New configuration of a membrane bioreactor for effective control of membrane fouling and nutrients removal in wastewater treatment

被引:15
|
作者
Kim, Jun-Young [2 ]
Chang, In-Soung [1 ]
Park, Hun-Hwee [1 ]
Kim, Chang-Yong [3 ]
Kim, Jong-Bum [3 ]
Oh, Ji-Hyun [3 ]
机构
[1] Hoseo Univ, Dept Environm Engn, Asan 336795, South Korea
[2] Hoseo Univ, Dept Semicond & Display Engn, Asan 336795, South Korea
[3] GS Construct, Seoul 135985, South Korea
关键词
Aeration; Anoxic tank; Membrane bioreactor; Membrane fouling;
D O I
10.1016/j.desal.2007.11.022
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Excess aeration to membrane surface is common for controlling membrane fouling in a submerged membrane bioreactor (MBR) system, but significant energy is consumed for excess air production. Therefore, an alternative strategy for membrane fouling control is currently needed. A new configuration of MBR was proposed in this study to control membrane fouling effectively. To reduce biosolids concentration near the membrane surface, the position of the membrane module in MBR was elevated from the bottom to the top in the reactor. This could divide the reactor to two different zones: upper and lower zone. Air was not supplied at the lower zone whereas aeration was given to the upper zone where the membrane filtration was carried out. Biosolids concentration was reduced in the upper zone because the mixed liquor was settled down to the lower zone. Membrane fouling could be lessened in the upper zone due to the reduced biosolids concentration. Therefore, to verify if this new configuration of MBR could mitigate membrane fouling, the effect of changing vertical position of the membrane module in MBR on membrane fouling was investigated. Prior to verification the effect of elevation of membrane module on membrane fouling, influence of MLSS concentration on membrane fouling was investigated first. Transmembrane pressure (TMP) increase became steep as MLSS concentration increased. And the immersed membrane module was elevated from the bottom to the top of the MBR. When the upper membrane was located in the bioreactor, less membrane fouling was observed. This could demonstrate a possibility of new MBR design to control membrane fouling. In addition, reduced dissolved oxygen level in the returned sludge to anoxic tank could increase denitrification efficiency if this configuration is directly applied to biological nutrient removal processes.
引用
收藏
页码:153 / 161
页数:9
相关论文
共 50 条
  • [21] Membrane fouling control in the moving carriershybrid membrane bioreactor
    Li, Zheng
    Qi, Pei-Shi
    Chen, Zhao-Bo
    Wang, Wen-Bin
    Zhongguo Kuangye Daxue Xuebao/Journal of China University of Mining and Technology, 2008, 37 (06): : 814 - 818
  • [22] Membrane fouling control in an integrated membrane-bioreactor
    Liu, Rui
    Huang, Xia
    Wang, Chengwen
    Qian, Yi
    Zhang, Miaomiao
    Huanjing Kexue/Environmental Science, 2000, 21 (02): : 58 - 61
  • [23] Membrane fouling control in anaerobic submerged membrane bioreactor
    Aslan, Mustafa
    Saatci, Yusuf
    Hanay, Ozge
    Hasar, Halil
    DESALINATION AND WATER TREATMENT, 2014, 52 (40-42) : 7520 - 7530
  • [24] Effect of cyclic aeration on fouling in submerged membrane bioreactor for wastewater treatment
    Wu, Jun
    He, Chengda
    WATER RESEARCH, 2012, 46 (11) : 3507 - 3515
  • [25] Effect of the shear intensity on fouling in submerged membrane bioreactor for wastewater treatment
    Delgado, S.
    Villarroel, R.
    Gonzalez, E.
    JOURNAL OF MEMBRANE SCIENCE, 2008, 311 (1-2) : 173 - 181
  • [26] Advanced wastewater treatment and membrane fouling control by electro-encapsulated self-forming dynamic membrane bioreactor
    Millanar-Marfa, Jessa Marie J.
    Corpuz, Mary Vermi Aizza
    Borea, Laura
    Cabreros, Carlo
    De Luna, Mark Daniel G.
    Ballesteros, Florencio, Jr.
    Vigliotta, Giovanni
    Zarra, Tiziano
    Hasan, Shadi W.
    Korshin, Gregory, V
    Buonerba, Antonio
    Belgiorno, Vincenzo
    Naddeo, Vincenzo
    NPJ CLEAN WATER, 2022, 5 (01)
  • [27] Advanced wastewater treatment and membrane fouling control by electro-encapsulated self-forming dynamic membrane bioreactor
    Jessa Marie J. Millanar-Marfa
    Mary Vermi Aizza Corpuz
    Laura Borea
    Carlo Cabreros
    Mark Daniel G. De Luna
    Florencio Jr. Ballesteros
    Giovanni Vigliotta
    Tiziano Zarra
    Shadi W. Hasan
    Gregory V. Korshin
    Antonio Buonerba
    Vincenzo Belgiorno
    Vincenzo Naddeo
    npj Clean Water, 5
  • [28] Wastewater treatment in membrane bioreactors: The use of polyelectrolytes to control membrane fouling
    Gkotsis P.
    Peleka E.
    Zamboulis D.
    Mitrakas M.
    Tolkou A.
    Zouboulis A.
    Environmental Processes, 2017, 4 (Suppl 1) : 9 - 21
  • [29] Impact of decreasing COD/N ratio on nitrogen removal and fouling in a membrane bioreactor for urban wastewater treatment
    Lahdhiri, A.
    Sid, S.
    Lesage, G.
    Heran, M.
    DESALINATION AND WATER TREATMENT, 2017, 80 : 121 - 132
  • [30] Predicting Membrane Fouling of Submerged Membrane Bioreactor Wastewater Treatment Plants Using Machine Learning
    Zhu, Yunyi
    Wang, Yuan
    Zhu, Elisabeth
    Ma, Zeyu
    Wang, Hanchen
    Chen, Chunsheng
    Guan, Jing
    Waite, T. David
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2025,