Diagnostic accuracy of two software modalities for detection of caries lesions in digital radiographs from four dental systems

被引:9
|
作者
Hintze, H [1 ]
机构
[1] Univ Aarhus, Sch Dent, Dept Oral Radiol, Fac Hlth Sci, DK-8000 Aarhus C, Denmark
关键词
dental caries; radiography; dental; digital; ROC curve; diagnostic test;
D O I
10.1259/dmfr/50356588
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To compare the caries diagnostic accuracy of two software modalities used in the assessment of digital radiographs obtained with four different dental systems, and to evaluate whether the software used for image assessment influenced the mutual comparison of those four dental systems relating to their caries diagnostic accuracy. Methods: Under in vitro and standardized conditions 122 teeth (with 228 unrestored approximal and 99 occlusal Surfaces) were radiographed in blocks of 3 test teeth and 2 non-test teeth using two storage phosphor plate systems: Digora (Soredex. Helsinki, Finland) and DenOptix (Gendex, Dentsply, Milan, Italy) and two charge coupled device (CCD)-based sensor systems: Dixi (Planmeca, Helsinki, Finland) and Sidexis (Sirona, Bensheim, Germany). The images were displayed and examined in two software modalities: their own dedicated software and a general software. Three observers examined all images for the presence of approximal enamel and dentine and occlusal dentine caries lesions using a 5-point confidence scale. The true presence of caries was validated by ground section histology. The diagnostic accuracy of the software modalities was expressed as ROC curve areas (A(z)) and differences between modalities were tested by paired t-test. Comparison of systems was analysed by post hoc t-test. Results: Results of approximal and occlusal surfaces assessed together revealed nearly identical mean A(z) with the two software modalities on images obtained with the Digora (A(z) = 0.71) and DenOptix (A(z) = 0.72) systems. On Dixi images the mean A(z) was 0.75 using the system's own software and 0.73 using the general software. On Sidexis images the corresponding mean A(z)s were 0.79 and 0.75. None of those differences were sionificant. Conclusion: No significant difference in caries diagnostic accuracy was found between two software modalities used for examination of digital radiographs obtained with four different digital systems, and the software modality did not influence the mutual rank of the four systems relating to their diagnostic accuracy.
引用
收藏
页码:78 / 82
页数:5
相关论文
共 50 条
  • [31] Observers' use of image enhancement in assessing caries in radiographs taken by four intra-oral digital systems
    Gotfredsen, E
    Wenzel, A
    Grondahl, HG
    DENTOMAXILLOFACIAL RADIOLOGY, 1996, 25 (01) : 34 - 38
  • [32] Approximal Caries Detection by DIFOTI: In Vitro Comparison of Diagnostic Accuracy/Efficacy with Film and Digital Radiography
    Astvaldsdottir, A.
    Ahlund, K.
    Holbrook, W. P.
    de Verdier, B.
    Tranaeus, S.
    INTERNATIONAL JOURNAL OF DENTISTRY, 2012, 2012
  • [33] Diagnostic accuracy of dental caries detection using ensemble techniques in deep learning with intraoral camera images
    Kang, Sohee
    Shon, Byungeun
    Park, Eun Young
    Jeong, Sungmoon
    Kim, Eun-Kyong
    PLOS ONE, 2024, 19 (09):
  • [34] Detection of dental caries under fixed dental prostheses by analyzing digital panoramic radiographs with artificial intelligence algorithms based on deep learning methods
    Ayhan, Betuel
    Ayan, Enes
    Atsu, Saadet
    BMC ORAL HEALTH, 2025, 25 (01):
  • [35] A Comparative Study on Diagnostic Accuracy of Colour Coded Digital Images, Direct Digital Images and Conventional Radiographs for Periapical Lesions - An In Vitro Study
    Pati, Abhishek Ranjan
    Mubeen
    Vijayalakshmi, K. R.
    Bhuyan, Sanat Kumar
    Panigrahi, Rajat G.
    Priyadarshini, Smita R.
    Misra, Satyaranjan
    Singh, Chandravir
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2014, 8 (11) : ZC55 - ZC59
  • [36] Clinical Accuracy of Two Different Criteria for the Detection of Caries Lesions around Restorations in Primary Teeth
    Pereira Moro, Bruna Lorena
    Antunes Pontes, Laura Regina
    Maia, Haline Cunha
    de Freitas, Raiza Dias
    Tedesco, Tamara Kerber
    Raggio, Daniela Procida
    Braga, Mariana Minatel
    Ekstrand, Kim Rud
    Pettorossi Imparato, Jose Carlos
    Sergio Cenci, Maximiliano
    Mendes, Fausto Medeiros
    CARIES RESEARCH, 2022, 56 (02) : 98 - 108
  • [37] Comparing diagnostic accuracy of γ camera coincidence systems and PET for detection of lung lesions
    Mullani, NA
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 959 - 960
  • [38] Comparing the accuracy of two machine learning models in detection and classification of periapical lesions using periapical radiographs
    Viet, Do Hoang
    Son, Le Hoang
    Tuyen, Do Ngoc
    Tuan, Tran Manh
    Thang, Nguyen Phu
    Ngoc, Vo Truong Nhu
    ORAL RADIOLOGY, 2024, 40 (04) : 493 - 500
  • [39] Evaluation of two imaging techniques: near-infrared transillumination and dental radiographs for the detection of early approximal enamel caries
    Maia, A. M. A.
    Karlsson, L.
    Margulis, W.
    Gomes, A. S. L.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (07) : 429 - 433
  • [40] Evaluation of diagnostic accuracy of CBCT and intraoral radiography for proximal caries detection in the presence of different dental restoration materials
    Mosavat, Farzaneh
    Ahmadi, Elham
    Amirfarhangi, Saba
    Rafeie, Niyousha
    BMC ORAL HEALTH, 2023, 23 (01)