Modeling and experiments on energy loss in horizontal connecting pipe of vertical ground source heat pump system

被引:31
|
作者
Luo, Jin [1 ]
Rohn, Joachim [1 ]
Bayer, Manfred [2 ]
Priess, Anna [1 ]
机构
[1] Univ Erlangen Nurnberg, GeoZentrum Nordbayern, D-91054 Bayern, Germany
[2] LGA Bautech GmbH, TUV Rheinland, D-90431 Nurnberg, Germany
关键词
Ground source heat pump system; Horizontal connecting pipe; Pipe burial depth; Heat carrier fluid; Pipe insulation; Energy loss;
D O I
10.1016/j.applthermaleng.2013.07.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
In a vertical ground source heat pump (GSHP) system, horizontal pipe is the connection between borehole heat exchanger (BHE) and building. In current estimation of system performance, the energy loss of fluid circulating through a horizontal connecting pipe is often ignored. However, such energy loss can seriously reduce the thermal efficiency of GSHP systems in cold regions. This paper investigates the impacts of pipe burial depth and pipe insulation on energy loss of horizontal connecting pipes of a GSHP system in Nuremberg, Germany. The fluid circulation in a horizontal connecting pipe is investigated via experimental measurement and numerical simulation. Both the on-site data and numerical results suggest that the fluid temperature is substantially influenced by pipe burial depth as well as insulation. The numerical modeling shows that the daily energy loss can vary in magnitudes, as determined by pipe burial depth. On the other hand, up to 50% energy loss can be avoided by adopting a 25 mm thick insulation. These findings suggest that the both pipe burial depth and pipe insulation are important factors to be seriously considered for energy saving in the design and implementation of GSHP systems. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:55 / 64
页数:10
相关论文
共 50 条
  • [22] Energy and exergy analysis of a combined ground source heat pump system
    Ozturk, Murat
    APPLIED THERMAL ENGINEERING, 2014, 73 (01) : 362 - 370
  • [23] Energy and exergy analysis of a ground source (geothermal) heat pump system
    Hepbasli, A
    Akdemir, O
    ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (05) : 737 - 753
  • [24] Energy and exergy analysis of a combined ground source heat pump system
    Ozturk, M. (muratozturk@sdu.edu.tr), 1600, Elsevier Ltd (73):
  • [25] Evaluation of stainless steel pipe performance as a ground heat exchanger in ground-source heat-pump system
    Yoon, Seok
    Lee, Seung-Rae
    Kim, Min-Jun
    Kim, Woo-Jin
    Kim, Geon-Young
    Kim, Kyungsu
    ENERGY, 2016, 113 : 328 - 337
  • [26] Study on Optimization Design of Ground Source Heat Pump System with Horizontal Spiral Pipes
    Su, Shunyu
    Wu, Rui
    2020 4TH INTERNATIONAL WORKSHOP ON RENEWABLE ENERGY AND DEVELOPMENT (IWRED 2020), 2020, 510
  • [27] Experimental thermal performance evaluation of a horizontal ground-source heat pump system
    Inalli, M
    Esen, H
    APPLIED THERMAL ENGINEERING, 2004, 24 (14-15) : 2219 - 2232
  • [28] Energy and exergy analysis of a ground-coupled heat pump system with two horizontal ground heat exchangers
    Esen, Hikmet
    Inalli, Mustafa
    Esen, Mehmet
    Pihtili, Kazim
    BUILDING AND ENVIRONMENT, 2007, 42 (10) : 3606 - 3615
  • [29] Experimental Study Of Heating-cooling Combined Ground Source Heat Pump System with Horizontal Ground Heat Exchanger
    Hu, Ying-Ning
    Peng, Ban-Jun
    Hu, Shan-Shan
    Lin, Jun
    SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 398 - 404
  • [30] Alternative refrigerants for the heat pump of a ground source heat pump system
    Sagia, Zoi
    Rakopoulos, Constantinos