Flow Patterns at Stented Coronary Bifurcations Computational Fluid Dynamics Analysis

被引:58
|
作者
Katritsis, Demosthenes G. [1 ]
Theodorakakos, Andreas [2 ]
Pantos, Ioannis [1 ,3 ]
Gavaises, Manolis [4 ]
Karcanias, Nicos [4 ]
Efstathopoulos, Efstathios P. [3 ]
机构
[1] Athens Euroclin, Dept Cardiol, Athens 11521, Greece
[2] Fluid Res, Athens, Greece
[3] Univ Athens, Dept Radiol, GR-10679 Athens, Greece
[4] City Univ London, Sch Engn & Math Sci, London EC1V 0HB, England
关键词
angioplasty; stents; hemodynamics; bifurcation; coronary circulation; WALL SHEAR-STRESS; PERCUTANEOUS CORONARY; ELUTING STENTS; PULSATILE FLOW; LESIONS; ARTERY; IMPLANTATION; ATHEROSCLEROSIS; HEMODYNAMICS; PREDICTORS;
D O I
10.1161/CIRCINTERVENTIONS.112.968347
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The ideal bifurcation stenting technique is not established, and data on the hemodynamic characteristics at stented bifurcations are limited. Methods and Results-We used computational fluid dynamics analysis to assess hemodynamic parameters known affect the risk of restenosis and thrombosis at coronary bifurcations after the use of various single-and double-stenting techniques. We assessed the distributions and surface integrals of the time averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (t(r)). Single main branch stenting without side branch balloon angioplasty or stenting provided the most favorable hemodynamic results (integrated values of TAWSS=4.13.10(-4) N, OSI=7.52.10(-6) m(2), t(r)=5.57.10(-4) m(2)/Pa) with bifurcational area subjected to OSI values >0.25, >0.35, and >0.45 calculated as 0.36 mm(2), 0.04 mm(2), and 0 mm(2), respectively. Extended bifurcation areas subjected to these OSI values were seen after T-stenting: 0.61 mm(2), 0.18 mm(2), and 0.02 mm(2), respectively. Among the considered double-stenting techniques, crush stenting (integrated values of TAWSS=1.18.10(-4) N, OSI=7.75.10(-6) m(2), t(r)=6.16.10(-4) m(2)/Pa) gave the most favorable results compared with T-stenting (TAWSS=0.78.10(-4) N, OSI=10.40.10(-6) m(2), t(r)=6.87.10(-4) m(2)/Pa) or the culotte technique (TAWSS=1.30.10(-4) N, OSI=9.87.10(-6) m(2), t(r)=8.78.10(-4) m(2)/Pa). Conclusions-In the studied models of computer simulations, stenting of the main branch with our without balloon angioplasty of the side branch offers hemodynamic advantages over double stenting. When double stenting is considered, the crush technique with the use of a thin-strut stent may result in improved immediate hemodynamics compared with culotte or T-stenting. (Circ Cardiovasc Interv. 2012; 5:530-539.)
引用
收藏
页码:530 / 539
页数:10
相关论文
共 50 条
  • [31] A computational fluid dynamics simulation study of coronary blood flow affected by graft placement†
    Lassaline, Jason V.
    Moon, Byung C.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 19 (01) : 16 - 20
  • [32] Fractional flow reserve derived from conventional coronary angiograms and computational fluid dynamics
    Kopanidis, Anastasios
    Pantos, Ioannis
    Theodorakakos, Andreas
    Tzanalaidou, Efthalia
    Katritsis, Demosthenes
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 190 : 187 - 189
  • [33] Computational fluid dynamics analysis of the effect of throat diameter on the fluid flow and performance of ejector
    Salehi, Mohammadreza
    Pourmahmoud, Nader
    Hassanzadeh, Amir
    Hoseinzadeh, S.
    Heyns, P. S.
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2021, 31 (03) : 733 - 752
  • [34] Flow Patterns in Carotid Webs: A Patient-Based Computational Fluid Dynamics Study
    Compagne, K. C. J.
    Dilba, K.
    Postema, E. J.
    van Es, A. C. G. M.
    Emmer, B. J.
    Majoie, C. B. L. M.
    van Zwam, W. H.
    Dippel, D. W. J.
    Wentzel, J. J.
    van der Lugt, A.
    Gijsen, F. J. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (04) : 703 - 708
  • [35] Prediction of complex flow patterns in intracranial atherosclerotic disease using computational fluid dynamics
    Clemens, M. Schirmer
    Malek, Adel M.
    NEUROSURGERY, 2007, 61 (04) : 842 - 851
  • [36] Computational fluid dynamics analysis of the pump parameters in the helical flow pump
    Hosoda, Kyohei
    Ishii, Kohei
    Isoyama, Takashi
    Saito, Itsuro
    Inoue, Yusuke
    Ariyoshi, Kouki
    Ono, Toshiya
    Nakagawa, Hidemoto
    Imachi, Kou
    Kumagai, Hiroshi
    Abe, Yusuke
    JOURNAL OF ARTIFICIAL ORGANS, 2014, 17 (01) : 9 - 15
  • [37] Computational fluid dynamics analysis of salivary flow and its effect on sialolithogenesis
    Zhu, P.
    Lin, Y.
    Lin, H.
    Xu, Y.
    Zheng, Q. Y.
    Han, Y.
    ORAL DISEASES, 2014, 20 (06) : 624 - 630
  • [38] Computational Fluid Dynamics Model for Sensitivity Analysis and Design of Flow Conditioners
    Askari, V
    Nicolas, D.
    Edralin, M.
    Jang, C.
    SIMULTECH: PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON SIMULATION AND MODELING METHODOLOGIES, TECHNOLOGIES AND APPLICATIONS, 2019, 2019, : 129 - 140
  • [39] Computational fluid dynamics analysis of the pump parameters in the helical flow pump
    Kyohei Hosoda
    Kohei Ishii
    Takashi Isoyama
    Itsuro Saito
    Yusuke Inoue
    Kouki Ariyoshi
    Toshiya Ono
    Hidemoto Nakagawa
    Kou Imachi
    Hiroshi Kumagai
    Yusuke Abe
    Journal of Artificial Organs, 2014, 17 : 9 - 15
  • [40] Transmitral flow analysis by means of Computational Fluid Dynamics on unstructured grids
    Capozzolo, C
    Denaro, FM
    Sarghini, F
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 593 - 600