Independent verification of gantry angle for pre-treatment VMAT QA using EPID

被引:17
|
作者
Adamson, Justus [1 ]
Wu, Qiuwen [1 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC 27707 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 20期
关键词
MODULATED ARC THERAPY; DOSIMETRIC VERIFICATION; QUALITY-ASSURANCE; IMRT; RADIATION; DELIVERY; IMAT; TOOL;
D O I
10.1088/0031-9155/57/20/6587
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a method to incorporate independent verification of gantry angle for electronic portal imaging device (EPID)-based pre-treatment quality assurance (QA) of clinical volumetric modulated arc therapy (VMAT) plans. Gantry angle is measured using projections in the EPID of a custom phantom placed on the couch and the treatment plan is modified so as to be incident on the phantom with a portion of the beam that is collimated in the clinical plan. For our implementation, collimator and couch angles were set to zero and the inferior jaw and two most inferior multi-leaf collimator pairs were opened for the entire QA delivery. A phantom containing five gold coils was used to measure the gantry rotation through which each portal image was acquired. We performed the EPID QA for ten clinical plans and evaluated accuracy of gantry angle measurement, scatter incident on the imager due to the phantom, inter-image pixel linearity and inter-and intra-image noise. The gantry angle could be measured to within 0.0 +/- 0.3 degrees for static gantry and 0.2 +/- 0.2 degrees for arc acquisitions. Scatter due to the presence of the phantom was negligible. The procedure was shown to be feasible and adds gantry angle to the treatment planning parameters that can be verified by EPID-based pre-treatment VMAT QA.
引用
下载
收藏
页码:6587 / 6600
页数:14
相关论文
共 50 条
  • [21] Performance Characterization and Clinical Implementation of IQM for Pre-treatment QA of VMAT
    Farrokhkish, Makan
    Heaton, Robert
    Norrlinger, Bern
    Wang, Yinkun
    Islam, Mohammad
    MEDICAL PHYSICS, 2019, 46 (11) : 5376 - 5376
  • [22] IS GAMMA INDEX EVALUATION FOR IMRT PRE-TREATMENT QA AFFECTED BY GANTRY ANGLES?
    Gelosa, S.
    Monti, A. F.
    Berlusconi, C.
    Cappelletti, P.
    Frigerio, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S214 - S214
  • [23] First clinical experience with pre-treatment and in vivo IMRT verification using EPID dosimetry
    McDermott, LN
    Wendling, M
    Sonke, J
    Stroom, J
    van Asselen, B
    van Herk, M
    Mijnheer, B
    MEDICAL PHYSICS, 2005, 32 (06) : 2090 - 2090
  • [24] Verification of the Accuracy of a Commercial Pre-Treatment IM QA Software
    Gifford, K.
    Hunter, L.
    Ballo, M.
    Kirsner, S.
    Mason, B.
    Nelson, C.
    MEDICAL PHYSICS, 2011, 38 (06) : 3586 - +
  • [25] Verification of pre-treatment DVH measurements for individual plan QA
    Stroom, J.
    Boita, J.
    Rodrigues, M.
    Greco, C.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S218 - S219
  • [26] IMRT DOSIMETRY: DIRECT DOSE TO WATER DOSIMETRY FOR PRE-TREATMENT VERIFICATION USING A MODIFIED EPID
    Gustavsson, H.
    Vial, P.
    Kuncic, Z.
    Baldock, C.
    Greer, P.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S213 - S213
  • [27] Pre-treatment verification using 3D dose reconstruction based on EPID measurements
    van Elmpt, W.
    Nijsten, S.
    Mijnheer, B.
    Dekker, A.
    Lambin, P.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S156 - S157
  • [28] Pre-treatment QA for VMAT flattening filter free beams with portal imager using GLAAS algorithm
    Vanetti, E.
    Clivio, A.
    Fogliata, A.
    Fenoglietto, P.
    Krauss, H.
    Cozzi, L.
    Nicolini, G.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (12) : 1076 - 1076
  • [29] EPID-based 3D dosimetry for pre-treatment FFF VMAT stereotactic body radiotherapy plan verification using dosimetry Check™
    Chendi, Agnese
    Botti, Andrea
    Orlandi, Matteo
    Sghedoni, Roberto
    Iori, Mauro
    Cagni, Elisabetta
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 81 : 227 - 236
  • [30] Multi-centre audit of VMAT planning and pre-treatment verification
    Jurado-Bruggeman, Diego
    Hernandez, Victor
    Saez, Jordi
    Navarro, David
    Pino, Francisco
    Martinez, Tatiana
    Alayrach, Maria-Elena
    Ailleres, Norbert
    Melero, Alejandro
    Jornet, Nuria
    RADIOTHERAPY AND ONCOLOGY, 2017, 124 (02) : 302 - 310