Predictors of Prolonged Hemodynamic Compromise After Valve Deployment During Transcatheter Aortic Valve Implantation

被引:7
|
作者
Iritakenishi, Takeshi [1 ]
Kamibayashi, Takahiko [1 ]
Torikai, Kei [2 ]
Maeda, Koichi [2 ]
Kuratani, Toru [2 ]
Sawa, Yoshiki [2 ]
Fujino, Yuji [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Anesthesiol & Intens Care Med, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Cardiovasc Surg, Suita, Osaka 5650871, Japan
关键词
rapid pacing; transcatheter aortic valve implantation; aortic stenosis; mixed venous oxygen saturation; VENOUS OXYGEN-SATURATION; DYSFUNCTION; MANAGEMENT; CONSENSUS; CATHETER; OXIMETRY; IMPACT; GOAL;
D O I
10.1053/j.jvca.2015.02.019
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To identify the risk factors of prolonged hemodynamic compromise caused by rapid pacing for valve deployment during transcatheter aortic valve implantation. Design: A retrospective study. Setting: Academic hospital. Participants: Forty-seven patients with severe aortic stenosis who underwent transcatheter aortic valve implantation.. Interventions: The time after the end of rapid pacing until systolic arterial pressure and SvO(2) recovery (systolic arterial pressure >90 mmHg and SvO(2) >65%) was defined as "the hemodynamic recovery time" and was measured from online anesthetic charts. The total study population was divided into 2 groups according to the recovery time (third quartile in all patients; 33 and 14 patients in the early and delayed recovery groups, respectively). Subsequently, the factors associated with prolonged hemodynamic compromise after rapid pacing for valve deployment were identified by univariate and multivariate analyses. Measurements and Main Results: Multivariate analysis identified left ventricular end-diastolic diameter (odds ratio, 0.774; 95% confidence interval, 0.608-0.915) and SvO(2) (odds ratio, 0.748; 95% confidence interval, 0.590-0.868) as independent factors associated with prolonged hemodynamic compromise after rapid pacing for valve deployment. Conclusions: SvO(2) and left ventricular end-diastolic diameter were found to be significant independent predictors of prolonged hemodynamic compromise immediately after rapid pacing for valve deployment during transcatheter aortic valve implantation. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:868 / 874
页数:7
相关论文
共 50 条
  • [31] Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement
    Hoyt, Matthew J.
    Hathaway, Jessica
    Palmer, Roseanne
    Beach, Michael
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (05) : 1162 - 1166
  • [32] Incidence, Predictors and Impact of Bleeding after Transcatheter Aortic Valve Implantation
    Borz, Bogdan
    Durand, Eric
    Godin, Matthieu
    Tron, Christophe
    Litzler, Pierre -Yves
    Bessou, Jean-Paul
    Canville, Alexandre
    Cribier, Alain
    Eltchaninoff, Helene
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (17) : B251 - B251
  • [33] Rates and predictors of hospital readmission after transcatheter aortic valve implantation
    Franzone, Anna
    Pilgrim, Thomas
    Arnold, Nicolas
    Heg, Dik
    Langhammer, Bettina
    Piccolo, Raffaele
    Roost, Eva
    Praz, Fabien
    Raeber, Lorenz
    Valgimigli, Marco
    Wenaweser, Peter
    Juni, Peter
    Carrel, Thierry
    Windecker, Stephan
    Stortecky, Stefan
    EUROPEAN HEART JOURNAL, 2017, 38 (28) : 2211 - 2217
  • [34] Outcomes and predictors of periprocedural stroke after transcatheter aortic valve implantation
    Castelo, Alexandra
    Grazina, Andre
    Teixeira, Barbara
    Mendonca, Tiago
    Rodrigues, Ines
    Bras, Pedro Garcia
    Ferreira, Vera Vaz
    Ramos, Ruben
    Fiarresga, Antonio
    Cacela, Duarte
    Ferreira, Rui Cruz
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2023, 32 (05):
  • [35] Prosthetic Valve Endocarditis After Transcatheter Aortic Valve Implantation
    Olsen, Niels Thue
    De Backer, Ole
    Thyregod, Hans G. H.
    Vejlstrup, Niels
    Bundgaard, Henning
    Sondergaard, Lars
    Ihlemann, Nikolaj
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (04)
  • [36] Structural valve deterioration after transcatheter aortic valve implantation
    Foroutan, Farid
    Guyatt, Gordon H.
    Otto, Catherine M.
    Siemieniuk, Reed A.
    Schandelmaier, Stefan
    Agoritsas, Thomas
    Vandvik, Per O.
    Bhagra, Sai
    Bagur, Rodrigo
    HEART, 2017, 103 (23) : 1899 - 1905
  • [37] Prosthetic valve endocarditis after transcatheter aortic valve implantation
    Sener, Erol
    Kucuker, Aslihan
    Erdogan, Kemal
    Bayram, Huseyin
    Bilgic, Abdulkadir
    Durmaz, Tahir
    Hidiroglu, Mete
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2015, 23 (01): : 119 - 121
  • [38] Predictors of conduction disturbances after transcatheter aortic valve implantation with balloon-expandable valve for bicuspid aortic valve stenosis
    Miyashita, Hirokazu
    Moriyama, Noriaki
    Yamanaka, Futoshi
    Saito, Shigeru
    Lehtola, Heidi
    Piuhola, Jarkko
    Niemela, Matti
    Laine, Mika
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (07) : 1576 - 1586
  • [39] RAPID DEPLOYMENT AORTIC VALVE SYSTEMS: THE SURGEONS' ALTERNATIVE TO TRANSCATHETER AORTIC VALVE IMPLANTATION? Reply
    Barnhart, Glenn R.
    Chitwood, W. Randolph
    Grossi, Eugene A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 154 (05): : 1568 - 1569
  • [40] Prosthetic Valve Escaping During Transcatheter Aortic Valve Implantation
    Furukawa, Nobuyuki
    Scholtz, Werner
    Scholtz, Smita
    Faber, Lothar
    Ensminger, Stephan
    Gummert, Jan
    Boergermann, Jochen
    INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2015, 10 (06) : 425 - 427