Predictors of Prolonged Hemodynamic Compromise After Valve Deployment During Transcatheter Aortic Valve Implantation

被引:7
|
作者
Iritakenishi, Takeshi [1 ]
Kamibayashi, Takahiko [1 ]
Torikai, Kei [2 ]
Maeda, Koichi [2 ]
Kuratani, Toru [2 ]
Sawa, Yoshiki [2 ]
Fujino, Yuji [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Anesthesiol & Intens Care Med, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Cardiovasc Surg, Suita, Osaka 5650871, Japan
关键词
rapid pacing; transcatheter aortic valve implantation; aortic stenosis; mixed venous oxygen saturation; VENOUS OXYGEN-SATURATION; DYSFUNCTION; MANAGEMENT; CONSENSUS; CATHETER; OXIMETRY; IMPACT; GOAL;
D O I
10.1053/j.jvca.2015.02.019
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To identify the risk factors of prolonged hemodynamic compromise caused by rapid pacing for valve deployment during transcatheter aortic valve implantation. Design: A retrospective study. Setting: Academic hospital. Participants: Forty-seven patients with severe aortic stenosis who underwent transcatheter aortic valve implantation.. Interventions: The time after the end of rapid pacing until systolic arterial pressure and SvO(2) recovery (systolic arterial pressure >90 mmHg and SvO(2) >65%) was defined as "the hemodynamic recovery time" and was measured from online anesthetic charts. The total study population was divided into 2 groups according to the recovery time (third quartile in all patients; 33 and 14 patients in the early and delayed recovery groups, respectively). Subsequently, the factors associated with prolonged hemodynamic compromise after rapid pacing for valve deployment were identified by univariate and multivariate analyses. Measurements and Main Results: Multivariate analysis identified left ventricular end-diastolic diameter (odds ratio, 0.774; 95% confidence interval, 0.608-0.915) and SvO(2) (odds ratio, 0.748; 95% confidence interval, 0.590-0.868) as independent factors associated with prolonged hemodynamic compromise after rapid pacing for valve deployment. Conclusions: SvO(2) and left ventricular end-diastolic diameter were found to be significant independent predictors of prolonged hemodynamic compromise immediately after rapid pacing for valve deployment during transcatheter aortic valve implantation. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:868 / 874
页数:7
相关论文
共 50 条
  • [41] Baseline and dobutamine stress hemodynamic physiology of the stenotic aortic valve before and after transcatheter valve implantation
    Johnson, Nils
    Zelis, Jo
    Tonino, Pim
    Houthuizen, Patrick
    Zimmermann, Frederik
    Bouwman, Arthur
    Brueren, Guus
    Johnson, Daniel
    Koolen, Jacques J.
    Korsten, Erik
    Wijnbergen, Inge
    Kirkeeide, Richard L.
    Pijls, Nico
    Gould, K. Lance
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B114 - B115
  • [42] Hemodynamic results and changes in myocardial function after transcatheter aortic valve implantation
    Gotzmann, Michael
    Lindstaedt, Michael
    Bojara, Waldemar
    Muegge, Andreas
    Germing, Alfried
    AMERICAN HEART JOURNAL, 2010, 159 (05) : 926 - 932
  • [43] PREDICTORS OF THROMBOCYTOPENIA FOLLOWING TRANSCATHETER AORTIC VALVE IMPLANTATION
    Totaro, A.
    Testa, G.
    Ienco, V.
    Busti, A.
    Massetti, M.
    Sacra, C.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2021, 23 (0C) : C77 - C77
  • [44] Micra Implantation After Transcatheter Aortic Valve Implantation
    Vera, Alberto
    Bastante, Teresa
    Alfonso, Fernando
    REVISTA ESPANOLA DE CARDIOLOGIA, 2018, 71 (06): : 485 - 485
  • [45] Pacemaker Implantation After Transcatheter Aortic Valve Implantation
    Goldenberg, Gustavo
    Kusniec, Jairo
    Kadmon, Ehud
    Golovchiner, Gregory
    Zabarsky, Ronit
    Nevzorov, Roman
    Vaknin, Hana
    Assali, Abed
    Kornowski, Ran
    Haim, Moti
    Strasberg, Boris
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 112 (10): : 1632 - 1634
  • [46] Predictors of permanent pacemaker implantation after transcatheter aortic valve implantation with the CoreValve prosthesis
    Hausen, S.
    Sinning, J. M.
    Werner, N.
    Nickenig, G.
    Grube, E.
    EUROPEAN HEART JOURNAL, 2012, 33 : 578 - 578
  • [47] Incidence, Timing, and Predictors of Valve Hemodynamic Deterioration After Transcatheter Aortic Valve Replacement Multicenter Registry
    Del Trigo, Maria
    Munoz-Garcia, Antonio J.
    Wijeysundera, Harindra C.
    Nombela-Franco, Luis
    Cheema, Asim N.
    Gutierrez, Enrique
    Serra, Vicenc
    Kefer, Joelle
    Amat-Santos, Ignacio J.
    Benitez, Luis M.
    Mewa, Jumana
    Jimenez-Quevedo, Pilar
    Alnasser, Sami
    Garcia del Blanco, Bruno
    Dager, Antonio
    Abdul-Jawad Altisent, Omar
    Puri, Rishi
    Campelo-Parada, Francisco
    Dahou, Abdellaziz
    Paradis, Jean-Michel
    Dumont, Eric
    Pibarot, Philippe
    Rodes-Cabau, Josep
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (06) : 644 - 655
  • [48] Sex-Specific Predictors of Pacemaker Implantation After Transcatheter Aortic Valve Implantation
    Iribarren, Ana C.
    Cook-Wiens, Galen
    Cingolani, Eugenio
    Ehdaie, Ashkan
    Shehata, Michael M.
    Wang, Xunzhang
    Chakravarty, Tarun
    Makkar, Raj
    Merz, C. Noel N. Bairey
    Sandhu, Roopinder
    CIRCULATION, 2023, 148
  • [49] Predictors and clinical outcomes of permanent pacemaker implantation after transcatheter aortic valve implantation
    Chen, Bing-Ying
    Huang, Ting-Feng
    Jiang, Xin-Da
    Ding, Xiao-Yan
    Zhou, Xiao-Fen
    BMC CARDIOVASCULAR DISORDERS, 2024, 24 (01):
  • [50] Aortic regurgitation after transcatheter aortic valve implantation
    Costopoulos, Charis
    Naganuma, Toru
    Latib, Azeem
    Colombo, Antonio
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2013, 11 (09) : 1089 - 1092