An on-line UPS system with power factor correction and electric isolation using BIFRED converter

被引:3
|
作者
Nie, Z [1 ]
Bekiarov, SB [1 ]
Emadi, A [1 ]
机构
[1] IIT, Elect Power & Power Elect Ctr, Grainger Power Elect & Motor Drives Lab, Chicago, IL 60616 USA
关键词
battery chargers; BIFRED converter; uninterruptible power supply systems; unity power factor;
D O I
10.1109/IECON.2003.1280007
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents design consideration and performance analysis of an on-line, low-cost, high performance single-phase Uninterruptible Power Supply (UPS) system based on Boost Integrated Flyback Rectifier/Energy storage DC/DC (BIFRED) converter. The system consists of an isolated AC/DC BIFRED converter, a bi-directional DC/DC converter, and a DC/AC inverter. It has input power factor correction, electric isolation of the input from the output, and control simplicity. Detailed circuit operation, analysis, as well as simulation and experiment results are presented.
引用
下载
收藏
页码:361 / 366
页数:6
相关论文
共 50 条
  • [1] An on-line UPS system with power factor correction and electric isolation using BIFRED converter
    Nasiri, Adel
    Nie, Zhong
    Bekiarov, Stoyan B.
    Emadi, Ali
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (02) : 722 - 730
  • [2] High frequency isolation on-line UPS system for low power applications
    Torrico-Bascope, Rene P.
    Bezerra, Luiz D.
    Torrico-Bascope, Grover V.
    Oliveira, Demercil de S., Jr.
    Branco, Carlos G. C.
    Barreto, Luiz H. C.
    APEC 2008: TWENTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-4, 2008, : 1296 - +
  • [3] PROPOSAL OF A 5KVA SINGLE-PHASE ON-LINE UPS WITH HIGH FREQUENCY ISOLATION AND POWER FACTOR CORRECTION
    Bascope, Rene P. T.
    Branco, Carlos G. C.
    Cruz, Cicero M. T.
    de Oliveira, Eduardo F.
    Sousa, Gean J. M.
    2009 BRAZILIAN POWER ELECTRONICS CONFERENCE, VOLS 1 AND 2, 2009, : 520 - 528
  • [4] Power factor correction of a single-phase on-line UPS with the half-bridge inverter
    Chen, YT
    PROCEEDINGS OF THE 1996 IEEE IECON - 22ND INTERNATIONAL CONFERENCE ON INDUSTRIAL ELECTRONICS, CONTROL, AND INSTRUMENTATION, VOLS 1-3, 1996, : 1826 - 1831
  • [5] On-Line Electric Vehicle using Inductive Power Transfer System
    Lee, Sungwoo
    Huh, Jin
    Park, Changbyung
    Choi, Nam-Sup
    Cho, Gyu-Hyeoung
    Rim, Chun-Taek
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 1598 - 1601
  • [6] Design and implementation of highly efficient UPS charging system with single stage power factor correction using SEPIC converter
    Sivamani, D.
    Ramkumar, R.
    Ali, A. Nazar
    Shyam, D.
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 1809 - 1819
  • [7] An On-line Electric Power Distribution System Simulator
    Dharmawardena, Hasala
    Venayagamoorthy, Ganesh K.
    2018 CLEMSON UNIVERSITY POWER SYSTEMS CONFERENCE (PSC), 2018,
  • [8] On-line estimation of electric power system active loads
    Gursoy, Ekrem
    Niebur, Dagmar
    2006 IEEE INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORK PROCEEDINGS, VOLS 1-10, 2006, : 1689 - +
  • [9] Novel adaptive hysteresis band current control using a DSP for a power factor corrected on-line UPS
    Qin, Yu
    Du, Shanshan
    IECON Proceedings (Industrial Electronics Conference), 1997, 1 : 208 - 212
  • [10] Novel adaptive hysteresis band current control using a DSP for a Power Factor Corrected on-line ups
    Qin, Y
    Du, SS
    IECON '97 - PROCEEDINGS OF THE 23RD INTERNATIONAL CONFERENCE ON INDUSTRIAL ELECTRONICS, CONTROL, AND INSTRUMENTATION, VOLS. 1-4, 1997, : 208 - 212