Reliability and precision of in vivo scapular kinematic measurements using an electromagnetic tracking device

被引:15
|
作者
Myers, Joseph [1 ]
Jolly, John [1 ]
Nagai, Takashi [1 ]
Lephart, Scoff [1 ]
机构
[1] Univ Pittsburgh, Neuromuscular Res Lab, Pittsburgh, PA 15203 USA
关键词
shoulder; biomechanics; motion analysis;
D O I
10.1123/jsr.15.2.125
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: In vivo scapular kinematics during humeral movements are commonly assessed with electromagnetic tracking devices despite few published data related to reliability and precision of these measurements. Objective: To determine the intrasession reliability and precision of assessing scapular kinematics using an electromagnetic tracking device. Design: Scapular position and orientation were measured with an electromagnetic tracking device during humeral elevation/ depression in several planes. Intrasession reliability and precision were established by comparing 2 trials performed in succession. Setting: A human-movement research laboratory. Participants: 15 healthy individuals. Main Outcome Measures: Intrasession intraclass correlation coefficients and standard error of measurement of all scapular variables were established. Results: The mean intrasession reliability for all variables was ICC =.97 +/- .03. The mean intrasession precision was .99 degrees +/- .36 degrees. Conclusions: In vivo scapular kinematics can be measured with high reliability and precision during intrasession research designs.
引用
收藏
页码:125 / 143
页数:19
相关论文
共 50 条
  • [1] Reliability And Precision Of In-vivo Scapular Kinematic Measurements Using An Electromagnetic Tracking Device
    Myers, Joseph
    Jolly, John
    Nagai, Takashi
    Lephart, Scott
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S120 - S120
  • [2] Tracking filters using kinematic measurements
    Besada, Juan A.
    de Miguel, Gonzalo
    Soto, Andres
    Herrero, Jesus Garcia
    2007 PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INFORMATION FUSION, VOLS 1-4, 2007, : 1783 - +
  • [3] Validity and Reliability of the G-Cog Device for Kinematic Measurements
    Chiementin, X.
    Crequy, S.
    Bertucci, W.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2013, 34 (11) : 945 - 949
  • [4] Precision of 3D scapular kinematic measurements for analytic arm movements and activities of daily living
    Roren, Alexandra
    Fayad, Fouad
    Roby-Brami, Agnes
    Revel, Michel
    Fermanian, Jacques
    Poiraudeau, Serge
    Robertson, Johanna
    Lefevre-Colau, Marie-Martine
    MANUAL THERAPY, 2013, 18 (06) : 473 - 480
  • [5] Assessment of screw displacement axis accuracy and repeatability for joint kinematic description using an electromagnetic tracking device
    Duck, TR
    Ferreira, LM
    King, GJW
    Johnson, JA
    JOURNAL OF BIOMECHANICS, 2004, 37 (01) : 163 - 167
  • [6] Kinematic study of the mandible using an electromagnetic tracking device and custom dental appliance: Introducing a new technique
    Yoon, Hyun-Joong
    Zhao, Kristin D.
    Rebellato, Joe
    An, Kai-Nan
    Keller, Eugene E.
    JOURNAL OF BIOMECHANICS, 2006, 39 (12) : 2325 - 2330
  • [7] Measurements of knee rotation-reliability of an external device in vivo
    Almquist, Per O.
    Ekdahl, Charlotte
    Isberg, Per-Erik
    Friden, Thomas
    BMC MUSCULOSKELETAL DISORDERS, 2011, 12
  • [8] Measurements of knee rotation-reliability of an external device in vivo
    Per O Almquist
    Charlotte Ekdahl
    Per-Erik Isberg
    Thomas Fridén
    BMC Musculoskeletal Disorders, 12
  • [9] Determining dual Euler angles of the ankle complex in vivo using "Flock of birds" electromagnetic tracking device
    Ying, N
    Kim, W
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (01): : 98 - 107
  • [10] Reliability and validity of first metatarsophalangeal joint orientation measured with an electromagnetic tracking device
    Umberger, BR
    Nawoczenski, DA
    Baumhauer, JF
    CLINICAL BIOMECHANICS, 1999, 14 (01) : 74 - 76