Reliability and precision of in vivo scapular kinematic measurements using an electromagnetic tracking device

被引:15
|
作者
Myers, Joseph [1 ]
Jolly, John [1 ]
Nagai, Takashi [1 ]
Lephart, Scoff [1 ]
机构
[1] Univ Pittsburgh, Neuromuscular Res Lab, Pittsburgh, PA 15203 USA
关键词
shoulder; biomechanics; motion analysis;
D O I
10.1123/jsr.15.2.125
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Context: In vivo scapular kinematics during humeral movements are commonly assessed with electromagnetic tracking devices despite few published data related to reliability and precision of these measurements. Objective: To determine the intrasession reliability and precision of assessing scapular kinematics using an electromagnetic tracking device. Design: Scapular position and orientation were measured with an electromagnetic tracking device during humeral elevation/ depression in several planes. Intrasession reliability and precision were established by comparing 2 trials performed in succession. Setting: A human-movement research laboratory. Participants: 15 healthy individuals. Main Outcome Measures: Intrasession intraclass correlation coefficients and standard error of measurement of all scapular variables were established. Results: The mean intrasession reliability for all variables was ICC =.97 +/- .03. The mean intrasession precision was .99 degrees +/- .36 degrees. Conclusions: In vivo scapular kinematics can be measured with high reliability and precision during intrasession research designs.
引用
收藏
页码:125 / 143
页数:19
相关论文
共 50 条
  • [41] Reliability of left ventricular volumes and function measurements using three-dimensional speckle tracking echocardiography
    Kleijn, Sebastiaan A.
    Aly, Mohamed F. A.
    Terwee, Caroline B.
    van Rossum, Albert C.
    Kamp, Otto
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (02) : 159 - 168
  • [42] High precision, high sensitivity distributed displacement and temperature measurements using OFDR-based phase tracking
    Gifford, Dawn K.
    Froggatt, Mark E.
    Kreger, Stephen T.
    21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753
  • [43] The reliability and validity of three dimensional ultrasound volumetric measurements using an in vitro balloon and in vivo uterine model
    Farrell, T
    Leslie, JR
    Chien, PFW
    Agustsson, P
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2001, 108 (06): : 573 - 582
  • [44] In vivo measurements of patellar tracking and finite helical axis using a static magnetic resonance based methodology
    Yao, Jie
    Yang, Bin
    Niu, Wenxin
    Zhou, Jianwei
    Wang, Yuxing
    Gong, He
    Ma, Huasong
    Tan, Rong
    Fan, Yubo
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (12) : 1611 - 1617
  • [45] Validation of in vivo toenail measurements of manganese and mercury using a portable X-ray fluorescence device
    Aaron J. Specht
    Xinxin Zhang
    Anna Young
    Vy T. Nguyen
    David C. Christiani
    Diana M. Ceballos
    Joseph G. Allen
    Jennifer Weuve
    Linda H. Nie
    Marc G. Weisskopf
    Journal of Exposure Science & Environmental Epidemiology, 2022, 32 : 427 - 433
  • [46] Validation of in vivo toenail measurements of manganese and mercury using a portable X-ray fluorescence device
    Specht, Aaron J.
    Zhang, Xinxin
    Young, Anna
    Nguyen, Vy T.
    Christiani, David C.
    Ceballos, Diana M.
    Allen, Joseph G.
    Weuve, Jennifer
    Nie, Linda H.
    Weisskopf, Marc G.
    JOURNAL OF EXPOSURE SCIENCE AND ENVIRONMENTAL EPIDEMIOLOGY, 2022, 32 (03) : 427 - 433
  • [47] Electrical impedance measurements on teeth using the ECM-device -: a comparative in vivo and in vitro pilot study
    Tranæus, S
    Ollmar, S
    Lussi, A
    Angmar-Månsson, B
    JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1247 - 1247
  • [48] Design and evaluation of a computed tomography (CT)-compatible needle insertion device using an electromagnetic tracking system and CT images
    Navid Shahriari
    Edsko Hekman
    Matthijs Oudkerk
    Sarthak Misra
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 1845 - 1852
  • [49] Design and evaluation of a computed tomography (CT)-compatible needle insertion device using an electromagnetic tracking system and CT images
    Shahriari, Navid
    Hekman, Edsko
    Oudkerk, Matthijs
    Misra, Sarthak
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (11) : 1845 - 1852
  • [50] Real-Time Catheter Tracking for HDR Prostate Implant Using an Electromagnetic 3D Guidance Device
    Zhou, J.
    Sebastian, E.
    Ghilezan, M.
    Martinez, A.
    Yan, D.
    MEDICAL PHYSICS, 2011, 38 (06)