Independent verification of gantry angle for pre-treatment VMAT QA using EPID

被引:17
|
作者
Adamson, Justus [1 ]
Wu, Qiuwen [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27707 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 20期
关键词
MODULATED ARC THERAPY; DOSIMETRIC VERIFICATION; QUALITY-ASSURANCE; IMRT; RADIATION; DELIVERY; IMAT; TOOL;
D O I
10.1088/0031-9155/57/20/6587
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a method to incorporate independent verification of gantry angle for electronic portal imaging device (EPID)-based pre-treatment quality assurance (QA) of clinical volumetric modulated arc therapy (VMAT) plans. Gantry angle is measured using projections in the EPID of a custom phantom placed on the couch and the treatment plan is modified so as to be incident on the phantom with a portion of the beam that is collimated in the clinical plan. For our implementation, collimator and couch angles were set to zero and the inferior jaw and two most inferior multi-leaf collimator pairs were opened for the entire QA delivery. A phantom containing five gold coils was used to measure the gantry rotation through which each portal image was acquired. We performed the EPID QA for ten clinical plans and evaluated accuracy of gantry angle measurement, scatter incident on the imager due to the phantom, inter-image pixel linearity and inter-and intra-image noise. The gantry angle could be measured to within 0.0 +/- 0.3 degrees for static gantry and 0.2 +/- 0.2 degrees for arc acquisitions. Scatter due to the presence of the phantom was negligible. The procedure was shown to be feasible and adds gantry angle to the treatment planning parameters that can be verified by EPID-based pre-treatment VMAT QA.
引用
下载
收藏
页码:6587 / 6600
页数:14
相关论文
共 50 条
  • [41] A pre-treatment verification method for intensity-modulated photon beams using VERO machine EPID
    Frigerio, M.
    Bonfanti, P.
    Ostinelli, A.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S849 - S850
  • [42] Evaluating Pre-Treatment IMRT & VMAT QA Techniques Quantitatively Using Receiver Operating Characteristic (ROC) Analysis
    Mitchell, A.
    Adamson, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [43] Using EPID pre-treatment dosimetry to solve a clinical problem
    McDermott, LN
    Wendling, M
    Stroom, J
    van Asselen, B
    van Herk, M
    Mijnheer, BJ
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S65 - S66
  • [44] Sensitivity of ASi EPID to Delivery Errors for Pre Treatment Verification of Lung SBRT VMAT Plans
    Alharthi, T.
    Arumugam, S.
    Vial, P.
    Holloway, L.
    Thwaites, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E324 - E324
  • [45] Applying TG-218 Methodology to Large Field VMAT QA Using a Gantry-Resolved EPID-Based Technique
    Cardoso, P.
    Wu, Q.
    Liang, B.
    Wei, R.
    MEDICAL PHYSICS, 2019, 46 (06) : E604 - E604
  • [46] Dosimetric pre-treatment IMRT verification with a new CCD camera based fluoroscopic EPID
    Pasma, KL
    Bolt, RA
    Mestrom, LHM
    Huizenga, H
    Bal, M
    Spies, L
    Visser, AG
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S115 - S115
  • [47] PRE-TREATMENT DOSIMETRIC VERIFICATION OF RAPIDARC TREATMENTS WITH AN ASI EPID AND THE GLAAS ALGORITHM.
    Nicolini, G.
    Fogliata, A.
    Vanetti, E.
    Clivio, A.
    Korreman, S.
    Cozzi, L.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S25 - S25
  • [48] Independent MU Calculation for Pre-Treatment Verification of TomoTherapy StatRT
    Nyiri, B.
    Gerig, L.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [49] A Complete set of VMAT machine-specific QA tests using EPID
    Mestrovic, A.
    MEDICAL PHYSICS, 2012, 39 (07) : 4643 - 4643
  • [50] Gantry angle dependence in IMRT pre-treatment patient-specific quality controls
    Monti, Angelo Filippo
    Berlusconi, Chiara
    Gelosa, Stefania
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (02): : 204 - 207