Automatic Mapping of CT Scan Locations on Computational Human Phantoms for Organ Dose Estimation

被引:5
|
作者
Lee, Choonsik [1 ,2 ]
Kuzmin, Gleb A. [1 ]
Bae, Jinyong [3 ]
Yao, Jianhua [4 ]
Mosher, Elizabeth [1 ]
Folio, Les R. [4 ]
机构
[1] NCI, Div Canc Epidemiol & Genet, NIH, Bethesda, MD 20892 USA
[2] NCI, Radiat Epidemiol Branch, DCEG, NIH, 9609 Med Ctr Dr, Rockville, MD 20850 USA
[3] Kansas City Univ Med & Biosci, Kansas City, KS USA
[4] NIH, Radiol & Imaging Sci Clin Ctr, Bldg 10, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
Computed tomograpy; Dosimetry; Scan location; Computational human phantoms; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; ADULT; PROGRAM;
D O I
10.1007/s10278-018-0119-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To develop an algorithm to automatically map CT scan locations of patients onto computational human phantoms to provide with patient-specific organ doses. We developed an algorithm that compares a two-dimensional skeletal mask generated from patient CTs with that of a whole body computational human phantom. The algorithm selected the scan locations showing the highest Dice Similarity Coefficient (DSC) calculated between the skeletal masks of a patient and a phantom. To test the performance of the algorithm, we randomly selected five sets of neck, chest, and abdominal CT images from the National Institutes of Health Clinical Center. We first automatically mapped scan locations of the CT images on a computational human phantom using our algorithm. We had several radiologists to manually map the same CT images on the phantom and compared the results with the automated mapping. Finally, organ doses for automated and manual mapping locations were calculated by an in-house CT dose calculator and compared to each other. The visual comparison showed excellent agreement between manual and automatic mapping locations for neck, chest, and abdomen-pelvis CTs. The difference in mapping locations averaged over the start and end in the five patients was less than 1 cm for all neck, chest, and AP scans: 0.9, 0.7, and 0.9 cm for neck, chest, and AP scans, respectively. Five cases out of ten in the neck scans show zero difference between the average manual and automatic mappings. Average of absolute dose differences between manual and automatic mappings was 2.3, 2.7, and 4.0% for neck, chest, and AP scans, respectively. The automatic mapping algorithm provided accurate scan locations and organ doses compared to manual mapping. The algorithm will be useful in cases requiring patient-specific organ dose for a large number of patients such as patient dose monitoring, clinical trials, and epidemiologic studies.
引用
收藏
页码:175 / 182
页数:8
相关论文
共 50 条
  • [41] Uncertainties in Convolution-Based Organ Dose Estimation in TubeCurrent Modulated CT
    Fu, W.
    Choudhury, K.
    Kapadia, A.
    Segars, P.
    Samei, E.
    MEDICAL PHYSICS, 2017, 44 (06) : 3301 - 3301
  • [42] Patient organ and effective dose estimation in CT: comparison of four software applications
    Cristina De Mattia
    Federica Campanaro
    Federica Rottoli
    Paola Enrica Colombo
    Andrea Pola
    Angelo Vanzulli
    Alberto Torresin
    European Radiology Experimental, 4
  • [43] Patient organ and effective dose estimation in CT: comparison of four software applications
    De Mattia, Cristina
    Campanaro, Federica
    Rottoli, Federica
    Colombo, Paola Enrica
    Pola, Andrea
    Vanzulli, Angelo
    Torresin, Alberto
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [44] Convolution-based Estimation of Organ Dose in Tube Current Modulated CT
    Tian, Xiaoyu
    Segars, W. Paul
    Dixon, R. L.
    Samei, Ehsan
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [45] Organ dose calculation in CT based on scout image data and automatic image registration
    Kortesniemi, Mika
    Salli, Eero
    Seuri, Raija
    ACTA RADIOLOGICA, 2012, 53 (08) : 908 - 913
  • [46] Construction of patient-specific computational models for organ dose estimation in radiological imaging
    Xie, Tianwu
    Akhavanallaf, Azadeh
    Zaidi, Habib
    MEDICAL PHYSICS, 2019, 46 (05) : 2403 - 2411
  • [47] Organ dose and scattering dose for CT coronary angiography and calcium scoring using automatic tube current modulation
    Chan, S. W.
    Ho, Y. J.
    Tyan, Y. S.
    Tsai, H. Y.
    RADIATION MEASUREMENTS, 2013, 56 : 333 - 337
  • [48] Estimation of Mouse Organ Locations Through Registration of a Statistical Mouse Atlas With Micro-CT Images
    Wang, Hongkai
    Stout, David B.
    Chatziioannou, Arion F.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (01) : 88 - 102
  • [49] Evaluation of organ dose using size-specific dose estimation (SSDE) and related cancer risk due to chest CT scan during the COVID-19 pandemic
    Robatjazi, Mostafa
    Moayed, Mahdis
    Baghani, Hamid Reza
    Molazadeh, Mikaeil
    Shomoossi, Nematullah
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2024, 63 (01) : 27 - 37
  • [50] Evaluation of organ dose using size-specific dose estimation (SSDE) and related cancer risk due to chest CT scan during the COVID-19 pandemic
    Mostafa Robatjazi
    Mahdis Moayed
    Hamid Reza Baghani
    Mikaeil Molazadeh
    Nematullah Shomoossi
    Radiation and Environmental Biophysics, 2024, 63 : 27 - 37