Energy and exergy analysis of a combined ground source heat pump system

被引:36
|
作者
Ozturk, Murat [1 ]
机构
[1] Suleyman Demirel Univ, Fac Technol, Dept Mech Engn, TR-32260 Isparta, Turkey
关键词
Combined GSHP; Thermodynamic analysis; PV/T collector-evaporator; PERFORMANCE ASSESSMENT; GASIFICATION; COALS;
D O I
10.1016/j.applthermaleng.2014.08.016
中图分类号
O414.1 [热力学];
学科分类号
摘要
The main focus of this paper is to analyze the energy and exergy efficiencies of a combined ground source heat pump (GSHP) system whose evaporator component works as a photovoltaic-thermal (PV/T) collector, and to determine the locations of the inefficiencies. This combined GSHP system consists of a heat pump cycle, a radiator thermal cycle, a ground heat exchanger cycle and a cooling tower cycle. The performance effects of the cooling tower have been examined, and optimal operation parameters have been selected to maximize the system efficiency. Exergy destruction rates, exergy efficiencies, exergy loss ratios of the system components and the whole system, as well as the energetic and exergetic coefficient of performance (COP) for the heat pump cycle have been evaluated for investigation of the potential improvement of the system components. From the results, exergy efficiency, COPsys and COPex of the system have been found as 74.72%, 2.895% and 039%, respectively. Additionally, parametric studies, including the thermodynamic performance of the system and its components, have been conducted by the change in some operating conditions, as variation of the ambient temperature changes from 0 degrees C to 30 degrees C, and the intensity of solar radiation that comes on the PV/T evaporator surface ranges from 400 W/m(2) to 900 W/m(2). (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:362 / 370
页数:9
相关论文
共 50 条
  • [1] Energy and exergy analysis of a ground source (geothermal) heat pump system
    Hepbasli, A
    Akdemir, O
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (05) : 737 - 753
  • [2] Energy and exergy analysis of a ground source heat pump system with a slinky ground heat exchanger supported by nanofluid
    Kapicioglu, Abdullah
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2022, 147 (02) : 1455 - 1468
  • [3] Energy and exergy analysis of a ground source heat pump system with a slinky ground heat exchanger supported by nanofluid
    Abdullah Kapicioglu
    [J]. Journal of Thermal Analysis and Calorimetry, 2022, 147 : 1455 - 1468
  • [4] Energy and Exergy Analysis of a Ground Water Heat Pump System
    Lei Fei
    Hu Pingfang
    [J]. INTERNATIONAL CONFERENCE ON APPLIED PHYSICS AND INDUSTRIAL ENGINEERING 2012, PT A, 2012, 24 : 169 - 175
  • [5] Exergy analysis of a hybrid ground-source heat pump system
    Menberg, Kathrin
    Heo, Yeonsook
    Choi, Wonjun
    Ooka, Ryozo
    Choudhary, Ruchi
    Shukuya, Masanori
    [J]. APPLIED ENERGY, 2017, 204 : 31 - 46
  • [6] Energy and exergy analysis of surface water source heat pump system
    Kocakulak, Serkan
    Yilmaz, Sezayi
    Ergun, Alper
    [J]. JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2023, 26 (03): : 1049 - 1058
  • [7] Experimental exergy assessment of ground source heat pump system
    Ahmad, Saif Nawaz
    Prakash, Om
    [J]. ADVANCES IN ENERGY RESEARCH, 2019, 6 (02): : 161 - 172
  • [8] Comparison of energy and exergy analysis of fossil plant, ground and air source heat pump building heating system
    Lohani, S. P.
    Schmidt, D.
    [J]. RENEWABLE ENERGY, 2010, 35 (06) : 1275 - 1282
  • [9] EXERGY ANALYSIS OF A DX GROUND-SOURCE HEAT PUMP SYSTEM IN XIANGTAN, CHINA
    Yang, Wei
    Zhang, Guoqiang
    Zhou, Jin
    Zhang, Peng
    [J]. FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 2187 - 2194
  • [10] Exergy Analysis of a Ground Source Heat Pump System Under Cooling and Heating Conditions
    Zhao, Lei
    Yuan, Chen
    [J]. PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 799 - 806