A comparison of HDR near source dosimetry using a treatment planning system, Monte Carlo simulation; and radiochromic film

被引:3
|
作者
Amoush, Ahmad [1 ]
Luckstead, Marcus [1 ]
Lamba, Michael [1 ]
Elson, Howard [1 ]
Kassing, William [1 ]
机构
[1] Univ Cincinnati, Coll Med, Dept Radiat Oncol, Cincinnati, OH 45267 USA
关键词
HDR; TG-43U1; Radiochromic film dosimetry; MC simulation; BRACHYTHERAPY SOURCES; IR-192; RECOMMENDATIONS; BETA;
D O I
10.1016/j.meddos.2012.10.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study aimed to investigate the high-dose rate Iridium-192 brachytherapy, including near source dosimetry, of a catheter-based applicator from 0.5 mm to 1 cm along the transverse axis. Radiochromic film and Monte Carlo (MC) simulation were used to generate absolute dose for the catheter-based applicator. Results from radiochromic film and MC simulation were compared directly to the treatment planning system (TPS) based on the American Association of Physicists in Medicine Updated Task Group 43 (TG-43U1) dose calculation formalism. The difference between dose measured using radiochromic film along the transverse plane at 0.5 mm from the surface and the predicted dose by the TPS was 24% +/- 13%. The dose difference between the MC simulation along the transverse plane at 0.5 mm from the surface and the predicted dose by the TPS was 22.1% +/- 3%. For distances from 1.5 mm to 1 cm from the surface, radiochromic film and MC simulation agreed with TPS within an uncertainty of 3%. The TPS under-predicts the dose at the surface of the applicator, i.e., 0.5 mm from the catheter surface, as compared to the measured and MC simulation predicted dose. MC simulation results demonstrated that 15% of this error is due to neglecting the beta particles and discrete electrons emanating from the sources and not considered by the TPS, and 7% of the difference was due to the photon alone, potentially due to the differences in MC dose modeling, photon spectrum, scoring techniques, and effect of the presence of the catheter and the air gap. Beyond 1 mm from the surface, the TPS dose algorithm agrees with the experimental and MC data within 3%. (C) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:160 / 164
页数:5
相关论文
共 50 条
  • [1] A Comparison of HDR Near Source Dosimetry Using a Treatment Planning System, Monte Carlo Simulation, and Radiochromic Film
    Amoush, A.
    Luckstead, M.
    Lamba, M.
    Elson, H.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Dosimetry of Strontium eye applicator: Comparison of Monte Carlo calculations and radiochromic film measurements
    Laoues, M.
    Khelifi, R.
    Moussa, A. S.
    [J]. 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [3] Implementation of a Novel HDR Source Tracking Model for Source Quality Assurance Using Radiochromic Film Dosimetry
    Aldelaijan, S.
    Devic, S.
    Bekerat, H.
    Papaconstadopoulos, P.
    Schneider, J.
    Seuntjens, J.
    Cormack, R.
    Buzurovic, I.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E366 - E366
  • [4] Radiochromic film dosimetry of HDR 192Ir source radiation fields
    Aldelaijan, Saad
    Mohammed, Huriyyah
    Tomic, Nada
    Liang, Li-Heng
    DeBlois, Francois
    Sarfehnia, Arman
    Abdel-Rahman, Wamied
    Seuntjens, Jan
    Devic, Slobodan
    [J]. MEDICAL PHYSICS, 2011, 38 (11) : 6074 - 6083
  • [5] Dosimetry of MammoSite® applicator: Comparison between Monte Carlo simulation, measurements, and treatment planning calculation
    Oshaghi, Mina
    Sadeghi, Mahdi
    Mahdavi, Seied Rabi
    Shirazi, Alireza
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2013, 9 (02) : 224 - 229
  • [6] Monte-Carlo based prediction of radiochromic film response for hadrontherapy dosimetry
    Frisson, T.
    Zahra, N.
    Lautesse, P.
    Sarrut, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 606 (03): : 749 - 754
  • [7] Near-catheter dosimetry of a HDR brachytherapy source using Gafchromic film
    David Odgers
    Mamoon Haque
    [J]. Australasian Physical & Engineering Sciences in Medicine, 2013, 36 : 159 - 166
  • [8] Near-catheter dosimetry of a HDR brachytherapy source using Gafchromic film
    Odgers, David
    Haque, Mamoon
    [J]. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (02) : 159 - 166
  • [9] Dosimetric Accuracy of an HDR Brachytherapy Treatment Planning System for Different Irradiation Lengths with Monte Carlo Simulation
    Acun Bucht, Hediye
    Bozkurt, Ahmet
    Kemikler, Gonul
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2019, 34 (01): : 36 - 44
  • [10] Experimental verification of lung dose with radiochromic film: comparison with Monte Carlo simulations and commercially available treatment planning systems
    Paelinck, L
    Reynaert, N
    Thierens, H
    De Neve, W
    De Wagter, C
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (09): : 2055 - 2069