Release of dibenzoyl peroxide from polymethyl methacrylate denture base resins: An in vitro evaluation

被引:26
|
作者
Boeckler, Arne F. [1 ]
Morton, Dean [2 ]
Poser, Sven [3 ]
Dette, Karl-Ernst [1 ]
机构
[1] Univ Halle Wittenberg, Dept Prosthodont, Fac Dent Propedeut, D-06108 Halle, Germany
[2] Univ Florida, Coll Dent, Ctr Implant Dent, Gainesville, FL USA
[3] Univ Halle Wittenberg, Inst Polymer Mat, D-06108 Halle, Germany
关键词
Allergy; Denture base acrylic resin; BPO; Hypersensitivity; PMMA; Hypoallergic; Post-polymerization;
D O I
10.1016/j.dental.2008.03.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Dibenzoyl peroxide (BPO), an initiator in polymethyl methacrylate denture base resins, has been associated with allergic reactions in human patients. This study evaluated the content of BPO in acrylic denture base materials (ADBM) prior and subsequent to recommended and additional post-polymerization, and subsequent to storage in varying solutions. The goal was to determine differences in BPO content in ADBMs, to determine whether differences are seen in BPO release over time and to test different procedures for additional BPO reduction. Methods. Three heat-polymerizing, two auto-polymerizing and a microwave polymerizing "hypoallergic" ADBM were investigated. Five samples (empty set 414.57 mg) were polymerized according to manufacturers' instructions from each of the six acrylic resins for each of the variables to be investigated. For each material the BPO content was measured as delivered by the manufacturer and subsequent to recommended and post-polymerization protocols. The BPO content was also evaluated after storage in distilled water (22 degrees C, 192 h), in artificial saliva (35 degrees C, 192 h), in ethanol, potassium permanganate and ammonium ferric(II) sulfate solutions (22 degrees C, 48 h). Results. High performance liquid chromatography (HPLC) and indirect iodometry were used to detect BPO concentrations. Significant differences were noted in BPO concentrations between the polymers as delivered from the manufacturer (0.13-1.20%), subsequent to polymerization (0.05-0.32%) and to the various treatment and storage procedures (H and U-tests, p < 0.05). The microwave polymerizing ADBM contained the lowest initial level of BPO. No reduction of BPO content was noted after 8 days of storage in artificial saliva or water. The most notable reduction (63-95%) occurred subsequent to post-polymerization cycles. Significance. BPO was detected in all investigated ADBMs. it is unlikely, under oral conditions, that BPO is released from the investigated ADBMs. The BPO concentration can be reduced effectively by additional post-polymerization. (C) 2008 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1602 / 1607
页数:6
相关论文
共 50 条
  • [21] Effect of Negative Ion Powder on the Mechanical Properties of Polymethyl Methacrylate(PMMA) Denture Base
    Liu, Wen-Juan
    Zhang, Yu-Lin
    Zhang, Kang-Tai
    Ding, Li-Li
    Zheng, Ya-Wen
    Xie, Wei-Bo
    Dou, Fang-Yu
    Liu, Bin
    INTERNATIONAL CONFERENCE ON MECHANICS AND MATERIALS ENGINEERING (ICMME 2014), 2014, : 344 - 348
  • [22] A Color Stability Comparison of Conventional and CAD/CAM Polymethyl Methacrylate Denture Base Materials
    Dayan, Cagatay
    Guven, Melahat Celik
    Gencel, Burc
    Bural, Canan
    ACTA STOMATOLOGICA CROATICA, 2019, 53 (02) : 158 - 167
  • [23] Effect of heat treatment of polymethyl methacrylate powder on mechanical properties of denture base resin
    Kawaguchi, Tomohiro
    Lassila, Lippo V. J.
    Sasaki, Hirono
    Takahashi, Yutaka
    Vallittu, Pekka K.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 39 : 73 - 78
  • [24] Comparative effects of denture cleansers on physical properties of polyamide and polymethyl methacrylate base polymers
    Durkan, Rukiye
    Ayaz, Elif Aydogan
    Bagis, Bora
    Gurbuz, Ayhan
    Ozturk, Nilgun
    Korkmaz, Fatih Mehmet
    DENTAL MATERIALS JOURNAL, 2013, 32 (03) : 367 - 375
  • [25] Evaluation of vaporized hydrogen peroxide sterilization on the in vitro efficacy of meropenem-impregnated polymethyl methacrylate beads
    Durham, Myra E.
    Elfenbein, Johanna R.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2019, 80 (01) : 45 - 50
  • [26] Evaluation of the quantity of MMA released by denture base resins
    Costa, M.
    Seabra, V.
    Amaral, A.
    Carvalho, L.
    BIODENTAL ENGINEERING, 2010, : 195 - 198
  • [27] The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials
    Polychronakis, Nick
    Dimitriadi, Maria
    Polyzois, Gregory
    Eliades, George
    JOURNAL OF APPLIED ORAL SCIENCE, 2022, 30
  • [28] Effect of fiber reinforcement on impact strength of heat polymerized polymethyl methacrylate denture base resin: in vitro study and SEM analysis
    Mowade, Tushar Krishnarao
    Dange, Shankar Pandurang
    Thakre, Mrunali Balkrushna
    Kamble, Vaibhav Deorao
    JOURNAL OF ADVANCED PROSTHODONTICS, 2012, 4 (01): : 30 - 36
  • [29] MIGRATION OF CADMIUM FROM DENTURE BASE RESINS
    ANDREOPOULOS, AG
    POLYZOIS, GL
    JOURNAL OF MATERIALS SCIENCE LETTERS, 1985, 4 (07) : 855 - 856
  • [30] In Vitro Analysis of the Mechanical Properties of Hypoallergenic Denture Base Resins
    Hinz, Sebastian
    Bensel, Tobias
    Boemicke, Wolfgang
    Boeckler, Arne F.
    MATERIALS, 2022, 15 (10)