Paediatric x-ray radiation dose reduction and image quality analysis

被引:23
|
作者
Martin, L. [1 ]
Ruddlesden, R. [1 ]
Makepeace, C. [1 ]
Robinson, L. [1 ]
Mistry, T. [1 ]
Starritt, H. [1 ]
机构
[1] Royal United Hosp, Bath BA1 3NG, Avon, England
关键词
OPTIMIZATION; RADIOGRAPHY; EXPOSURE; CANCER;
D O I
10.1088/0952-4746/33/3/621
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Collaboration of multiple staff groups has resulted in significant reduction in the risk of radiation-induced cancer from radiographic x-ray exposure during childhood. In this study at an acute NHS hospital trust, a preliminary audit identified initial exposure factors. These were compared with European and UK guidance, leading to the introduction of new factors that were in compliance with European guidance on x-ray tube potentials. Image quality was assessed using standard anatomical criteria scoring, and visual grading characteristics analysis assessed the impact on image quality of changes in exposure factors. This analysis determined the acceptability of gradual radiation dose reduction below the European and UK guidance levels. Chest and pelvis exposures were optimised, achieving dose reduction for each age group, with 7%-55% decrease in critical organ dose. Clinicians confirmed diagnostic image quality throughout the iterative process. Analysis of images acquired with preliminary and final exposure factors indicated an average visual grading analysis result of 0.5, demonstrating equivalent image quality. The optimisation process and final radiation doses are reported for Carestream computed radiography to aid other hospitals in minimising radiation risks to children.
引用
收藏
页码:621 / 633
页数:13
相关论文
共 50 条
  • [11] Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality
    Geryes, Bouchra Habib
    Calmon, Raphael
    Khraiche, Diala
    Boddaert, Nathalie
    Bonnet, Damien
    Raimondi, Francesca
    [J]. EUROPEAN RADIOLOGY, 2016, 26 (07) : 2030 - 2038
  • [12] Including students in medical imaging research: optimization of image quality and x-ray radiation dose
    Aandahl, I. J.
    Sanderud, A.
    [J]. ACTA RADIOLOGICA, 2017, 58 : 23 - 23
  • [13] DOSE AND IMAGE QUALITY CALCULATIONS FOR CHEST X-RAY EXAMINATIONS
    KOBLINGE.L
    ZARAND, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (05): : 712 - &
  • [14] Dose reduction in a paediatric X-ray department following optimization of radiographic technique
    Mooney, R
    Thomas, PS
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (848): : 852 - 860
  • [15] Effective dose and breast dose reduction in paediatric scoliosis X-ray radiography by an optimal positioning
    Ben-Shlomo, Avi
    Bartal, Gabriel
    Shabat, Shay
    Mosseri, Morris
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 156 (01) : 30 - 36
  • [16] NOISE REDUCTION IN LOW-DOSE X-RAY FLUOROSCOPY FOR IMAGE-GUIDED RADIATION THERAPY
    Jing Wang
    Lei Zhu
    Lei Xing
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02): : 637 - 643
  • [17] Reduction of scattered radiation dose by X-ray shielding during mammography
    Koo, Bon-Yeoul
    Lee, Kwang-Sung
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 177
  • [18] A cross-sectional study of the radiation dose and image quality of X-ray equipment used in IVR
    Inaba, Yohei
    Chida, Koichi
    Kobayashi, Ryota
    Zuguchi, Masayuki
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 391 - 401
  • [19] Radiation dose and image quality for paediatric interventional cardiology
    Vano, E.
    Ubeda, C.
    Leyton, F.
    Miranda, P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (15): : 4049 - 4062
  • [20] The impact of X-ray scatter correction software on abdomen radiography in terms of image quality and radiation dose
    Sayed, M.
    Knapp, K. M.
    Fulford, J.
    Heales, C.
    Alqahtani, S. J.
    [J]. RADIOGRAPHY, 2024, 30 (04)