Analysis of class 1 residual solvents in pharmaceuticals using headspace-programmed temperature vaporization-fast gas chromatography-mass spectrometry

被引:26
|
作者
Perez Pavon, Jose Luis [1 ]
del Nogal Sanchez, Miguel [1 ]
Fernandez Laespada, Ma Esther [1 ]
Garcia Pinto, Carmelo [1 ]
Moreno Cordero, Bernardo [1 ]
机构
[1] Univ Salamanca, Fac Ciencias Quim, Dept Quim Analit Nutr & Bromatol, E-37008 Salamanca, Spain
关键词
headspace analysis; programmed temperature vaporizers; residual solvents; contour plots;
D O I
10.1016/j.chroma.2006.12.046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive method is presented for the fast screening and determination of residual class 1 solvents (1,1-dichloroethene, 1,2-dichloroethane, 1,1,1-trichloroethane, carbon tetrachloride and benzene) in pharmaceutical products. The applicability of a headspace (HS) autosampler in combination with GC equipped with a programmed temperature vaporizer (PTV) and a MS detector is explored. Different injection techniques were compared. The benefits of using solvent vent injection instead of split or splitless-hot injection for the measurement of volatile compounds are shown: better peak shapes, better signal-to-noise ratios, and hence better detection limits. The proposed method is extremely sensitive. The limits of detection ranged from 4.9 ppt (benzene) to 7.9 ppt (1,2-dichloroethane) and precision (measured as the relative standard deviation) was equal to or lower than 12% in all cases. The method was applied to the determination of residual solvents in nine different pharmaceutical products. The analytical performance of the method shows that it is appropriate for the determination of residual class 1 solvents and has much lower detection limits than the concentration limits proposed by the International Conference on Harmonization (ICH) of Technical Requirements for the Registration of Pharmaceuticals for Human Use. The proposed method achieves a clear improvement in sensitivity with respect to conventional headspace methods due to the use of the PTV. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:123 / 130
页数:8
相关论文
共 50 条
  • [21] Use of ionic liquids as headspace gas chromatography diluents for the analysis of residual solvents in pharmaceuticals
    Nacham, Omprakash
    Ho, Tien D.
    Anderson, Jared L.
    Webster, Gregory K.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 145 : 879 - 886
  • [22] Detection of soil pollution by hydrocarbons using headspace-mass spectrometry and identification of compounds by headspace-fast gas chromatography-mass spectrometry
    Pavón, JLP
    Peña, AG
    Pinto, CG
    Cordero, BM
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1047 (01) : 101 - 109
  • [23] Field gas chromatography-mass spectrometry for fast analysis
    Makas, AL
    Troshkov, ML
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 800 (1-2): : 55 - 61
  • [24] A comparative study of the analysis of human urine headspace using gas chromatography-mass spectrometry
    Smith, S.
    Burden, H.
    Persad, R.
    Whittington, K.
    Costello, B. de Lacy
    Ratcliffe, N. M.
    Probert, C. S.
    JOURNAL OF BREATH RESEARCH, 2008, 2 (03)
  • [25] Determination of residual solvents in bulk pharmaceuticals by thermal desorption/gas chromatography/mass spectrometry
    Urakami, K
    Saito, Y
    Fujiwara, Y
    Watanabe, C
    Umemoto, K
    Godo, M
    Hashimoto, K
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2000, 48 (12) : 1894 - 1897
  • [26] Evaluation of fast gas chromatography and gas chromatography-mass spectrometry in the analysis of lipids
    Mondello, L
    Casilli, A
    Tranchida, PQ
    Costa, R
    Chiofalo, B
    Dugo, P
    Dugo, G
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1035 (02) : 237 - 247
  • [27] Polycyclic aromatic hydrocarbon emissions in diesel exhaust using gas chromatography-mass spectrometry with programmed temperature vaporization and large volume injection
    de Souza, Carolina Vieira
    Correa, Sergio Machado
    ATMOSPHERIC ENVIRONMENT, 2015, 103 : 222 - 230
  • [28] Headspace-programmed temperature vaporizer-mass spectrometry and pattern recognition techniques for the analysis of volatiles in saliva samples
    Perez Anton, Ana
    del Nogal Sanchez, Miguel
    Crisolino Pozas, Angel Pedro
    Perez Pavon, Jose Luis
    Moreno Cordero, Bernardo
    TALANTA, 2016, 160 : 21 - 27
  • [29] Determination of furan in baby foods using headspace gas chromatography-mass spectrometry
    Liu Ping
    Xue Ying
    Jin Qingzhong
    Xu Jun
    Zhang Zheng
    Wu Guohua
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (01) : 35 - 38
  • [30] Room temperature ionic liquid as matrix medium for the determination of residual solvents in pharmaceuticals by static headspace gas chromatography
    Liu, Feng-Hua
    Jiang, Ye