Application of Al2O3:C+fibre dosimeters for 290 MeV/n carbon therapeutic beam dosimetry

被引:12
|
作者
Nascimento, L. F. [1 ,2 ,4 ]
Vanhavere, F. [2 ]
Kodaira, S. [5 ]
Kitamura, H. [5 ]
Verellen, D. [4 ]
De Deene, Y. [1 ,3 ]
机构
[1] Univ Ghent, Dept Radiotherapy & Expt Canc Res, B-9000 Ghent, Belgium
[2] CEN SCK, Belgian Nucl Res Ctr, B-2400 Mol, Belgium
[3] Univ Sydney, Sch Phys, Inst Med Phys, Sydney, NSW 2006, Australia
[4] Univ Brussels VUB, UZ Brussel, Radiotherapie, Grp Med Fys, Brussels, Belgium
[5] Natl Inst Radiol Sci, Radiat Measurement Res Sect, Chiba 260, Japan
关键词
OPTICALLY STIMULATED LUMINESCENCE; PROTON-BEAMS; RADIOLUMINESCENCE; PHOTON; RADIOTHERAPY; IRRADIATION; DETECTOR; MODEL;
D O I
10.1016/j.radphyschem.2015.06.001
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The capability of radioluminescence (RL) dosimeters composed of carbon-doped aluminium oxide (Al2O3:C) detectors+optical fibre has been verified for absorbed dose-rate measurements during carbon radiotherapy. The RL signals from two separate Al2O3:C detectors (single crystal 'CG' and droplet 'P1') have been systematically measured and compared along the Bragg-curve and Spread-Out Bragg-Peak of 290 MeV/n carbon beams in the water. The absorbed dose response was assessed for the range of 0.5-10 Gy. For doses up to 6 Gy, we observed a linear response for both types of detectors, while for higher doses CG presented a more prominent supraliearity than P1. The RL response for low-LET protons in the entrance from the curve was found to closely resemble that observed for a clinical 6 MV X-ray beam, while it was found that P1 has a better agreement with the reference data from standard ionization chamber than CG. We observed a significant decrease in luminescence efficiency with LET in the Bragg peak region. The Al2O3:C RI, luminescence efficiency differs from Al2O3:C OSL results, which implies that the signal can be corrected for LET dependency to match the correct SOBP and Bragg Peak. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:75 / 80
页数:6
相关论文
共 50 条
  • [1] Radioluminescence of Ge-doped silica optical fibre and Al2O3:C dosimeters
    Rahman, A. K. M. Mizanur
    Begum, Mahfuza
    Begum, Mahbuba
    Zubair, H. T.
    Abdul-Rashid, H. A.
    Yusoff, Z.
    Bradley, D. A.
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 270 : 72 - 78
  • [2] Fibre remote optoelectronic gamma dosimetry based on optically stimulated luminescence of Al2O3:C
    Ranchoux, G
    Magne, S
    Bouvet, JP
    Ferdinand, F
    RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 255 - 260
  • [3] Fibre remote optoelectronic gamma dosimetry based on optically stimulated luminescence of Al2O3:C
    Ranchoux, G
    Magne, S
    Bouvet, JP
    Ferdinand, P
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 255 - 260
  • [4] Thin sintered Al2O3 pellets as thermoluminescent dosimeters for the therapeutic dose range
    Rocha, FDG
    Oliveira, ML
    Caldas, LVE
    APPLIED RADIATION AND ISOTOPES, 2003, 58 (06) : 719 - 722
  • [5] Real-time two dimensional dosimetry using Al2O3:C and Al2O3:C,Mg films
    de F. Nascimento, Luana
    Goossens, Jo
    Leblans, Paul
    Sterckx, Paul
    Vanhavere, Filip
    Struelens, Lara
    Akselrod, Mark
    Verellen, Dirk
    Sensors and Actuators, A: Physical, 2021, 318
  • [6] Real-time two dimensional dosimetry using Al2O3 :C and Al2O3 :C,Mg films
    Nascimento, Luana de F.
    Goossens, Jo
    Leblans, Paul
    Sterckx, Paul
    Vanhavere, Filip
    Struelens, Lara
    Akselrod, Mark
    Verellen, Dirk
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 318
  • [7] High-precision dosimetry for radiotherapy using the optically stimulated luminescence technique and thin Al2O3:C dosimeters
    Yukihara, EG
    Yoshimura, EM
    Lindstrom, TD
    Ahmad, S
    Taylor, KK
    Mardirossian, G
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (23): : 5619 - 5628
  • [8] Al2O3:C optically stimulated luminescence dosimeters (OSLDs) for ultra-high dose rate proton dosimetry
    Christensen, Jeppe Brage
    Togno, Michele
    Nesteruk, Konrad Pawel
    Psoroulas, Serena
    Meer, David
    Weber, Damien Charles
    Lomax, Tony
    Yukihara, Eduardo G.
    Safai, Sairos
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (08):
  • [9] Influence of point defects on the thermoluminescence of α-Al2O3:: Application to dosimetry
    Papin, E
    Grosseau, P
    Guilhot, B
    Benabdesselam, M
    Iacconi, P
    RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) : 91 - 94
  • [10] Characterization of nanoporous Al2O3:C for thermoluminescent radiation dosimetry
    de Barros, V. S. M.
    Khoury, H. J.
    Azevedo, W. M.
    da Silva, E. F., Jr.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 180 - 182