Application of Implantable Wireless Biomicrosystem for Monitoring Nerve Impedance of Rat After Sciatic Nerve Injury

被引:17
|
作者
Li, Yu-Ting [1 ]
Peng, Chih-Wei [2 ,3 ]
Chen, Lung-Tai [4 ]
Lin, Wen-Shan [4 ]
Chu, Chun-Hsun [4 ]
Chen, Jia-Jin Jason [1 ,5 ]
机构
[1] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan 701, Taiwan
[2] Taipei Med Univ, Sch Med, Dept Phys Med & Rehabil, Coll Med, Taipei 11031, Taiwan
[3] Taipei Med Univ Hosp, Dept Phys Med & Rehabil, Taipei 11031, Taiwan
[4] Ind Technol Res Inst, Microsyst Technol Ctr, Tainan 70955, Taiwan
[5] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan 701, Taiwan
关键词
Electrical stimulation; impedance measurement; implantable biomicrosystem; nerve regeneration; PERIPHERAL-NERVE; ELECTRICAL-STIMULATION; CUFF ELECTRODE; TIME-COURSE; REGENERATION; SYSTEM; REPAIR; REINNERVATION;
D O I
10.1109/TNSRE.2012.2219883
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electrical stimulation is usually applied percutaneously for facilitating peripheral nerve regeneration. However, few studies have conducted long-term monitoring of the condition of nerve regeneration. This study implements an implantable biomicrosystem for inducing pulse current for aiding nerve repair and monitoring the time-course changes of nerve impedance for assessing nerve regeneration in sciatic nerve injury rat model. For long-term implantation, a transcutaneous magnetic coupling technique is adopted for power and data transmission. For in vivo study, the implanted module was placed in the rat's abdomen and the cuff electrode was wrapped around an 8-mm sciatic nerve gap of the rat for nerve impedance measurement for 42 days. One group of animals received monophasic constant current via the cuff electrode and a second group had no stimulation between days 8-21. The nerve impedance increased to above 150% of the initial value in the nerve regeneration groups with and without stimulation whereas the group with no nerve regeneration increased to only 113% at day 42. The impedance increase in nerve regeneration groups can be observed before evident functional recovery. Also, the nerve regeneration group that received electrical stimulation had relatively higher myelinated fiber density than that of no stimulation group, 20686 versus 11417 fiber/mm(2). The developed implantable biomicrosystem is proven to be a useful experimental tool for long-term stimulation in aiding nerve fiber growth as well as impedance assessment for understanding the time-course changes of nerve regeneration.
引用
下载
收藏
页码:121 / 128
页数:8
相关论文
共 50 条
  • [11] FUNCTIONAL ASSESSMENT AFTER SCIATIC NERVE INJURY IN A RAT MODEL
    Dinh, Paul
    Hazel, Antony
    Palispis, Winnie
    Suryadevara, Sourabh
    Gupta, Ranjan
    MICROSURGERY, 2009, 29 (08) : 644 - 649
  • [12] Selective Wireless Stimulation of Rat Sciatic Nerve
    Frederick, Rebecca A.
    Troyk, Philip R.
    Cogan, Stuart F.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 3407 - 3410
  • [13] Silver nitrate injury in the rat sciatic nerve: A model of facial nerve, injury
    Wachter, BG
    Leonetti, JP
    Lee, JM
    Wurster, RD
    Young, MRI
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2002, 127 (01) : 48 - 54
  • [14] Misdirection of regenerating motor axons after nerve injury and repair in the rat sciatic nerve model
    de Ruiter, Godard C. W.
    Malessy, Martijn J. A.
    Alaid, Awad O.
    Spinner, Robert J.
    Engelstad, JaNean K.
    Sorenson, E. J.
    Kaufman, K. R.
    Dyck, Peter J.
    Windebank, Anthony J.
    EXPERIMENTAL NEUROLOGY, 2008, 211 (02) : 339 - 350
  • [15] Misdirection of regenerating motor axons after nerve injury and repair in the rat sciatic nerve model
    de Ruiter, G. C. W.
    Malessy, M. J. A.
    Spinner, R. J.
    Alaid, A.
    Engelstad, J. K.
    Sorenson, E. J.
    Kaufman, K. R.
    Dyck, P. J.
    Windebank, A. J.
    JOURNAL OF THE PERIPHERAL NERVOUS SYSTEM, 2007, 12 : 25 - 25
  • [16] RETROGRADE AXONAL-TRANSPORT IN RAT SCIATIC-NERVE AFTER NERVE CRUSH INJURY
    FINK, DJ
    PURKISS, D
    MATA, M
    BRAIN RESEARCH BULLETIN, 1987, 19 (01) : 29 - 33
  • [17] Effect of Spp1 on nerve degeneration and regeneration after rat sciatic nerve injury
    Xingyu Liu
    Yuhua Sun
    Huaiqin Li
    Yuting Li
    Meiyuan Li
    Ying Yuan
    Shusen Cui
    Dengbing Yao
    BMC Neuroscience, 18
  • [18] Nerve Fiber Regeneration in the Rat Sciatic Nerve After Injury and Administration of Mesenchymal Stem Cells
    Petrova E.S.
    Kolos E.A.
    Neuroscience and Behavioral Physiology, 2021, 51 (4) : 513 - 518
  • [19] Effect of Spp1 on nerve degeneration and regeneration after rat sciatic nerve injury
    Liu, Xingyu
    Sun, Yuhua
    Li, Huaiqin
    Li, Yuting
    Li, Meiyuan
    Yuan, Ying
    Cui, Shusen
    Yao, Dengbing
    BMC NEUROSCIENCE, 2017, 18
  • [20] Influence of galantamine on peripheral nerve degeneration after experimental compression injury of the rat sciatic nerve
    Alagoz, Fatih
    Sahinoglu, Mert
    Billur, Deniz
    Aydin, Sevim
    Akdag, Rifat
    Karakoyun, Durmus Oguz
    Daglioglu, Ergun
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2022, 28 (03): : 242 - 248