Application of Implantable Wireless Biomicrosystem for Monitoring Nerve Impedance of Rat After Sciatic Nerve Injury

被引:17
|
作者
Li, Yu-Ting [1 ]
Peng, Chih-Wei [2 ,3 ]
Chen, Lung-Tai [4 ]
Lin, Wen-Shan [4 ]
Chu, Chun-Hsun [4 ]
Chen, Jia-Jin Jason [1 ,5 ]
机构
[1] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan 701, Taiwan
[2] Taipei Med Univ, Sch Med, Dept Phys Med & Rehabil, Coll Med, Taipei 11031, Taiwan
[3] Taipei Med Univ Hosp, Dept Phys Med & Rehabil, Taipei 11031, Taiwan
[4] Ind Technol Res Inst, Microsyst Technol Ctr, Tainan 70955, Taiwan
[5] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan 701, Taiwan
关键词
Electrical stimulation; impedance measurement; implantable biomicrosystem; nerve regeneration; PERIPHERAL-NERVE; ELECTRICAL-STIMULATION; CUFF ELECTRODE; TIME-COURSE; REGENERATION; SYSTEM; REPAIR; REINNERVATION;
D O I
10.1109/TNSRE.2012.2219883
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electrical stimulation is usually applied percutaneously for facilitating peripheral nerve regeneration. However, few studies have conducted long-term monitoring of the condition of nerve regeneration. This study implements an implantable biomicrosystem for inducing pulse current for aiding nerve repair and monitoring the time-course changes of nerve impedance for assessing nerve regeneration in sciatic nerve injury rat model. For long-term implantation, a transcutaneous magnetic coupling technique is adopted for power and data transmission. For in vivo study, the implanted module was placed in the rat's abdomen and the cuff electrode was wrapped around an 8-mm sciatic nerve gap of the rat for nerve impedance measurement for 42 days. One group of animals received monophasic constant current via the cuff electrode and a second group had no stimulation between days 8-21. The nerve impedance increased to above 150% of the initial value in the nerve regeneration groups with and without stimulation whereas the group with no nerve regeneration increased to only 113% at day 42. The impedance increase in nerve regeneration groups can be observed before evident functional recovery. Also, the nerve regeneration group that received electrical stimulation had relatively higher myelinated fiber density than that of no stimulation group, 20686 versus 11417 fiber/mm(2). The developed implantable biomicrosystem is proven to be a useful experimental tool for long-term stimulation in aiding nerve fiber growth as well as impedance assessment for understanding the time-course changes of nerve regeneration.
引用
收藏
页码:121 / 128
页数:8
相关论文
共 50 条
  • [31] Pudendal Nerve Injury After a Sciatic Nerve Block by the Posterior Approach
    Bondar, Attila
    Egan, Michael
    Jochum, Denis
    Amarenco, Gerard
    Bouaziz, Herve
    ANESTHESIA AND ANALGESIA, 2010, 111 (02): : 573 - 575
  • [32] Immunological Demyelination Enhances Nerve Regeneration After Acute Transection Injury in the Adult Rat Sciatic Nerve
    Kosins, Aaron M.
    Scholz, Thomas
    Lin, Michael
    Evans, Gregory R. D.
    Keirstead, Hans S.
    ANNALS OF PLASTIC SURGERY, 2012, 68 (03) : 290 - 294
  • [33] Enhancement of nerve regeneration with nimodipine treatment after sciatic nerve injury
    Al-Saedi, Haider F.
    Panahi, Yasin
    Ghanimi, Hussein A.
    Abdolmaleki, Arash
    Asadi, Asadollah
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2023, 37 (01) : 107 - 115
  • [34] LOCAL ANESTHETIC-INDUCED NERVE INJURY IN RAT SCIATIC-NERVE
    KALICHMAN, MW
    MYERS, RR
    POWELL, HC
    JOURNAL OF NEUROPATHOLOGY AND EXPERIMENTAL NEUROLOGY, 1985, 44 (03): : 347 - 347
  • [35] Tubulization increases axonal outgrowth of rat sciatic nerve after crush injury
    Danielsson, P
    Dahlin, L
    Povlsen, B
    EXPERIMENTAL NEUROLOGY, 1996, 139 (02) : 238 - 243
  • [36] THERMAL HYPERALGESIA DEVELOPS AFTER COLD INJURY TO RAT SCIATIC-NERVE
    KLEIVE, MA
    UHLENKAMP, JA
    KAJANDER, KC
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 210 - 210
  • [37] Androgen induced acceleration of functional recovery after rat sciatic nerve injury
    Brown, TJ
    Khan, T
    Jones, KJ
    RESTORATIVE NEUROLOGY AND NEUROSCIENCE, 1999, 15 (04) : 289 - 295
  • [38] The Observation of Phenotypic Changes of Schwann Cells after Rat Sciatic Nerve Injury
    Wang, Jin
    Zhang, Peixun
    Wang, Yanhua
    Kou, Yuhui
    Zhang, Hongbo
    Jiang, Baoguo
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2010, 38 (01): : 24 - 28
  • [39] ENDONEURIAL MICROENVIRONMENT AND ACUTE NERVE CRUSH INJURY IN THE RAT SCIATIC-NERVE
    ZOCHODNE, DW
    HO, LT
    BRAIN RESEARCH, 1990, 535 (01) : 43 - 48
  • [40] Injury and repair of the soleus muscle after electrical stimulation of the sciatic nerve in the rat
    Matsuura, N
    Kawamata, S
    Ozawa, J
    Kai, S
    Sakakima, H
    Abiko, S
    ARCHIVES OF HISTOLOGY AND CYTOLOGY, 2001, 64 (04) : 393 - 400