Reference tissue quantification of DCE-MRI data without a contrast agent calibration

被引:26
|
作者
Walker-Samuel, Simon [1 ]
Leach, Martin O.
Collins, David J.
机构
[1] Inst Canc Res, Canc Res UK Clin Magnet Resonance Res Grp, Sutton SM2 5NG, Surrey, England
[2] Royal Marsden NHS Fdn Trust, Sutton SM2 5NG, Surrey, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 03期
关键词
D O I
10.1088/0031-9155/52/3/004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The quantification of dynamic contrast- enhanced ( DCE) MRI data conventionally requires a conversion from signal intensity to contrast agent concentration by measuring a change in the tissue longitudinal relaxation rate, R-1. In this paper, it is shown that the use of a spoiled gradient- echo acquisition sequence ( optimized so that signal intensity scales linearly with contrast agent concentration) in conjunction with a reference tissue- derived vascular input function ( VIF), avoids the need for the conversion to Gd- DTPA concentration. This study evaluates how to optimize such sequences and which dynamic time-series parameters are most suitable for this type of analysis. It is shown that signal difference and relative enhancement provide useful alternatives when full contrast agent quantification cannot be achieved, but that pharmacokinetic parameters derived from both contain sources of error ( such as those caused by differences between reference tissue and region of interest proton density and native T-1 values). It is shown in a rectal cancer study that these sources of uncertainty are smaller when using signal difference, compared with relative enhancement ( 15 +/- 4% compared with 33 +/- 4%). Both of these uncertainties are of the order of those associated with the conversion to Gd- DTPA concentration, according to literature estimates.
引用
收藏
页码:589 / 601
页数:13
相关论文
共 50 条
  • [1] Incorporating contrast agent diffusion into the analysis of DCE-MRI data
    Pellerin, Martin
    Yankeelov, Thomas E.
    Lepage, Martin
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1124 - 1134
  • [2] The effects of intravoxel contrast agent diffusion on the analysis of DCE-MRI data in realistic tissue domains
    Woodall, Ryan T.
    Barnes, Stephanie L.
    Hormuth, David A., II
    Sorace, Anna G.
    Quarles, C. Chad
    Yankeelov, Thomas E.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 330 - 340
  • [3] Liver DCE-MRI registration based on sparse recovery of contrast agent curves
    Sun, Yuhang
    Zhu, Qiaoyun
    Huang, Meiyan
    Shen, Dinggang
    Zhou, Yujia
    Feng, Qianjin
    MEDICAL PHYSICS, 2021, 48 (11) : 6916 - 6929
  • [4] Estimation of Contrast Agent Concentration in DCE-MRI Using 2 Flip Angles
    Das, Ayesha Bharadwaj
    Tranos, James Andrew
    Zhang, Jin
    Wadghiri, Youssef Zaim
    Kim, Sungheon Gene
    INVESTIGATIVE RADIOLOGY, 2022, 57 (05) : 343 - 351
  • [5] Quantitative pharmacokinetic analysis of DCE-MRI data without an arterial input function: a reference region model
    Yankeelov, TE
    Luci, JJ
    Lepage, M
    Li, R
    Debusk, L
    Lin, PC
    Price, RR
    Gore, JC
    MAGNETIC RESONANCE IMAGING, 2005, 23 (04) : 519 - 529
  • [6] Model selection for analysis of dynamic contrast enhanced MRI (DCE-MRI) data.
    Yankeelov T
    Welch E B
    Chakravarthy B
    Lee R
    Freehardt D
    Mayer, I
    Meszoely, I
    Kelly M
    Means-Powell J
    Gore J
    BREAST CANCER RESEARCH AND TREATMENT, 2007, 106 : S45 - S45
  • [7] The use of a reference tissue arterial input function with low-temporal-resolution DCE-MRI data
    Heisen, M.
    Fan, X.
    Buurman, J.
    van Riel, N. A. W.
    Karczmar, G. S.
    Romeny, B. M. ter Haar
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (16): : 4871 - 4883
  • [8] Quantification of Antiangiogenic and Antivascular Drug Activity by Kinetic Analysis of DCE-MRI Data
    Ferl, G. Z.
    Port, R. E.
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2012, 92 (01) : 118 - 124
  • [9] A synthetic phantom for quality assessment of DCE-MRI quantification
    Chao, S. L.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S22 - S22
  • [10] A Constrained Linear Reference Region Model For DCE-MRI
    Ahmed, Z.
    El Naqa, I.
    Levesque, I. R.
    MEDICAL PHYSICS, 2015, 42 (06) : 3735 - 3735