Hydrogen bond based recognition of nucleotides by neutral-carrier ion-selective electrodes

被引:45
|
作者
Amemiya, S [1 ]
Buhlmann, P [1 ]
Tohda, K [1 ]
Umezawa, Y [1 ]
机构
[1] UNIV TOKYO,SCH SCI,DEPT CHEM,BUNKYO KU,TOKYO 113,JAPAN
关键词
ion-selective electrodes; nucleotides;
D O I
10.1016/S0003-2670(96)00626-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric responses of solvent polymeric membrane electrodes for nucleotides based on neutral derivatives of cytosine and thymine have been investigated. Nernstian responses to the 5'monophosphates of guanosine (5'GMP) and adenosine (5'AMP) in their divalent forms are obtained when these membranes contain an ionophore and lipophilic cationic sites. Independent interaction of the ionophore and ionic sites with two different functional groups of the analyte ion allows ditopic recognition based on hydrogen bonds and charge-charge interactions. Selectivity for 5'GMP over 5'AMP is obtained with electrodes based on cytosine derivatives while an electrode based on a thymine derivative shows no such discrimination. These electrodes represent the first cases of ion-selective electrodes (ISEs) with Nernstian slopes in which potentiometric selectivities are due to the formation of hydrogen bonds between a neutral ionophore and a neutral moiety of the analyte. Because the emf response slopes are Nernstian, it is possible to interpret the emf responses on the basis of phase boundary equilibria. The potentiometric selectivities seem to be affected by ionophore solvation and self-assembly involving hydrogen bonds as well as by formation of analyte-ionophore complexes of higher stoichiometry, as shown by C-13 NMR spectroscopy of PVC membranes and by variation of the ratio between ionophore and added cationic sites.
引用
收藏
页码:129 / 139
页数:11
相关论文
共 50 条
  • [41] THIN-FILM ION-SELECTIVE SENSORS BASED ON NEUTRAL CARRIER MEMBRANES
    KEPLINGER, F
    GLATZ, R
    JACHIMOWICZ, A
    URBAN, G
    KOHL, F
    OLCAYTUG, F
    PROHASKA, OJ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) : 272 - 274
  • [42] NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODE FOR INTRACELLULAR MAGNESIUM ACTIVITY STUDIES
    LANTER, F
    ERNE, D
    AMMANN, D
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1980, 52 (14) : 2400 - 2402
  • [43] ION-EXCHANGE AT NEUTRAL CARRIER ION-SELECTIVE ELECTRODE MEMBRANES
    HORVATH, V
    HORVAI, G
    PUNGOR, E
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1993, 346 (6-9): : 569 - 571
  • [44] NEUTRAL-CARRIER-BASED ION-SELECTIVE MICROELECTRODES DESIGN AND APPLICATION - A REVIEW
    BUHRER, T
    GEHRIG, P
    SIMON, W
    [J]. ANALYTICAL SCIENCES, 1988, 4 (06) : 547 - 557
  • [45] POLYVINYL-CHLORIDE) MATRIX MEMBRANE URANYL ION-SELECTIVE ELECTRODES BASED ON CYCLIC AND ACYCLIC NEUTRAL CARRIER SENSORS
    JOHNSON, S
    MOODY, GJ
    THOMAS, JDR
    KOHNKE, FH
    STODDART, JF
    [J]. ANALYST, 1989, 114 (09) : 1025 - 1028
  • [46] Ion-selective electrodes:: Polyaniline modification and anion recognition
    Shishkanova, TV
    Sapurina, I
    Stejskal, J
    Král, V
    Volf, R
    [J]. ANALYTICA CHIMICA ACTA, 2005, 553 (1-2) : 160 - 168
  • [47] NEW RECOGNITION AND RESPONSE MECHANISMS OF ION-SELECTIVE ELECTRODES
    UMEZAWA, Y
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 210 : 12 - ANYL
  • [48] SELECTIVE ION-EXCHANGER BEHAVIOR OF NEUTRAL CARRIER ION-SELECTIVE ELECTRODE MEMBRANES
    HORVAI, G
    HORVATH, V
    FARKAS, A
    PUNGOR, E
    [J]. TALANTA, 1989, 36 (03) : 403 - 405
  • [49] NEUTRAL CARRIER SODIUM ION-SELECTIVE MICROELECTRODE FOR EXTRACELLULAR STUDIES
    AMMANN, D
    ANKER, P
    [J]. NEUROSCIENCE LETTERS, 1985, 57 (03) : 267 - 271
  • [50] ION-SELECTIVE ELECTRODES
    MEYERHOFF, ME
    FRATICELLI, YM
    [J]. ANALYTICAL CHEMISTRY, 1982, 54 (05) : R27 - R44