Hydrogen bond based recognition of nucleotides by neutral-carrier ion-selective electrodes

被引:45
|
作者
Amemiya, S [1 ]
Buhlmann, P [1 ]
Tohda, K [1 ]
Umezawa, Y [1 ]
机构
[1] UNIV TOKYO,SCH SCI,DEPT CHEM,BUNKYO KU,TOKYO 113,JAPAN
关键词
ion-selective electrodes; nucleotides;
D O I
10.1016/S0003-2670(96)00626-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric responses of solvent polymeric membrane electrodes for nucleotides based on neutral derivatives of cytosine and thymine have been investigated. Nernstian responses to the 5'monophosphates of guanosine (5'GMP) and adenosine (5'AMP) in their divalent forms are obtained when these membranes contain an ionophore and lipophilic cationic sites. Independent interaction of the ionophore and ionic sites with two different functional groups of the analyte ion allows ditopic recognition based on hydrogen bonds and charge-charge interactions. Selectivity for 5'GMP over 5'AMP is obtained with electrodes based on cytosine derivatives while an electrode based on a thymine derivative shows no such discrimination. These electrodes represent the first cases of ion-selective electrodes (ISEs) with Nernstian slopes in which potentiometric selectivities are due to the formation of hydrogen bonds between a neutral ionophore and a neutral moiety of the analyte. Because the emf response slopes are Nernstian, it is possible to interpret the emf responses on the basis of phase boundary equilibria. The potentiometric selectivities seem to be affected by ionophore solvation and self-assembly involving hydrogen bonds as well as by formation of analyte-ionophore complexes of higher stoichiometry, as shown by C-13 NMR spectroscopy of PVC membranes and by variation of the ratio between ionophore and added cationic sites.
引用
收藏
页码:129 / 139
页数:11
相关论文
共 50 条
  • [21] BARIUM ION-SELECTIVE ELECTRODE BASED ON A NEUTRAL CARRIER COMPLEX
    LEVINS, RJ
    [J]. ANALYTICAL CHEMISTRY, 1972, 44 (08) : 1544 - &
  • [22] Lead ion-selective electrode based on a neutral mobile carrier
    Marin, LP
    Rubi, YM
    de Fuentes, OA
    Ortiz, OF
    Sanchez, EO
    Estevez, OL
    Fajardo, Y
    Chamorro, JA
    Casabo, J
    [J]. AFINIDAD, 1998, 55 (474) : 130 - 132
  • [23] IMPROVED CALCIUM ION-SELECTIVE ELECTRODE BASED ON A NEUTRAL CARRIER
    AMMANN, D
    GUGGI, M
    PRETSCH, E
    SIMON, W
    [J]. ANALYTICAL LETTERS, 1975, 8 (10) : 709 - 720
  • [24] WATER HARDNESS ION-SELECTIVE ELECTRODE BASED ON A NEUTRAL CARRIER
    HU, ZM
    QI, DY
    [J]. ANALYTICA CHIMICA ACTA, 1991, 248 (01) : 177 - 181
  • [25] BARIUM ION-SELECTIVE ELECTRODE BASED ON A NEW NEUTRAL CARRIER COMPLEX
    BOUKLOUZE, AA
    VIRE, JC
    COOL, V
    [J]. ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) : 153 - 163
  • [26] STUDY OF CALCIUM ION-SELECTIVE ELECTRODE BASED ON A NEW NEUTRAL CARRIER
    Wei XU Bin GUO You Rong NIE Zai Fu HUANG Department of Environmental Science
    [J]. Chinese Chemical Letters, 1993, (02) : 179 - 180
  • [27] Silver ion-selective electrodes based on bis(dialkyldithiocarbamates) as neutral ionophores
    Yan, Zhenning
    Lu, Yanqi
    Li, Xia
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (01) : 174 - 181
  • [28] Selectivity of carrier-based ion-selective electrodes: Is the problem solved?
    Bakker, E
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (05) : 252 - 260
  • [29] IONIC SITES FOR CHARGED-CARRIER-BASED ION-SELECTIVE ELECTRODES
    SCHALLER, U
    BAKKER, E
    PRETSCH, E
    [J]. ACH-MODELS IN CHEMISTRY, 1994, 131 (06): : 739 - 759
  • [30] Potentiometric characteristics of ion-selective electrodes based on upper-rim calix[4]crown neutral carrier
    Kang, YR
    Oh, HJ
    Lee, KM
    Cha, GS
    Nam, H
    Paek, K
    Ihm, H
    [J]. BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 1998, 19 (02) : 207 - 211