A method to obtain accurate and reproducible structural parameters from diffraction data

被引:1
|
作者
Dudka, A. P. [1 ]
机构
[1] Russian Acad Sci, Inst Crystallog, Moscow, Russia
基金
俄罗斯基础研究基金会;
关键词
reproducibility of results; structural analysis; processing of diffraction data; refinement of the structure model; multipole model; method of interexperimental minimization; CCD-detector; diffractometer calibration; half-wavelength radiation; occupation of atomic positions; absorption of radiation; nonstoichiometric crystals; KTP; piezoelectric properties; langasite; MEASUREMENT PROJECT REPORT; CRYSTAL INTENSITY PROJECT; REDUCED DATA; X-RAY; CRYSTALLOGRAPHY COMMISSION; INTERNATIONAL UNION; NEUTRON-DIFFRACTION; REFINEMENT; MODEL; ABSORPTION;
D O I
10.1134/S0022476612070025
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
We present new methods of structural analysis to obtain reproducible and accurate results. The approach is based on the comparison of measurements obtained in different experimental conditions. The methods are performed using ASTRA software including and refining various aspects of diffraction: features of diffractometers and radiation; form, size, domain structure, and elemental composition of samples; anomalous dispersion; thermal motion of atoms; and redistribution of valence electrons during chemical bonding of atoms, etc. To illustrate, we study structurally dependent piezoelectricelectric properties of langasite crystals.
引用
收藏
页码:S4 / S14
页数:11
相关论文
共 50 条
  • [31] SUePDF: a program to obtain quantitative pair distribution functions from electron diffraction data
    Dung Trung Tran
    Svensson, Gunnar
    Tai, Cheuk-Wai
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2017, 50 : 304 - 312
  • [32] THE EXTRACTION OF AN ACCURATE RHO(R) FROM DIFFRACTION DATA FOR AMORPHOUS MATERIALS
    WRIGHT, AC
    NUCLEAR INSTRUMENTS & METHODS, 1980, 176 (03): : 623 - 625
  • [33] On the errors in molecular dipole moments derived from accurate diffraction data
    Coppens, P
    Volkov, A
    Abramov, Y
    Koritsanszky, T
    ACTA CRYSTALLOGRAPHICA SECTION A, 1999, 55 : 965 - 967
  • [34] Accurate unit cell determination from rotation electron diffraction data
    Wan, Wei
    Chen, Hong
    Su, Jie
    Hovmoller, Sven
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2016, 72 : S102 - S102
  • [35] Accurate determination of crystal orientation from rotation electron diffraction data
    Wang, Bin
    Hovmoller, Sven
    Zou, Xiaodong
    Wan, Wei
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2017, 73 : C65 - C65
  • [36] ELECTROSTATIC PROPERTIES FROM ACCURATE X-RAY-DIFFRACTION DATA
    EICHHORN, K
    ACTA CRYSTALLOGRAPHICA SECTION A, 1984, 40 : C178 - C178
  • [37] Computed exophthalmometry is an accurate and reproducible method for the measuring of eyeballs' protrusion
    Afanasyeva, Daria S.
    Gushchina, Marina B.
    Gerasimov, Maxim Y.
    Borzenok, Sergey A.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (03) : 461 - 465
  • [38] On the Intrinsic Limits of the Convolution Method to Obtain the Crystallite Size Distribution from Nanopowders Diffraction
    de Avillez, Roberto Ribeiro
    Abrantes, Fernanda Goncalves
    Letichevsky, Sonia
    MATERIALS RESEARCH-IBERO-AMERICAN JOURNAL OF MATERIALS, 2018, 21 (03):
  • [39] AN EFFECTIVE APPROACH TO OBTAIN MODEL PARAMETERS FOR BJTS AND FETS FROM DATA BOOKS
    NATARAJAN, S
    IEEE TRANSACTIONS ON EDUCATION, 1992, 35 (02) : 164 - 169
  • [40] A procedure to obtain the parameters of Curie temperature distribution from thermomagnetic and magnetocaloric data
    Manchon-Gordon, A. F.
    Moreno-Ramirez, L. M.
    Ipus, J. J.
    Blazquez, J. S.
    Conde, C. F.
    Franco, V
    Conde, A.
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2019, 520