Radioluminescence of Ge-doped silica optical fibre and Al2O3:C dosimeters

被引:16
|
作者
Rahman, A. K. M. Mizanur [1 ,3 ]
Begum, Mahfuza [2 ,3 ]
Begum, Mahbuba [1 ]
Zubair, H. T. [3 ]
Abdul-Rashid, H. A. [3 ]
Yusoff, Z. [3 ]
Bradley, D. A. [4 ,5 ]
机构
[1] Bangladesh Atom Energy Commiss, Hlth Phys Div, Atom Energy Ctr, 4 Kazi Nazrul Islam Ave, Dhaka 1000, Bangladesh
[2] Bangladesh Atom Energy Commiss, Hlth Phys & Radioact Waste Management Unit, Inst Nucl Sci & Technol, Atom Energy Res Estab, Dhaka, Bangladesh
[3] Multimedia Univ, Fibre Opt Res Ctr, Fac Engn, Jalan Multimedia, Cyberjaya 63100, Malaysia
[4] Univ Surrey, Dept Phys, Guildford GU2 7XH, Surrey, England
[5] Sunway Univ, Inst Hlth Care Dev, Pj 46150, Malaysia
关键词
Radioluminescence; Ge-doped optical fibre; NanoDots Al2O3C; Afterglow; REAL-TIME DOSIMETRY; MEDICAL DOSIMETRY; RADIATION-DOSIMETRY; LUMINESCENCE; RADIOTHERAPY; THERAPY; SIGNAL;
D O I
10.1016/j.sna.2017.12.032
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Using an electron accelerator producing a 6 MV X-ray photon beam several experimentally observed excitation phenomena that are associated with radioluminescence (RL) have been investigated, the signal originating from a Ge-doped silica optical fibre and commercial nanoDot Al2O3:C dosimeters. Using PMMA optical communication fibres the RL signals have been guided from the beam-delivery room out to the readout instrumentation that has been located beyond the concrete maze providing effective radiation shield. Ge-doped silica fibre memory effects and afterglow (phosphorescence) were compared with that of the commercial Al2O3:C dosimeter. Immediately following RL, observation was made of the decay curves of the afterglow signal of Al2O3:C. Conversely, there was little practically observable afterglow for the Ge-doped fibre used for the majority of present investigations (the dopant concentration of this being 3.6 wt %). Among three different concentration of Ge-doped fibres that were subsequently investigated in a follow-up study, the intensity of afterglow was found to be greatest for the more highly doped concentration (7.0 wt % Ge), with progressive reduction of the effect for the Ge 4.7 wt % and Ge 3.6 wt % fibres. These observations can be compared against the much more marked RL memory effect observed using the Al2O3:C chips. Current results point to the Ge-doped silica optical fibre being a highly promising candidate for real-time RL dosimetry and sensing. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:72 / 78
页数:7
相关论文
共 50 条
  • [1] Influence of dose history on thermoluminescence response of Ge-doped silica optical fibre dosimeters
    Moradi, F.
    Mandiraji, G. A.
    Dermosesian, E.
    Khandaker, M. U.
    ung, N. M.
    Adikan, F. R. Mahamd
    Amin, Y. M.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 134 : 62 - 70
  • [2] Investigation of Ge-doped fibre detectors as audit dosimeters
    McEwen, Malcolm
    Issa, Fatma
    MEDICAL PHYSICS, 2024, 51 (08) : 5815 - 5815
  • [3] Ge-doped silica optical fibres as RL/OSL dosimeters for radiotherapy dosimetry
    Rahman, A. K. M. Mizanur
    Begum, Mahfuza
    Zubair, H. T.
    Abdul-Rashid, H. A.
    Yusoff, Z.
    Ung, N. M.
    Bradley, D. A.
    SENSORS AND ACTUATORS A-PHYSICAL, 2017, 264 : 30 - 39
  • [4] Influence of the stem effect on radioluminescence signals from optical fibre Al2O3:C dosemeters
    Marckmann, Carl Johan
    Aznar, Marianne C.
    Andersen, Claus E.
    Botter-Jensen, Lars
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 363 - 367
  • [5] Ge-doped silica optical fibre for Time Resolved Radiation Dosimetry
    Basaif, A.
    Oresegun, Adebiyi
    Tarif, Zubair H.
    Zin, Hafiz
    Choo, K. Y.
    Ibrahim, S. A.
    Abdul-Rashid, H. A.
    Bradley, D. A.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 189
  • [6] Investigating Radionuclide Source Shielding Performance Using Ge-doped Optical Fibre Thermoluminescence Dosimeters
    Issa, Fatma
    Hugtenburg, R. P.
    Bradley, D. A.
    Nisbet, A.
    IX LATIN AMERICAN SYMPOSIUM ON NUCLEAR PHYSICS AND APPLICATIONS, 2012, 1423
  • [7] Ge-doped silica fibre for proton beam dosimetry
    Hassan, M. F.
    Rahman, W. N. W. A.
    Tominaga, T.
    Geso, M.
    Akasaka, H.
    Bradley, D. A.
    Noor, N. M.
    RADIATION PHYSICS AND CHEMISTRY, 2019, 165
  • [8] Establishment of Ge-doped optical fibres as thermoluminescence dosimeters for brachytherapy
    Issa, Fatma
    Rahman, A. T. Abdul
    Hugtenburg, Richard P.
    Bradley, David A.
    Nisbet, Andrew
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1158 - 1161
  • [9] Radioluminescence of cylindrical and flat Ge-doped silica optical fibers for real-time dosimetry applications
    Oresegun, Adebiyi
    Tarif, Zubair H.
    Ghassan, Louay
    Zin, Hafiz
    Abdul-Rashid, Hairul Azhar
    Bradley, D. A.
    APPLIED RADIATION AND ISOTOPES, 2021, 176 (176)
  • [10] Small-field output ratio determination using 6 mol% Ge-doped silica fibre dosimeters
    Lam, S. E.
    Noor, N. Mohd
    Bradley, D. A.
    Mahmud, R.
    Pawanchek, M.
    Rashid, H. A. Abdul
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (06)