Diagnostic accuracy of two software modalities for detection of caries lesions in digital radiographs from four dental systems

被引:9
|
作者
Hintze, H [1 ]
机构
[1] Univ Aarhus, Sch Dent, Dept Oral Radiol, Fac Hlth Sci, DK-8000 Aarhus C, Denmark
关键词
dental caries; radiography; dental; digital; ROC curve; diagnostic test;
D O I
10.1259/dmfr/50356588
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare the caries diagnostic accuracy of two software modalities used in the assessment of digital radiographs obtained with four different dental systems, and to evaluate whether the software used for image assessment influenced the mutual comparison of those four dental systems relating to their caries diagnostic accuracy. Methods: Under in vitro and standardized conditions 122 teeth (with 228 unrestored approximal and 99 occlusal Surfaces) were radiographed in blocks of 3 test teeth and 2 non-test teeth using two storage phosphor plate systems: Digora (Soredex. Helsinki, Finland) and DenOptix (Gendex, Dentsply, Milan, Italy) and two charge coupled device (CCD)-based sensor systems: Dixi (Planmeca, Helsinki, Finland) and Sidexis (Sirona, Bensheim, Germany). The images were displayed and examined in two software modalities: their own dedicated software and a general software. Three observers examined all images for the presence of approximal enamel and dentine and occlusal dentine caries lesions using a 5-point confidence scale. The true presence of caries was validated by ground section histology. The diagnostic accuracy of the software modalities was expressed as ROC curve areas (A(z)) and differences between modalities were tested by paired t-test. Comparison of systems was analysed by post hoc t-test. Results: Results of approximal and occlusal surfaces assessed together revealed nearly identical mean A(z) with the two software modalities on images obtained with the Digora (A(z) = 0.71) and DenOptix (A(z) = 0.72) systems. On Dixi images the mean A(z) was 0.75 using the system's own software and 0.73 using the general software. On Sidexis images the corresponding mean A(z)s were 0.79 and 0.75. None of those differences were sionificant. Conclusion: No significant difference in caries diagnostic accuracy was found between two software modalities used for examination of digital radiographs obtained with four different digital systems, and the software modality did not influence the mutual rank of the four systems relating to their diagnostic accuracy.
引用
收藏
页码:78 / 82
页数:5
相关论文
共 50 条
  • [41] Comparison of the Diagnostic Accuracy of an AI-Based System for Dental Caries Detection and Clinical Evaluation Conducted by Dentists
    Kwiatek, Jakub
    Lesna, Marta
    Piskorz, Wiktor
    Kaczewiak, Justyna
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (05)
  • [42] Evaluation of diagnostic accuracy of CBCT and intraoral radiography for proximal caries detection in the presence of different dental restoration materials
    Farzaneh Mosavat
    Elham Ahmadi
    Saba Amirfarhangi
    Niyousha Rafeie
    BMC Oral Health, 23
  • [43] Effect of two X-ray tube voltages on detection of approximal caries in digital radiographs. An in vitro study
    Hellen-Halme, Kristina
    CLINICAL ORAL INVESTIGATIONS, 2011, 15 (02) : 209 - 213
  • [44] Effect of two X-ray tube voltages on detection of approximal caries in digital radiographs. An in vitro study
    Kristina Hellén-Halme
    Clinical Oral Investigations, 2011, 15 : 209 - 213
  • [45] The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study
    R. Menem
    I. Barngkgei
    N. Beiruti
    I. Al Haffar
    Easter Joury
    Lasers in Medical Science, 2017, 32 : 621 - 628
  • [46] The diagnostic accuracy of a laser fluorescence device and digital radiography in detecting approximal caries lesions in posterior permanent teeth: an in vivo study
    Menem, R.
    Barngkgei, I.
    Beiruti, N.
    Al Haffar, I.
    Joury, Easter
    LASERS IN MEDICAL SCIENCE, 2017, 32 (03) : 621 - 628
  • [47] In vitro comparison of four different dental X-ray films and direct digital radiography for proximal caries detection
    Alkurt, M. T.
    Peker, I.
    Bala, O.
    Altunkaynak, B.
    OPERATIVE DENTISTRY, 2007, 32 (05) : 504 - 509
  • [48] COMPARISON OF THE DIAGNOSTIC ACCURACY OF DIFFERENT IMAGE PROCESSING TECHNIQUES FOR DETECTION OF BONY LESIONS IN INDIRECT DIGITAL RADIOGRAPHY
    Siahtiri, S.
    Mehrabi, A.
    Ghorani, N.
    Mohagheghi, S. A.
    ANNALS OF DENTAL SPECIALTY, 2018, 6 (04): : 428 - 432
  • [49] A comparison of the diagnostic accuracy of bitewing, periapical, unfiltered and filtered digital panoramic images for approximal caries detection in posterior teeth
    Akarslan, Z. Z.
    Akdevelioglu, M.
    Gungor, K.
    Erten, H.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (08) : 458 - 463
  • [50] Malignant lesions on mammography: accuracy of two different computer-aided detection systems
    Lobbes, Marc
    Smidt, Marjolein
    Keymeulen, Kristien
    Girometti, Rossano
    Zuiani, Chiara
    Beets-Tan, Regina
    Wildberger, Joachim
    Boetes, Carla
    CLINICAL IMAGING, 2013, 37 (02) : 283 - 288