Effective dose and breast dose reduction in paediatric scoliosis X-ray radiography by an optimal positioning

被引:12
|
作者
Ben-Shlomo, Avi [1 ]
Bartal, Gabriel [2 ]
Shabat, Shay [3 ]
Mosseri, Morris [4 ]
机构
[1] Soreq NRC, Radiat Protect Domain, IL-81800 Yavne, Israel
[2] Meir Med Ctr, Dept Radiol, IL-44281 Kefar Sava, Israel
[3] Meir Med Ctr, Spinal Care Unit, Orthoped Surg Dept, IL-44281 Kefar Sava, Israel
[4] Meir Med Ctr, Cardiol Div, IL-44281 Kefar Sava, Israel
关键词
D O I
10.1093/rpd/nct038
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The purpose of this article is to recommend positioning to reduce the effective and breast-absorbed-doses in paediatric scoliosis radiography. Effective and breast-absorbed-doses were evaluated using Monte Carlo simulations. Head directed towards the anode (HTA) positioning rather than head directed towards the cathode (HTC) reduces the effective dose to 98 in anterior posterior (AP), 98 in left lateral (L LAT) and 96 in right lateral (R LAT) projections. HTC in posterior anterior (PA) projection contributes a smaller effective dose than HTA by 1 , but causes a breast-absorbed-dose excess (HTA/HTC breast dose ratios were 85 and 87 for 10- and 15-y- olds). With the preferential HTA positioning, R LAT projection reduced effective dose to 85 and 84 compared with L LAT, for 10 and 15 y olds. AP-HTA projection caused 183 and 181 larger effective doses than PA-HTA and breast-absorbed-dose excesses of 550 and 879 , for 10 and 15 y olds. When possible, use R LAT and PA projections to reduce effective dose; Of secondary importance, whenever possible, use HTA, with the exception that for 15 y olds, PA-HTC reduces the effective dose more than HTA (1 ) but causes a breast-absorbed-dose excess.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 50 条
  • [1] DOSE REDUCTION IN RADIOGRAPHY OF THE SPINE IN SCOLIOSIS
    ANDERSEN, PE
    ANDERSEN, PE
    VANDERKOOY, P
    [J]. ACTA RADIOLOGICA-DIAGNOSIS, 1982, 23 (03): : 251 - 253
  • [2] MINIMAL DOSE DIGITAL BREAST RADIOGRAPHY - OPTIMAL X-RAY-SPECTRUM
    BJORKHOLM, P
    SEGUIN, F
    ANNIS, M
    [J]. MEDICAL PHYSICS, 1985, 12 (04) : 544 - 544
  • [3] Paediatric x-ray radiation dose reduction and image quality analysis
    Martin, L.
    Ruddlesden, R.
    Makepeace, C.
    Robinson, L.
    Mistry, T.
    Starritt, H.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2013, 33 (03) : 621 - 633
  • [4] Dose reduction in a paediatric X-ray department following optimization of radiographic technique
    Mooney, R
    Thomas, PS
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (848): : 852 - 860
  • [5] Quantitative radiography of welds - dose rate, dose and contrast of x-ray equipment and films
    Holmstroem, Johan-Edvin
    [J]. Materialpruefung/Materials Testing, 1995, 37 (03): : 64 - 68
  • [6] THE INTEGRAL DOSE IN PANORAMIC INTRAORAL X-RAY TUBE RADIOGRAPHY
    HAYAMI, A
    FUJISHITA, M
    SUMIDA, A
    KANKE, M
    FUJIKI, T
    UEMURA, S
    FUCHIHATA, H
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1983, 56 (01): : 98 - 102
  • [7] A PROCEDURE FOR CALCULATION OF GONADAL X-RAY DOSE IN DIAGNOSTIC RADIOGRAPHY
    HELLER, MB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 173 - &
  • [8] A PROCEDURE FOR CALCULATION OF GONADAL X-RAY DOSE IN DIAGNOSTIC RADIOGRAPHY
    HELLER, MB
    TERDIMAN, JF
    PASTERNACK, BS
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1966, 39 (465): : 686 - +
  • [9] Patient effective dose evaluation for chest X-ray examination in three digital radiography centers
    Paydar, R.
    Takavar, A.
    Kardan, M. R.
    Babakhani, A.
    Deevband, M. R.
    Saber, S.
    [J]. IRANIAN JOURNAL OF RADIATION RESEARCH, 2012, 10 (3-4): : 139 - 143
  • [10] Effective dose for scoliosis patients undergoing full spine radiography
    Mogaadi, M.
    Ben Omrane, L.
    Hammou, A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2012, 149 (03) : 297 - 303