushu Univ, Dept Mech Engn, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
[2] Kyushu Univ, Grad Sch, Dept Mech Engn, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
[3] Tokyo Elect Power Co Holdings Inc, TEPCO Res Inst, Tsurumi Ku, 4-1 Egasaki Cho, Yokohama, Kanagawa 2308510, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2020年 / 7卷 / 04期
关键词
Chevron-type plate heat exchanger; Cooling heat transfer; Condensation heat transfer; High pressure; Refrigerant; FLUIDS;
D O I
10.1299/mej.20-00107
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In industrial fields, heat source over 130 degrees C are widely needed, and for this development of industrial high-temperature heat pump systems has been promoted. For the heat release process in such the heat pump systems, it is considered to use of a plate heat exchanger (PHE) in which a high pressure working refrigerant flows. In this study, to examine the effect of chevron angle on heat transfer of refrigerants flowing in chevron PHEs at supercritical pressure and high subcritical pressure, experiments were conducted using a chevron PHE with a chevron angle 75 degrees. The measured heat transfer coefficient was compared with the data of three chevron PHEs with respective chevron angles 30 degrees, 47.5 degrees and 65 degrees obtained previously. The effect of chevron angle on heat transfer at 65 degrees and more was smaller than that at less than 65 degrees, and the heat transfer coefficient in 75 degrees PHE was almost the same with that in 65 degrees PHE, considering difference in hydraulic diameter between the PHEs. Furthermore, the value of heat transfer coefficient achieved in 65 degrees or 75 degrees PHE was estimated to be almost maximum between 0 degrees to 90 degrees. On the other hand, the friction factor of 75 degrees PHE was markedly larger than that of 65 degrees PHE.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Effect of geometrical parameters on the performance of chevron type plate heat exchanger'
    Kumar, Bhupal
    Soni, Akhilesh
    Singh, S. N.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2018, 91 : 126 - 133
  • [42] ANALYTICAL STUDIES ON THE HYDRAULIC PERFORMANCE OF CHEVRON TYPE PLATE HEAT EXCHANGER
    Kumar, Bhupal
    Singh, S.
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2015, 33 (01) : 17 - 23
  • [43] Friction and Colburn factor correlations and shape optimization of chevron-type plate heat exchangers
    Lee, Jonghyeok
    Lee, Kwan-Soo
    APPLIED THERMAL ENGINEERING, 2015, 89 : 62 - 69
  • [44] Characteristics Analysis of Double Chevron-type Plate Heat Exchanges with Different Corrugation Ratios
    Guo, ChunSheng
    Du, WenJing
    Chen, Yan
    Cheng, Lin
    ADVANCED RESEARCH ON ENGINEERING MATERIALS, ENERGY, MANAGEMENT AND CONTROL, PTS 1 AND 2, 2012, 424-425 : 953 - 956
  • [45] Friction factors of power-law fluids in chevron-type plate heat exchangers
    Fernandes, Carla S.
    Dias, Ricardo P.
    Nobrega, Joao M.
    Maia, Joao M.
    JOURNAL OF FOOD ENGINEERING, 2008, 89 (04) : 441 - 447
  • [46] Numerical simulation and optimization of single-phase turbulent flow in chevron-type plate heat exchanger with sinusoidal corrugations
    Han, Weizhe
    Saleh, Khaled
    Aute, Vikrant
    Ding, Guoliang
    Hwang, Yunho
    Radermacher, Reinhard
    HVAC&R RESEARCH, 2011, 17 (02): : 186 - 197
  • [47] Heat transfer and pressure drop analysis on evaporation of refrigerant R410a in plate heat exchanger
    Qiu, Feng
    Zeng, Wei-Ping
    Gu, Bo
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2009, 43 (10): : 1612 - 1615
  • [48] Plate heat exchanger literature survey and new heat transfer and pressure drop correlations for refrigerant evaporators
    Ayub, ZH
    HEAT TRANSFER ENGINEERING, 2003, 24 (05) : 3 - 16
  • [49] Heat transfer and pressure drop during HFC refrigerant vaporisation inside a brazed plate heat exchanger
    Longo, G. A.
    Gasparella, A.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (25-26) : 5194 - 5203
  • [50] HEAT TRANSFER AND PRESSURE DROP DURING HYDROCARBON REFRIGERANT VAPORISATION INSIDE A BRAZED PLATE HEAT EXCHANGER
    Longo, Giovanni A.
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 4: HEAT TRANSFER MEASUREMENT TECHNIQUES, HEAT TRANSFER EQUIPMENT, THERMOELECTRICS, 2010, : 435 - 444