Analysis of class 1 residual solvents in pharmaceuticals using headspace-programmed temperature vaporization-fast gas chromatography-mass spectrometry

被引:26
|
作者
Perez Pavon, Jose Luis [1 ]
del Nogal Sanchez, Miguel [1 ]
Fernandez Laespada, Ma Esther [1 ]
Garcia Pinto, Carmelo [1 ]
Moreno Cordero, Bernardo [1 ]
机构
[1] Univ Salamanca, Fac Ciencias Quim, Dept Quim Analit Nutr & Bromatol, E-37008 Salamanca, Spain
关键词
headspace analysis; programmed temperature vaporizers; residual solvents; contour plots;
D O I
10.1016/j.chroma.2006.12.046
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive method is presented for the fast screening and determination of residual class 1 solvents (1,1-dichloroethene, 1,2-dichloroethane, 1,1,1-trichloroethane, carbon tetrachloride and benzene) in pharmaceutical products. The applicability of a headspace (HS) autosampler in combination with GC equipped with a programmed temperature vaporizer (PTV) and a MS detector is explored. Different injection techniques were compared. The benefits of using solvent vent injection instead of split or splitless-hot injection for the measurement of volatile compounds are shown: better peak shapes, better signal-to-noise ratios, and hence better detection limits. The proposed method is extremely sensitive. The limits of detection ranged from 4.9 ppt (benzene) to 7.9 ppt (1,2-dichloroethane) and precision (measured as the relative standard deviation) was equal to or lower than 12% in all cases. The method was applied to the determination of residual solvents in nine different pharmaceutical products. The analytical performance of the method shows that it is appropriate for the determination of residual class 1 solvents and has much lower detection limits than the concentration limits proposed by the International Conference on Harmonization (ICH) of Technical Requirements for the Registration of Pharmaceuticals for Human Use. The proposed method achieves a clear improvement in sensitivity with respect to conventional headspace methods due to the use of the PTV. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:123 / 130
页数:8
相关论文
共 50 条
  • [11] Rapid Monitoring and Determination of Class 1 Residual Solvents in Pharmaceuticals Using Dispersive Liquid-Liquid Microextraction and Gas Chromatography-Mass Spectrometry
    Heydari, Rouhollah
    Azizi, Saber
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (06) : 1020 - 1025
  • [12] In situ derivatization reaction and determination of ibuprofen in water samples using headspace generation-programmed temperature vaporization-gas chromatography-mass spectrometry
    Perez Pavon, Jose Luis
    Casas Ferreira, Ana Maria
    Fernandez Laespada, Maria Esther
    Moreno Cordero, Bernardo
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (39) : 6728 - 6734
  • [13] Simultaneous determination of 57 residual volatile organic solvents in honey by headspace gas chromatography-mass spectrometry
    Liu Yongming
    Ge Na
    Wang Fei
    Li Jin
    Wu Yanping
    Huang Xuezhe
    Cao Yanzhong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2012, 30 (08) : 782 - 791
  • [14] Programmed temperature vaporization injection (PTV) in the analysis by gas chromatography-mass spectrometry (GC-MS) of the constituents of landfill gas
    Junyapoon, S
    Bartle, KD
    Ross, AB
    Cooke, M
    Smethurst, BF
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2000, 77 (04) : 337 - 348
  • [15] Headspace-programmed temperature vaporization-mass spectrometry for the rapid determination of possible volatile biomarkers of lung cancer in urine
    Perez Anton, Ana
    Garcia Ramos, Alvaro
    del Nogal Sanchez, Miguel
    Perez Pavon, Jose Luis
    Moreno Cordero, Bernardo
    Crisolino Pozas, Angel Pedro
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (19) : 5239 - 5246
  • [16] Determination of aromatic and polycyclic aromatic hydrocarbons in gasoline using programmed temperature vaporization-gas chromatography-mass spectrometry
    Perez Pavon, Jose Luis
    Sanchez, Miguel del Nogal
    Fernandez Laespada, Maria Esther
    Cordero, Bernardo Moreno
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1202 (02) : 196 - 202
  • [17] Headspace-programmed temperature vaporization-mass spectrometry for the rapid determination of possible volatile biomarkers of lung cancer in urine
    Ana Pérez Antón
    Álvaro García Ramos
    Miguel del Nogal Sánchez
    José Luis Pérez Pavón
    Bernardo Moreno Cordero
    Ángel Pedro Crisolino Pozas
    Analytical and Bioanalytical Chemistry, 2016, 408 : 5239 - 5246
  • [18] Unknown residual solvents identification in drug products by headspace solid phase microextraction gas chromatography-mass spectrometry
    C. C. Camarasu
    Chromatographia, 2002, 56 : S131 - S135
  • [19] Unknown residual solvents identification in drug products by headspace solid phase microextraction gas chromatography-mass spectrometry
    Camarasu, CC
    CHROMATOGRAPHIA, 2002, 56 (1) : S131 - S135
  • [20] Determination of residual acrylate monomers in adhesives by headspace gas chromatography-mass spectrometry
    Liu Dan
    Chen Xiaoqing
    Wu Mingjian
    Li Shaoye
    Dai Yunhui
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (12) : 1179 - 1182