New configuration of a membrane bioreactor for effective control of membrane fouling and nutrients removal in wastewater treatment

被引:15
|
作者
Kim, Jun-Young [2 ]
Chang, In-Soung [1 ]
Park, Hun-Hwee [1 ]
Kim, Chang-Yong [3 ]
Kim, Jong-Bum [3 ]
Oh, Ji-Hyun [3 ]
机构
[1] Hoseo Univ, Dept Environm Engn, Asan 336795, South Korea
[2] Hoseo Univ, Dept Semicond & Display Engn, Asan 336795, South Korea
[3] GS Construct, Seoul 135985, South Korea
关键词
Aeration; Anoxic tank; Membrane bioreactor; Membrane fouling;
D O I
10.1016/j.desal.2007.11.022
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Excess aeration to membrane surface is common for controlling membrane fouling in a submerged membrane bioreactor (MBR) system, but significant energy is consumed for excess air production. Therefore, an alternative strategy for membrane fouling control is currently needed. A new configuration of MBR was proposed in this study to control membrane fouling effectively. To reduce biosolids concentration near the membrane surface, the position of the membrane module in MBR was elevated from the bottom to the top in the reactor. This could divide the reactor to two different zones: upper and lower zone. Air was not supplied at the lower zone whereas aeration was given to the upper zone where the membrane filtration was carried out. Biosolids concentration was reduced in the upper zone because the mixed liquor was settled down to the lower zone. Membrane fouling could be lessened in the upper zone due to the reduced biosolids concentration. Therefore, to verify if this new configuration of MBR could mitigate membrane fouling, the effect of changing vertical position of the membrane module in MBR on membrane fouling was investigated. Prior to verification the effect of elevation of membrane module on membrane fouling, influence of MLSS concentration on membrane fouling was investigated first. Transmembrane pressure (TMP) increase became steep as MLSS concentration increased. And the immersed membrane module was elevated from the bottom to the top of the MBR. When the upper membrane was located in the bioreactor, less membrane fouling was observed. This could demonstrate a possibility of new MBR design to control membrane fouling. In addition, reduced dissolved oxygen level in the returned sludge to anoxic tank could increase denitrification efficiency if this configuration is directly applied to biological nutrient removal processes.
引用
下载
收藏
页码:153 / 161
页数:9
相关论文
共 50 条
  • [41] Biochar Addition in Membrane Bioreactor Enables Membrane Fouling Alleviation and Nitrogen Removal Improvement for Low C/N Municipal Wastewater Treatment
    Wang, Kanming
    Ye, Qiaoqiao
    Shen, Yuxiang
    Wang, Yajing
    Hong, Qiankun
    Zhang, Chenlong
    Liu, Min
    Wang, Hongyu
    MEMBRANES, 2023, 13 (02)
  • [42] Use of chemical coagulants to control fouling potential for wastewater membrane Bioreactor processes
    Fan, Fengshen
    Zhou, Hongde
    Husain, Hadi
    WATER ENVIRONMENT RESEARCH, 2007, 79 (09) : 952 - 957
  • [43] Mechanistic insights into simultaneous reversible and irreversible membrane fouling control in a vibrating anaerobic membrane bioreactor for sustainable municipal wastewater treatment
    Wang, Chuansheng
    Ding, Meiyue
    Ng, Tze Chiang Albert
    Ng, How Yong
    CHEMICAL ENGINEERING JOURNAL, 2023, 466
  • [44] Application of a specific membrane fouling control enhancer in membrane bioreactor for real municipal wastewater treatment: Sludge characteristics and microbial community
    Deng, Lijuan
    Guo, Wenshan
    Ngo, Huu Hao
    Wang, Xiaochang C.
    Hu, Yisong
    Chen, Rong
    Cheng, Dongle
    Guo, Shengquan
    Cao, Yunyang
    BIORESOURCE TECHNOLOGY, 2020, 312
  • [45] Membrane Fouling and Control Approaches in Membrane Bioreactor Systems: A Review
    Mustafa Turan
    Water, Air, & Soil Pollution, 2025, 236 (3)
  • [46] Membrane biofilm development improves COD removal in anaerobic membrane bioreactor wastewater treatment
    Smith, Adam L.
    Skerlos, Steven J.
    Raskin, Lutgarde
    MICROBIAL BIOTECHNOLOGY, 2015, 8 (05): : 883 - 894
  • [47] Control of membrane fouling in membrane bioreactor process by coagulant addition
    Mishima, I.
    Nakajima, J.
    WATER SCIENCE AND TECHNOLOGY, 2009, 59 (07) : 1255 - 1262
  • [48] Membrane fouling in nanofiltration/reverse osmosis membranes coupled with a membrane bioreactor used for municipal wastewater treatment
    Ogawa, Naoko
    Kimura, Katsuki
    Watanabe, Yoshimasa
    DESALINATION AND WATER TREATMENT, 2010, 18 (1-3) : 292 - 296
  • [49] A modelling approach to study the fouling of an anaerobic membrane bioreactor for industrial wastewater treatment
    Charfi, Amine
    Thongmak, Narumol
    Benyahia, Boumediene
    Aslam, Muhammad
    Harmand, Jerome
    Ben Amar, Nihel
    Lesage, Geoffroy
    Sridang, Porntip
    Kim, Jeonghwan
    Heran, Marc
    BIORESOURCE TECHNOLOGY, 2017, 245 : 207 - 215
  • [50] Membrane fouling in an anaerobic dynamic membrane bioreactor (AnDMBR) for municipal wastewater treatment: Characteristics of membrane foulants and bulk sludge
    Zhang, Xinying
    Wang, Zhiwei
    Wu, Zhichao
    Wei, Tianye
    Lu, Fenghai
    Tong, Jun
    Mai, Suihai
    PROCESS BIOCHEMISTRY, 2011, 46 (08) : 1538 - 1544