Efficient on-line setup correction strategies using plan-intent functions

被引:13
|
作者
Keller, H [1 ]
Jaffray, DA [1 ]
Rosewall, T [1 ]
White, E [1 ]
机构
[1] Princess Margaret Hosp, Dept Radiat Phys, Toronto, ON M5G 2M9, Canada
基金
加拿大健康研究院;
关键词
treatment setup variations; on-line set-up correction strategies; action levels; workload;
D O I
10.1118/1.2192580
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With the introduction of image-guided radiation therapy (IGRT) delivery systems on-line set-up correction strategies have gained in popularity. Usually, the correction workload of these strategies is high compared to off-line strategies as daily setup corrections have to be performed based on a predefined action level. In this work, it is proposed that on-line strategies must not only be judged in terms of workload but also in terms of efficacy. While workload can be easily predicted for such strategies, the efficacy must ultimately reflect the efficiency with which the original treatment plan intent is met. The purpose of this work is to investigate the tradeoff between workload and efficacy of three different on-line set-up correction strategies: The common fixed action level strategy and two novel on-line setup correction strategies, i.e., a dose-volume histogram (DVH) constraint and an equivalent uniform dose (EUD) score strategy that aim directly for better compliance with original treatment plan intent. All strategies were reformulated in terms of a score function that reflected treatment plan intent. A retrospective study was conducted on 5 prostate patients (7-field conformal, 79.8 Gy, 42 fractions). PTV margins were 10 mm except in the posterior direction (7 mm). The original treatment plan intent for these patients was defined using a set of DVH constraints. The results show that the on-line setup correction strategy based on a fixed action level of 3 mm resulted in a considerable correction workload. For larger action levels, a dose benefit (in terms of EUD) in the rectum and bladder was observed for all patients which is clinically "fortuitous" but difficult to take advantage of. In contrast, the application of the two novel strategies generally resulted in a controlled decrease of the dose to the rectum and the bladder with a smaller workload. It is concluded that using information about target anatomy and the planned dose distribution allows the design of specific correction strategies that are better tailored to the individual patient and that comply effectively with initial treatment plan intent. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1388 / 1397
页数:10
相关论文
共 50 条
  • [31] Off-line setup corrections only marginally reduce the number of on-line corrections for prostate radiotherapy using implanted gold markers
    van der Vight, Lisette P.
    van Lin, Emile N. J. Th.
    Spitters-Post, Ilse
    Visser, Andries G.
    Louwe, Robert J. W.
    RADIOTHERAPY AND ONCOLOGY, 2009, 90 (03) : 359 - 366
  • [32] ON-LINE INTELLIGENT BACKGROUND CORRECTION IN ICP-AES USING A PHOTODIODE ARRAY SPECTROMETER
    Huang Yinhui
    Zhang Zhanxia
    Qian Haowen
    Li Wenchong
    ANALYTICAL SCIENCES, 1991, 7 : 553 - 556
  • [33] An on-line UPS system with power factor correction and electric isolation using BIFRED converter
    Nasiri, Adel
    Nie, Zhong
    Bekiarov, Stoyan B.
    Emadi, Ali
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (02) : 722 - 730
  • [34] On-Line Monitoring and Error Correction in Sensor Interface Circuits Using Digital Calibration Techniques
    Heinssen, Sascha
    Hillebrand, Theodor
    Taddiken, Maike
    Paul, Steffen
    Peters-Drolshagen, Dagmar
    2018 IEEE 36TH VLSI TEST SYMPOSIUM (VTS 2018), 2018,
  • [35] Focal-plane on-line nonuniformity correction using floating-gate adaptation
    Cohen, M
    Cauwenberghs, G
    ISCAS 2000: IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS - PROCEEDINGS, VOL V: EMERGING TECHNOLOGIES FOR THE 21ST CENTURY, 2000, : 153 - 156
  • [36] An on-line UPS system with power factor correction and electric isolation using BIFRED converter
    Nie, Z
    Bekiarov, SB
    Emadi, A
    IECON'03: THE 29TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1 - 3, PROCEEDINGS, 2003, : 361 - 366
  • [37] On-line correction of beam portals in the treatment of prostate cancer using an endorectal balloon device
    Ciernik, IF
    Baumert, BG
    Egli, P
    Glanzmann, C
    Lütolf, UM
    RADIOTHERAPY AND ONCOLOGY, 2002, 65 (01) : 39 - 45
  • [38] A Bayesian approach to management of setup error and organ motion using off-line monitoring and correction
    Brame, R
    Mageras, G
    Lovelock, M
    Hua, C
    Zelefsky, M
    Ling, C
    MEDICAL PHYSICS, 2003, 30 (06) : 1473 - 1473
  • [39] On-line Transient Stability Detection Using Intelligent Systems with Energy Functions Based Inputs
    Shabani, Hamid Reza
    Kalantar, Mohsen
    2019 54TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2019,
  • [40] Efficient dealing with spectrum line profiles using complex rational functions
    Humlicek, Josef
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2010, 111 (11): : 1543 - 1544