Automatic Mapping of CT Scan Locations on Computational Human Phantoms for Organ Dose Estimation

被引:5
|
作者
Lee, Choonsik [1 ,2 ]
Kuzmin, Gleb A. [1 ]
Bae, Jinyong [3 ]
Yao, Jianhua [4 ]
Mosher, Elizabeth [1 ]
Folio, Les R. [4 ]
机构
[1] NCI, Div Canc Epidemiol & Genet, NIH, Bethesda, MD 20892 USA
[2] NCI, Radiat Epidemiol Branch, DCEG, NIH, 9609 Med Ctr Dr, Rockville, MD 20850 USA
[3] Kansas City Univ Med & Biosci, Kansas City, KS USA
[4] NIH, Radiol & Imaging Sci Clin Ctr, Bldg 10, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
Computed tomograpy; Dosimetry; Scan location; Computational human phantoms; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; ADULT; PROGRAM;
D O I
10.1007/s10278-018-0119-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To develop an algorithm to automatically map CT scan locations of patients onto computational human phantoms to provide with patient-specific organ doses. We developed an algorithm that compares a two-dimensional skeletal mask generated from patient CTs with that of a whole body computational human phantom. The algorithm selected the scan locations showing the highest Dice Similarity Coefficient (DSC) calculated between the skeletal masks of a patient and a phantom. To test the performance of the algorithm, we randomly selected five sets of neck, chest, and abdominal CT images from the National Institutes of Health Clinical Center. We first automatically mapped scan locations of the CT images on a computational human phantom using our algorithm. We had several radiologists to manually map the same CT images on the phantom and compared the results with the automated mapping. Finally, organ doses for automated and manual mapping locations were calculated by an in-house CT dose calculator and compared to each other. The visual comparison showed excellent agreement between manual and automatic mapping locations for neck, chest, and abdomen-pelvis CTs. The difference in mapping locations averaged over the start and end in the five patients was less than 1 cm for all neck, chest, and AP scans: 0.9, 0.7, and 0.9 cm for neck, chest, and AP scans, respectively. Five cases out of ten in the neck scans show zero difference between the average manual and automatic mappings. Average of absolute dose differences between manual and automatic mappings was 2.3, 2.7, and 4.0% for neck, chest, and AP scans, respectively. The automatic mapping algorithm provided accurate scan locations and organ doses compared to manual mapping. The algorithm will be useful in cases requiring patient-specific organ dose for a large number of patients such as patient dose monitoring, clinical trials, and epidemiologic studies.
引用
收藏
页码:175 / 182
页数:8
相关论文
共 50 条
  • [1] Automatic Mapping of CT Scan Locations on Computational Human Phantoms for Organ Dose Estimation
    Choonsik Lee
    Gleb A. Kuzmin
    Jinyong Bae
    Jianhua Yao
    Elizabeth Mosher
    Les R. Folio
    Journal of Digital Imaging, 2019, 32 : 175 - 182
  • [2] Organ Dose Estimation in Body CT Examinations Using a Mathematical Model Based On Planar Scan Range Average Dose
    Faghihi, R.
    Sina, S.
    Masoudi, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E546 - E546
  • [3] Organ Dose Estimation for CT Localizer Images
    Hoye, J.
    Zhang, Y.
    Fu, W.
    Abadi, E.
    Ria, F.
    Kapadia, A.
    Segars, P.
    Samei, E.
    MEDICAL PHYSICS, 2017, 44 (06) : 3301 - 3301
  • [4] Comparison of organ dose and dose equivalent for human phantoms of CAM vs. MAX
    Kim, Myung-Hee Y.
    Qualls, Garry D.
    Slaba, Tony C.
    Cucinotta, Francis A.
    ADVANCES IN SPACE RESEARCH, 2010, 45 (07) : 850 - 857
  • [5] Construction of personalized computational phantoms of pregnant patients for assessment of CT radiation dose
    Xie, Tianwu
    Poletti, Pierre-Alexandre
    Becker, Christoph
    Zaidi, Habib
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [6] Estimation of effective and organ dose from chest CT
    Almaasfeh, Sultan
    Salahudeen, Abdulrahman
    Salih, Mohammed
    Abukonna, Ahmed
    RADIATION PHYSICS AND CHEMISTRY, 2023, 204
  • [7] Organ dose in CT: Comparison between measurements and computational methods
    Pace, Martina
    Bonanno, Elisa
    Borzi, Giuseppina Rita
    Cavalli, Nina
    D'Anna, Alessia
    Gueli, Anna Maria
    Stella, Giuseppe
    Zirone, Lucia
    Marino, Camelo
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 112
  • [8] Organ Dose, Effective Dose, and Dose Conversion Coefficients in Adult CT: Comparison of Mathematical, XCAT, and ICRP Reference Phantoms
    Zhang, Y.
    Li, X.
    Segars, W.
    Samei, E.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [9] iPhantom: A Framework for Automated Creation of Individualized Computational Phantoms and Its Application to CT Organ Dosimetry
    Fu, Wanyi
    Sharma, Shobhit
    Abadi, Ehsan
    Iliopoulos, Alexandros-Stavros
    Wang, Qi
    Lo, Joseph Y.
    Sun, Xiaobai
    Segars, William P.
    Samei, Ehsan
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (08) : 3061 - 3072
  • [10] CT scanner-specific organ dose coefficients generated by Monte Carlo calculation for the ICRP adult male and female reference computational phantoms
    Jansen, Jan T. M.
    Shrimpton, Paul C.
    Edyvean, Sue
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (22):