Al2O3:C optically stimulated luminescence dosimeters (OSLDs) for ultra-high dose rate proton dosimetry

被引:44
|
作者
Christensen, Jeppe Brage [1 ]
Togno, Michele [2 ]
Nesteruk, Konrad Pawel [2 ]
Psoroulas, Serena [2 ]
Meer, David [2 ]
Weber, Damien Charles [2 ,3 ,4 ]
Lomax, Tony [2 ,5 ]
Yukihara, Eduardo G. [1 ]
Safai, Sairos [2 ]
机构
[1] Paul Scherrer Inst, Dept Radiat Safety & Secur, Villigen, Switzerland
[2] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
[3] Univ Hosp Zurich, Dept Radiat Oncol, Zurich, Switzerland
[4] Univ Hosp Bern, Dept Radiat Oncol, Bern, Switzerland
[5] Swiss Fed Inst Technol, Dept Phys, Zurich, Switzerland
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 08期
基金
瑞士国家科学基金会;
关键词
FLASH; proton dosimetry; optically stimulated luminescence; Al2O3; C; ultra-high dose rate; RATE DEPENDENCE;
D O I
10.1088/1361-6560/abe554
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The response of Al2O3:C optically stimulated luminescence detectors (OSLDs) was investigated in a 250 MeV pencil proton beam. The OSLD response was mapped for a wide range of average dose rates up to 9000 Gy s(-1), corresponding to a similar to 150 kGy s(-1) instantaneous dose rate in each pulse. Two setups for ultra-high dose rate (FLASH) experiments are presented, which enable OSLDs or biological samples to be irradiated in either water-filled vials or cylinders. The OSLDs were found to be dose rate independent for all dose rates, with an average deviation <1% relative to the nominal dose for average dose rates of (1-1000) Gy s(-1) when irradiated in the two setups. A third setup for irradiations in a 9000 Gy s(-1) pencil beam is presented, where OSLDs are distributed in a 3 x 4 grid. Calculations of the signal averaging of the beam over the OSLDs were in agreement with the measured response at 9000 Gy s(-1). Furthermore, a new method was presented to extract the beam spot size of narrow pencil beams, which is in agreement within a standard deviation with results derived from radiochromic films. The Al2O3:C OSLDs were found applicable to support radiobiological experiments in proton beams at ultra-high dose rates.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] High-precision dosimetry for radiotherapy using the optically stimulated luminescence technique and thin Al2O3:C dosimeters
    Yukihara, EG
    Yoshimura, EM
    Lindstrom, TD
    Ahmad, S
    Taylor, KK
    Mardirossian, G
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (23): : 5619 - 5628
  • [2] Radiation dosimetry using pulsed optically stimulated luminescence of Al2O3:C
    McKeever, SWS
    Akselrod, MS
    RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) : 317 - 320
  • [3] Recent advances in dosimetry using the optically stimulated luminescence of Al2O3:C
    McKeever, SWS
    Blair, MW
    Bulur, E
    Gaza, R
    Gaza, R
    Kalchgruber, R
    Klein, DM
    Yukihara, EG
    RADIATION PROTECTION DOSIMETRY, 2004, 109 (04) : 269 - 276
  • [4] Effect of high-dose irradiation on the optically stimulated luminescence of Al2O3:C
    Yukihara, EG
    Whitley, VH
    McKeever, SWS
    Akselrod, AE
    Akselrod, MS
    RADIATION MEASUREMENTS, 2004, 38 (03) : 317 - 330
  • [5] Dosimetry of ultra-high dose rate electron beams using thermoluminescence and optically stimulated luminescence detectors
    Motta, S.
    Dal Bello, R.
    Christensen, J. B.
    Bossin, L.
    Yukihara, E. G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (03):
  • [6] Evaluation of Al2O3 : C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy
    Yukihara, E. G.
    Mardirossian, G.
    Mirzasadeghi, M.
    Guduru, S.
    Ahmad, S.
    MEDICAL PHYSICS, 2008, 35 (01) : 260 - 269
  • [7] Performance of Al2O3:C optically stimulated luminescence dosimeters for clinical radiation therapy applications
    B. Hu
    Y. Wang
    W. Zealey
    Australasian Physical & Engineering Sciences in Medicine, 2009, 32 : 226 - 232
  • [8] Optically stimulated Al2O3:C luminescence dosimeters for teletherapy: Hp(10) performance evaluation
    Hashim, S.
    Musa, Y.
    Ghoshal, S. K.
    Ahmad, N. E.
    Hashim, I. H.
    Yusop, M.
    Bradley, D. A.
    Kadir, A. B. A.
    APPLIED RADIATION AND ISOTOPES, 2018, 135 : 7 - 11
  • [9] Performance of Al2O3:C optically stimulated luminescence dosimeters for clinical radiation therapy applications
    Hu, B.
    Wang, Y.
    Zealey, W.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (04) : 226 - 232
  • [10] Modeling Influence Factors of Al2O3:C Optically Stimulated Luminescence Detectors (OSLDs) Exposed to Radiotherapy Beams
    Sawakuchi, G. O.
    Omotayo, A.
    Yukihara, E. G.
    MEDICAL PHYSICS, 2012, 39 (06) : 3716 - 3716